19 resultados para Welding automation
em Scielo Saúde Pública - SP
Resumo:
The aim of this work was to propose, apply and evaluate a methodical approach to select welding processes in a productive environment based on market requirements of Quality and Costs. A case study was used. The welds were carried out in laboratory, simulating the joint conditions of a manufacturer and using several welding processes: SMAW, GTAW, pulsed GTAW, GMAW with CO2 and Ar based shielding gases and pulsed GMAW. For Quality analysis geometrical aspects of the beads were considered and for Cost analysis, welding parameters and consumable prices. Quantitative indices were proposed and evaluated. After that, evaluation of both Quality and Costs was done, showing to be possible to select the most suitable welding process to a specific application, taking into account the market conditions of a company.
Resumo:
The application of flux cored arc welding (FCAW) has increased in manufacturing and fabrication. Even though FCAW is well known for its good capability in producing quality welds, few reports have been published on the cause of the relatively high diffusible hydrogen content in the weld metal and its relation with the ingredients used in the wire production and with the welding parameters (mainly welding current). This paper describes experiments where data obtained from weld metal diffusible hydrogen analysis, metal droplet collection, and high-speed recording of metal droplet transfer were used to evaluate the effect of welding current on diffusible hydrogen content in the weld metal. The results from gas chromatography analysis showed that weld metal hydrogen content indeed increased with welding current. A polynomial regressional analysis concluded that hydrogen increase with current was better described by a linear function with proportional constant of approximately 0.7 or 70%. Different from the GMA welding transfer behavior, statistical analysis showed only a small increase in metal droplet size with increasing current. The metal transfer mode remained in the globular range for currents between 100 and 150 A. The most surprising findings were with the high-speed cinematography recording. Observing the high speed movies, it was possible to see that at low current, "unmelted" flux sporadically touched the weld pool but at higher current, the flux remained touching the weld pool during the whole time of droplet formation and transfer. It is believed that since the flux has ingredients that contain hydrogen, hydrogen passes through the arc undisturbed, going to the weld bead intact and increasing the hydrogen content in the weld metal. Another important observation is regarding to droplet size. Droplet size increased with increasing current because forces from decomposed gases from the flux could sustain the droplets, retarding their transfer and allowing them to grow.
Resumo:
Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.
Resumo:
INTRODUCTION: The aim of the present study was to identify the presence of Leishmania (Leishmania) chagasi infection in dogs in the City of Palmas, Tocantins, Brazil, using the PCR technique to list the hot spots of infected dogs in the city and associate their occurrence to significant environmental changes at capture sites. METHODS: DNA was extracted from blood of dogs, and the PCR were performed with primers RV1/RV2. After screening the population studied, the regions of the city that had the highest occurrence of canine infection were detected. These sites were visited, and ecological parameters denoting anthropogenic disturbance were evaluated. RESULTS: Some important features were listed in the regions visited, such as low urbanization, lack of public collection of sewage, limited garbage collection, vacant lots with tall vegetation, decaying organic matter, and, most importantly, the occurrence of stray dogs and poultry in homes. CONCLUSIONS: The methodology for screening the population was very efficient, especially in evaluating a large number of individuals in a short time, with a high degree of automation. The results indicate an association between the observed parameters and the occurrence of infection in dogs. The model presented in the city is ideal for studies of disease progression and expansion and for the evaluation of control measures adopted for canine VL.
Resumo:
The high sensitivity and the possibility of automation of the enzyme-linked-immunosorbent-assay (ELISA) has indicated this technique as one of the most useful serological test for epidemiological studies. In the present study, an ELISA for detection of IgG antibodies against adult worm antigens (IgG-ELISA) was investigated for epidemiological purposes, in a rural area of the municipality of Itariri (São Paulo, Brazil). Blood on filter paper (1,180 samples) from about 650 schoolchildren were submitted to ELISA and the data compared to the results of the parasitological method of Kato-Katz and also to the IgM-IFT (immunofluorescence test for IgM antibodies to gut associated antigens). The prevalence rates respectively of 8.5%, 43.0%, and 56.2% by the Kato-Katz, IgG-ELISA, and IgM-IFT methods suggest the poor sensitivity of the parasitological method for detection of Schistosoma mansoni eggs in individuals with low worm burden, situation commonly observed in low endemic areas. These results can partially explain the poor degree of agreement between the IgG-ELISA and the Kato-Katz, as suggested by the Kappa index of 0.170. Otherwise, the Kappa index of 0.675 showed substantial agreement between the two serological tests. Some discrepancy of results between the two serological techniques must be better investigated.
