34 resultados para Wave plate
em Scielo Saúde Pública - SP
Resumo:
The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.
Resumo:
Prevalence of Strongyloides stercoralis infection in three areas of Brazil was surveyed by a recently developed faecal culture method (an agar plate culture). The Strongyloides infection was confirmed in 11.3% of 432 subjects examined. The diagnostic efficacy of the agar plate culture was as high as 93.9% compared to only 28.5% and 26.5% by the Harada-Mori filter paper culture and faecal concentration methods, when faecal samples were examined simultaneously by these three methods. Among the 49 positive samples, about 60% were confirmed to be positive only by the agar plate culture. These results indicate that the agar plate culture is a sensitive new tool for the correct diagnosis of chronic Strongyloides infection.
Resumo:
OBJECTIVE: To assess the relation between P-wave and QT dispersions in elderly patients with heart failure. METHODS: Forty-seven elderly patients (75.6±6 years) with stable heart failure in NYHA functional classes II or III and with ejection fractions of 37±6% underwent body surface mapping to analyze P-wave and QT dispersions. The degree of correlation between P-wave and QT dispersions was assessed, and P-wave dispersion values in patients with QT dispersion greater than and smaller than 100 ms were compared. RESULTS: The mean values of P-wave and QT dispersions were 54±14 ms and 68±27 ms, respectively. The correlation between the 2 variables was R=0.41 (p=0.04). In patients with QT dispersion values > 100 ms, P-wave dispersion was significantly greater than in those with QT dispersion values < 100 ms (58±16 vs 53±12 ms, p=0.04 ). CONCLUSION: Our results suggest that, in elderly patients with heart failure, a correlation between the values of P-wave and QT dispersions exists. These findings may have etiopathogenic, pathophysiologic, prognostic, and therapeutic implications, which should be investigated in other studies.
Resumo:
Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.
Resumo:
The marsupial and placental mammals originated at a time when the pattern of geographical barriers (oceans, shallow seas and mountains) was very different from that of today, and climates were warmer. The sequence of changes in these barriers, and their effects on the dispersal of the mammal families and on the faunas of mammals in the different continents, are reviewed. The mammal fauna of South America changed greatly in the Pliocene/Pleistocene, when the newly-complete Panama Isthmus allowed the North American fauna to enter the continent and replace most of the former South American mammal families. Marsupial, but not placental, mammals reached Australia via Antarctica before Australia became isolated, while rats and bats are the only placentals that dispersed naturally from Asia to Australia in the late Cenozoic. Little is known of the early history of the mammal fauna of India. A few mammal families reached Madagascar from Africa in the early Cenozoic over a chain of islands. Africa was isolated for much of the early Cenozoic, though some groups did succeed in entering from Europe. Before the climate cooled in the mid-Cenozoic, the mammal faunas of the Northern Hemisphere were much richer than those of today.
Resumo:
Direct smear examination using Ziehl-Neelsen staining for pulmonary tuberculosis (PTB) diagnosis is inexpensive and easy to use, but has the major limitation of low sensitivity. Rapid molecular methods are becoming more widely available in centralized laboratories, but they depend on timely reporting of results and strict quality assurance obtainable only from costly commercial kits available in high burden nations. This study describes a pre-commercial colorimetric method, Detect-TB, for detecting Mycobacterium tuberculosis DNA in which an oligonucleotide probe is fixed onto wells of microwell plates and hybridized with biotinylated polymerase chain reaction amplification products derived from clinical samples. The probe is capable of hybridising with the IS6110 insertion element and was used to specifically recognise the M. tuberculosis complex. When combined with an improved silica-based DNA extraction method, the sensitivity of the test was 50 colony-forming units of the M. tuberculosis reference strain H37Rv. The results that were in agreement with reference detection methods were observed in 95.2% (453/476) of samples included in the analysis. Sensitivity and specificity for 301 induced sputum samples and 175 spontaneous sputum samples were 85% and 98%, and 94% and 100%, respectively. This colorimetric method showed similar specificity to that described for commercially available kits and may provide an important contribution for PTB diagnosis.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl)) in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996) for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.
Resumo:
This work presents an electroanalytical method for the determination of moxifloxacin (MOXI) in tablets by its interaction with Cu(II) ion and subsequent electrochemical reduction at hanging mercury drop electrode (HMDE). A well-defined reduction peak at -0.21 V vs. Ag/AgCl in Phosphate buffer 0.04 mol L-1 pH 8.0 was observed for the complex reduction MOXI-Cu(II), using square-wave voltammetry (SWV). Using a 10 s of accumulation time at -0.40 V was found a limit detection of 3.60x10-8 mol l-1. The obtained results have shown good agreement with those obtained by spectrophotometric method.
Resumo:
In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.
