50 resultados para automated external defibrillators
em Scielo Saúde Pública - SP
Resumo:
After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.
Resumo:
Cardiopulmonary arrest is a medical emergency in which the lapse of time between event onset and the initiation of measures of basic and advanced support, as well as the correct care based on specific protocols for each clinical situation, constitute decisive factors for a successful therapy. Cardiopulmonary arrest care cannot be restricted to the hospital setting because of its fulminant nature. This necessitates the creation of new concepts, strategies and structures, such as the concept of life chain, cardio-pulmonary resuscitation courses for professionals who work in emergency medical services, the automated external defibrillator, the implantable cardioverter-defibrillator, and mobile intensive care units, among others. New concepts, strategies and structures motivated by new advances have also modified the treatment and improved the results of cardiopulmonary resuscitation in the hospital setting. Among them, we can cite the concept of cerebral resuscitation, the application of the life chain, the creation of the universal life support algorithm, the adjustment of drug doses, new techniques - measure of the end-tidal carbon dioxide levels and of the coronary perfusion pressure - and new drugs under research.
Resumo:
Background:Despite being recommended as a compulsory part of the school curriculum, the teaching of basic life support (BLS) has yet to be implemented in high schools in most countries.Objectives:To compare prior knowledge and degree of immediate and delayed learning between students of one public and one private high school after these students received BLS training.Methods:Thirty students from each school initially answered a questionnaire on cardiopulmonary resuscitation (CPR) and use of the automated external defibrillator (AED). They then received theoretical-practical BLS training, after which they were given two theory assessments: one immediately after the course and the other six months later.Results:The overall success rates in the prior, immediate, and delayed assessments were significantly different between groups, with better performance shown overall by private school students than by public school students: 42% ± 14% vs. 30.2% ± 12.2%, p = 0.001; 86% ± 7.8% vs. 62.4% ± 19.6%, p < 0.001; and 65% ± 12.4% vs. 45.6% ± 16%, p < 0.001, respectively. The total odds ratio of the questions showed that the private school students performed the best on all three assessments, respectively: 1.66 (CI95% 1.26-2.18), p < 0.001; 3.56 (CI95% 2.57-4.93), p < 0.001; and 2.21 (CI95% 1.69-2.89), p < 0.001.Conclusions:Before training, most students had insufficient knowledge about CPR and AED; after BLS training a significant immediate and delayed improvement in learning was observed in students, especially in private school students.
Resumo:
Although Brazil has traditionally been characterized by a culture of inward-looking policy making, the presence of foreign firms in the Brazilian productive sector has always been significant. The share of foreign-owned firms is one of the highest that can be found among developing countries. This article discusses the main features of the external sector of the Brazilian economy, regarding trade flows, foreign investment, the internationalization of Brazilian entrepreneurial groups and the short-term financial requirements in foreign currencies
Resumo:
With the purpose of at lowering costs and reendering the demanded information available to users with no access to the internet, service companies have adopted automated interaction technologies in their call centers, which may or may not meet the expectations of users. Based on different areas of knowledge (man-machine interaction, consumer behavior and use of IT) 13 propositions are raised and a research is carried out in three parts: focus group, field study with users and interviews with experts. Eleven automated service characteristics which support the explanation for user satisfaction are listed, a preferences model is proposed and evidence in favor or against each of the 13 propositions is brought in. With balance scorecard concepts, a managerial assessment model is proposed for the use of automated call center technology. In future works, the propositions may become verifiable hypotheses through conclusive empirical research.
Resumo:
INTRODUCTION: The correct identification of the underlying cause of death and its precise assignment to a code from the International Classification of Diseases are important issues to achieve accurate and universally comparable mortality statistics These factors, among other ones, led to the development of computer software programs in order to automatically identify the underlying cause of death. OBJECTIVE: This work was conceived to compare the underlying causes of death processed respectively by the Automated Classification of Medical Entities (ACME) and the "Sistema de Seleção de Causa Básica de Morte" (SCB) programs. MATERIAL AND METHOD: The comparative evaluation of the underlying causes of death processed respectively by ACME and SCB systems was performed using the input data file for the ACME system that included deaths which occurred in the State of S. Paulo from June to December 1993, totalling 129,104 records of the corresponding death certificates. The differences between underlying causes selected by ACME and SCB systems verified in the month of June, when considered as SCB errors, were used to correct and improve SCB processing logic and its decision tables. RESULTS: The processing of the underlying causes of death by the ACME and SCB systems resulted in 3,278 differences, that were analysed and ascribed to lack of answer to dialogue boxes during processing, to deaths due to human immunodeficiency virus [HIV] disease for which there was no specific provision in any of the systems, to coding and/or keying errors and to actual problems. The detailed analysis of these latter disclosed that the majority of the underlying causes of death processed by the SCB system were correct and that different interpretations were given to the mortality coding rules by each system, that some particular problems could not be explained with the available documentation and that a smaller proportion of problems were identified as SCB errors. CONCLUSION: These results, disclosing a very low and insignificant number of actual problems, guarantees the use of the version of the SCB system for the Ninth Revision of the International Classification of Diseases and assures the continuity of the work which is being undertaken for the Tenth Revision version.
Resumo:
To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.
Resumo:
Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.