Resumo:
Soil penetration resistance (PR) and the tensile strength of aggregates (TS) are commonly used to characterize the physical and structural conditions of agricultural soils. This study aimed to assess the functionality of a dynamometry apparatus by linear speed and position control automation of its mobile base to measure PR and TS. The proposed equipment was used for PR measurement in undisturbed samples of a clayey "Nitossolo Vermelho eutroférrico" (Kandiudalfic Eutrudox) under rubber trees sampled in two positions (within and between rows). These samples were also used to measure the volumetric soil water content and bulk density, and determine the soil resistance to penetration curve (SRPC). The TS was measured in a sandy loam "Latossolo Vermelho distrófico" (LVd) - Typic Haplustox - and in a very clayey "Nitossolo Vermelho distroférrico" (NVdf) - Typic Paleudalf - under different uses: LVd under "annual crops" and "native forest", NVdf under "annual crops" and "eucalyptus plantation" (> 30 years old). To measure TS, different strain rates were applied using two dynamometry testing devices: a reference machine (0.03 mm s-1), which has been widely used in other studies, and the proposed equipment (1.55 mm s-1). The determination coefficient values of the SRPC were high (R² > 0.9), regardless of the sampling position. Mean TS values in LVd and NVdf obtained with the proposed equipment did not differ (p > 0.05) from those of the reference testing apparatus, regardless of land use and soil type. Results indicate that PR and TS can be measured faster and accurately by the proposed procedure.
Resumo:
The study assessed growth and physiological parameters of 'Sunrise Golden' and 'Tainung 01' papaya seedlings grown in 280mL plastic tubes and watered using a low-cost automatic irrigation system adjusted to operate at substrate water tension for starting irrigation (STI) of 3.0, 6.0 or 9.0 kPa. The water depths applied by the dripping system and drainage were monitored during germination and seedling growth. Germination, emergence velocity index (EVI), leaf area, plant height, shoot and root dry weight, stomatal conductance, relative water content (RWC) and relative chlorophyll content (RCC) were evaluated. Soil nutrient levels were determined by electrical conductivity (EC). Water use efficiency (WUE) corresponded to the ratio of plant dry mass to depth of water applied. STI settings did not affect papaya germination or EVI. System configuration to 3.0 and 6.0 kPa STI exhibited the highest drainage and lowest EC and RCC, indicating soil nutrient loss and plant nutrient deficiency. Drainage was greater in tubes planted with the 'Tainung 01' variety, which developed smaller root systems and lower stomatal conductance than 'Sunrise Golden' seedlings. The highest values for shoot dry weight and WEU were obtained at 6.0 kPa STI for 'Sunrise Golden' (0.62 g and 0.69 g L-1) and at 9.0 kPa in 'Tainung 01' (0.35 g and 0.82 g L-1). RWC at 9.0 kPa STI was lower than at 3.0 kPa in both varieties. The results indicate that the low-cost technology developed for irrigation automation is promising. Even so, new studies are needed to evaluate low-flow irrigation systems as well as the nutrient and water needs of different papaya varieties.
Resumo:
A simple and inexpensive device to automate a water distilling apparatus is shown. It is composed by a magnetic floater placed in the water reservoir and a level control unit, which acts over the heating element circuit. In order to provide water saving, an electromagnetic valve is inserted in the water supply inlet. Some suggestions for the adaptation to other types of equipment are also offered.
Resumo:
A new automated system for acid-base flow titrations is proposed. In the operation mode, several sample to titrant volumetric ratios are injected in an air segmented plug. Five three way solenoid valves and three acrilic junctions, assembled in a hidrodynamic injection system, were accountable for the monosegmented reagents plug formation. A turbulent flow reactor was used for a perfect mix of reagents in the plug. The detector system employed a glass combined electrode fitted in an acrilic holder. Titrations of hydrochloric, nitric and acetic acids, in several concentrations, were performed with standard sodium hidroxide, for evaluation of the efficiency of the system. The relative standard deviation of the determinations was about ±0,5% and each titration was carried out in 3-4 minutes. A Quick BASIC 4.5® program was developed for the titrator control.
Resumo:
This paper presents the design of a simple apparatus that periodically switches off both working and auxiliary electrodes short-circuiting them for a couple of seconds. Depolarization takes place and the initial current is re-established.
Resumo:
This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.
Resumo:
An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).
Resumo:
Isotopic and elemental analysis of N, C and S in liquid and solid samples has been simplified with the advent of automated systems. The simplest method of automation for this kind of analysis involves an elemental analyzer interfaced directly to the ion source of an IRMS (Isotope Ratio Mass Spectrometry). In the analyzer reduction system, an expressive amount of oxidized copper is generated as solid residue. This material is normally imported and the price is very high. A methodology was proposed for the recovery of metallic copper in order to recycle this reagent in the reduction system of a GC-IRMS, using the hydrogen gas in the vacuum line. Results show that it is possible to obtain a recycle of about 95 % of the initial metallic copper used in the reduction system.
Resumo:
This study concerns certain problems inherent to the determination of fat-soluble vitamins in food, from extraction methods to identification and quantification. The discussion involves the main official and unofficial extraction methods coupled with spectrophotometric and HPLC techniques in which vitamins samples are obtained through liquid-liquid-solid and liquid-liquid-solid-solid extraction, indispensable to the analytical separation of different chemical compounds with vitamin functions. A saponification stage, possibly coupled with supercritical fluid extraction appears to be mandatory in the determination of vitamins A and E in their alcoholic forms. Alternative identification and quantification procedures are outlined: biological and chemical assays, analytical separations by HPLC (normal and reversed-phase), UV detection (all fat-soluble vitamins) and fluorescence detection (retinoids and tocopherols). Automation from sample preparation to quantification stages increases the data acquisition rate.
Resumo:
European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.