Resumo:
As vigas estruturais de madeira são formas racionais do emprego da madeira na construção de estruturas, sendo obtidas pela associação de peças serradas e permitindo a utilização de tábuas com seções e comprimentos variados, além de combinações com madeira de qualidade diferenciada. Para atingir a resistência máxima de uma viga de madeira laminada colada, pode-se utilizar a classificação mecânica das peças por meio dinâmico. O objetivo deste estudo foi estabelecer correlação entre os métodos estático e dinâmico de classificação de vigas de madeira laminada. O trabalho foi desenvolvido com o emprego de peças de madeira serrada de Pinus taeda e adesivo resorcina fenolformaldeído. O processo de fabricação das vigas envolveu a classificação das peças, usinagem de emendas, formação das lamelas, montagem e prensagem das vigas. Já os ensaios envolveram a determinação do módulo de elasticidade por meio do ''stress wave method'' e de uma máquina universal de ensaios. Os resultados foram analisados pela análise de regressão do estabelecimento da equação de ajuste de correlação. O sistema de classificação visual utilizado na seleção de peças foi insuficiente para se atingirem os valores máximos de módulo de elasticidade; o posicionamento correto das lamelas por meio do método dinâmico de classificação teve como consequência direta o aumento do módulo de elasticidade da viga, e houve baixa correlação entre as formas de obtenção do módulo de elasticidade das vigas, não sendo possível a elaboração de equação adequada entre os métodos testados.
Resumo:
Foram avaliadas as propriedades físicas e mecânicas de compósitos LVL produzidos com a madeira de paricá (Schizolobium amazonicum Huber ex. Ducke), por meio de Stress Wave Timer. Os compósitos foram confeccionados em laboratório, dos quais foram retiradas amostras, que foram inicialmente destinadas à realização dos ensaios não destrutivos. Todas as amostras, com dimensões de 2,2 × 2,2 × 40 cm, foram ensaiadas, não destrutivamente, com a propagação de ondas nos sentidos flatwise e edgewise. Em sequência, as mesmas amostras foram destinadas à confecção de subamostras, para realização dos ensaios destrutivos, físicos (absorção de água, inchamento em espessura e inchamento residual) e mecânicos (resistência e rigidez à flexão estática flatwise; resistência e rigidez à flexão estática edgewise; resistência à compressão paralela e resistência ao cisalhamento paralelo e perpendicular). A velocidade de propagação das ondas (V0) e o módulo de elasticidade dinâmico (Emd), obtidos com o auxílio do Stress Wave, foram utilizados para elaboração de modelos de predição das propriedades avaliadas. Os resultados indicaram que o Stress Wave Timer apresenta resultados satisfatórios para predição das propriedades mecânicas de compósitos LVL. Com relação às propriedades físicas, embora tenham sido verificados modelos com ajustes significativos, constatou-se limitação dessa ferramenta para predição desses parâmetros. Contudo, considerando ambas as propriedades, físicas e mecânicas, os melhores ajustes foram observados em amostras ensaiadas com a propagação de ondas no sentido edgewise e com o uso da variável independente Emd.
Resumo:
This study aimed to evaluate the effect of horizontal plate meter with oblong holes operating with one or two seed outlets at different speeds over the accuracy of longitudinal distribution of common bean seeds (Phaseolus vulgaris L.). The experiment was performed in laboratory using the meter with one and two seed outlet points in relation to ten tangential disk plate speeds (0.03 to 0.30 m s-1). It was used a complete randomized design with four replications, summing up 80 experimental treatments. Tangential speed quantitative factor was estimated through a 2nd order polynomial regression. There was no significant difference in the behavior of the seed meter operating with one or two outlets in the metering of bean seeds in all tested speeds, with percentage of single seeds spacing over 60% in tangential speeds below of 0.24 m s-1.
Resumo:
ABSTRACT Global warming increases the occurrence of events such as extreme heat waves. Research on thermal and air conditions affecting broiler-rearing environment are important to evaluate the animal welfare under extreme heat aiming mitigation measures. This study aimed at evaluating the effect of a simulated heat wave, in a climatic chamber, on the thermal and air environment of 42-day-old broilers. One hundred and sixty broilers were housed and reared for 42 days in a climatic chamber; the animals were divided into eight pens. Heat wave simulation was performed on the 42nd day, the period of great impact and data sampling. The analyzed variables were room and litter temperatures, relative humidity, concentrations of oxygen, carbon monoxide and ammonia at each pen. These variables were assessed each two hours, starting at 8 am, simulating a day heating up to 4 pm, when it is reached the maximum temperature. By the results, we concluded that increasing room temperatures promoted a proportional raise in litter temperatures, contributing to ammonia volatilization. In addition, oxygen concentrations decreased with increasing temperatures; and the carbon monoxide was only observed at temperatures above 27.0 °C, relative humidity higher than 88.4% and litter temperatures superior to 30.3 °C.