Resumo:
INTRODUCTION: Although many countries have improved vaccination coverage in recent years, some, including Guinea-Bissau, failed to meet expected targets. This paper tries to understand the main barriers to better vaccination coverage in the context of the GAVI-Alliance (The Global Alliance for Vaccines and Immunisation) cash-based support provided to Guinea-Bissau. METHODS: The analysis is based on a document analysis and a three round Delphi study with a final consensus meeting. RESULTS: Consensus attributed about 25% of the failure to perform better to implementation problems; and about 10% to governance and also 10% to scarce resources. The qualitative analysis validates the importance of implementation issues and upgraded the relevance of the human resources crisis as an important drawback. The recommendations were balanced in their upstream-downstream focus but were blind to health information issues and logistical difficulties. CONCLUSIONS: It is commendable that such a fragile state, with all sorts of barriers, manages to sustain a slow steady growth of its vaccination coverage. Not reaching the targets set reflects the inappropriateness of those targets rather than a lack of commitment of the health workforce. In the unstable context of countries such as Guinea-Bissau, the predictability of the funds from global health initiatives like the GAVI-Alliance seem to make all the difference in achieving small consistent health gains even in the presence of other major bottlenecks.
Resumo:
INTRODUCTION: Enterobacteriaceae strains are a leading cause of bloodstream infections (BSI). The aim of this study is to assess differences in clinical outcomes of patients with BSI caused by Enterobacteriaceae strains before and after introduction of an automated microbiologic system by the microbiology laboratory. METHODS: We conducted a retrospective cohort study aimed to evaluate the impact of the introduction of an automated microbiologic system (Phoenix(tm) automated microbiology system, Becton, Dickinson and Company (BD) - Diagnostic Systems, Sparks, MD, USA) on the outcomes of BSIs caused by Enterobacteriaceae strains. The study was undertaken at Hospital São Paulo, a 750-bed teaching hospital in São Paulo, Brazil. Patients with BSI caused by Enterobacteriaceae strains before the introduction of the automated system were compared with patients with BSI caused by the same pathogens after the introduction of the automated system with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. RESULTS: We evaluated 90 and 106 patients in the non-automated and automated testing periods, respectively. The most prevalent species in both periods were Klebsiella spp. and Proteus spp. Clinical cure/improvement occurred in 70% and 67.9% in non-automated and automated period, respectively (p=0.75). 14-day mortality rates were 22.2% and 30% (p=0.94) and 28-day mortality rates were 24.5% and 40.5% (p= 0.12). There were no significant differences between the two testing periods with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. CONCLUSIONS: Introduction of the BD Phoenix(tm) automated microbiology system did not impact the clinical outcomes of BSIs caused by Enterobacteriaceae strains in our setting.
Resumo:
INTRODUCTION : In 2011, the Brazilian Ministry of Health rolled out a program for the external quality assessment of rapid human immunodeficiency virus (HIV) tests using the dried tube specimen (DTS) method (EQA-RT/DTS-HIV). Our objective was to evaluate the implementation of this program at 71 voluntary counseling and testing centers (VCTCs) in the Brazilian Legal Amazonian area one year after its introduction. METHODS : Quantitative and qualitative study that analyzed secondary data and interviews with healthcare workers (HCWs) (n=39) and VCTC coordinators (n=32) were performed. The assessment used 18 key indicators to evaluate the three dimensions of the program's logical framework: structure, process, and result. Each indicator was scored from 1-4, and the aggregate results corresponding to the dimensions were expressed as proportions. The results were compared to the perceptions of the HCWs and coordinators regarding the EQA-RT/DTS-HIV program. RESULTS: The aggregate scores for the three dimensions of structure, process, and result were 91.7%, 78.6%, and 95%, respectively. The lowest score in each dimension corresponded to a different indicator: access to Quali-TR online system 39% (structure), registration in Quali-TR online system 38.7% (process), and VCTC completed the full process in the program's first round 63.4% (result). Approximately 36% of the HCWs and 52% of the coordinators reported enhanced trust in the program for its rapid HIV testing performance. CONCLUSIONS: All three program dimensions exhibited satisfactory results (>75%). Nevertheless, the study findings highlight the need to improve certain program components. Additionally, long-term follow-ups is needed to provide a more thorough picture of the process for external quality assessment.
Resumo:
OBJECTIVE: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. METHODS: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. RESULTS: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. CONCLUSION: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
OBJECTIVE - To investigate the initial energy level required for electrical cardioversion of atrial fibrillation (AF). METHODS - We studied patients undergoing electrical cardioversion in the 1st Multicenter Trial of SOCESP. Patients were divided into 2 groups according to the initial energy level of electrical cardioversion: 100J and > or = 150J. We compared the efficacy of the initial and final shock of the procedure, the number of shocks administered, and the cumulative energy levels. RESULTS - Eight-six patients underwent electrical cardioversion. In 53 patients (62%), cardioversion was started with 100J, and in 33 patients (38%), cardioversion was started with > or = 150J. Groups did not differ regarding clinical features and therapeutical interventions. A tendency existed towards greater efficacy of the initial shock in patients who received > or = 150J (61% vs. 42% in the 100J group, p=0.08). The number of shocks was smaller in the > or = 150J group (1.5±0.7 vs. 2.1±1.3, p=0.04). No difference existed regarding the final efficacy of electrical cardioversion and total cumulative energy levels in both groups. In the subgroup of patients with recent-onset AF (<=48h), the cumulative energy level was lower in the 100J group (240±227J vs. 324±225J, p=0.03). CONCLUSION - Patients who were given initial energy of > or = 150J received fewer counter shocks with a tendency toward greater success than those patients who were given 100J; however, in patients with recent-onset AF, the average cumulative energy level was lower in the 100J group. These data suggest that electrical cardioversion should be initiated with energy levels > or = 150J in patients with chronic AF.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.