28 resultados para Thickness measurement.

em Scielo Saúde Pública - SP


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the present study was to measure full epidermal thickness, stratum corneum thickness, rete length, dermal papilla widening and suprapapillary epidermal thickness in psoriasis patients using a light microscope and computer-supported image analysis. The data obtained were analyzed in terms of patient age, type of psoriasis, total body surface area involvement, scalp and nail involvement, duration of psoriasis, and family history of the disease. The study was conducted on 64 patients and 57 controls whose skin biopsies were examined by light microscopy. The acquired microscopic images were transferred to a computer and measurements were made using image analysis. The skin biopsies, taken from different body areas, were examined for different parameters such as epidermal, corneal and suprapapillary epidermal thickness. The most prominent increase in thickness was detected in the palmar region. Corneal thickness was more pronounced in patients with scalp involvement than in patients without scalp involvement (t = -2.651, P = 0.008). The most prominent increase in rete length was observed in the knees (median: 491 µm, t = 10.117, P = 0.000). The difference in rete length between patients with a positive and a negative family history was significant (t = -3.334, P = 0.03), being 27% greater in psoriasis patients without a family history. The differences in dermal papilla distances among patients were very small. We conclude that microscope-supported thickness measurements provide objective results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonic attenuation coefficient, wave propagation speed and integrated backscatter coefficient (IBC) of human coronary arteries were measured in vitro over the -6 dB frequency bandwidth (36 to 67 MHz) of a focused ultrasound transducer (50 MHz, focal distance 5.7 mm, f/number 1.7). Corrections were made for diffraction effects. Normal and diseased coronary artery sub-samples (N = 38) were obtained from 10 individuals at autopsy. The measured mean ± SD of the wave speed (average over the entire vessel wall thickness) was 1581.04 ± 53.88 m/s. At 50 MHz, the average attenuation coefficient was 4.99 ± 1.33 dB/mm with a frequency dependence term of 1.55 ± 0.18 determined over the 36- to 67-MHz frequency range. The IBC values were: 17.42 ± 13.02 (sr.m)-1 for thickened intima, 11.35 ± 6.54 (sr.m)-1 for fibrotic intima, 39.93 ± 50.95 (sr.m)-1 for plaque, 4.26 ± 2.34 (sr.m)-1 for foam cells, 5.12 ± 5.85 (sr.m)-1 for media and 21.26 ± 31.77 (sr.m)-1 for adventitia layers. The IBC results indicate the possibility for ultrasound characterization of human coronary artery wall tissue layer, including the situations of diseased arteries with the presence of thickened intima, fibrotic intima and plaque. The mean IBC normalized with respect to the mean IBC of the media layer seems promising for use as a parameter to differentiate a plaque or a thickened intima from a fibrotic intima.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our objective was to study the effect of dorzolamide on corneal hydration in an 18-week controlled experiment using ultrasonic pachymetry. Twenty-eight male rabbits were divided randomly into four groups. The 7 rabbits in each group received eye drops containing either 2% (w/v) dorzolamide or placebo in their right eye, or in their left eye. The 2% dorzolamide rabbits were treated every 8 h. Fellow eyes are defined as eyes which did not receive either dorzolamide or placebo. The study was blind for both the person who applied the drug and the one who performed the pachymetry. The effect of treatments is reported on the basis of the percentage of pachymetric variation compared to the measurement made before drug application. There was no significant difference (P = 0.061) in pachymetric variation between dorzolamide (-4.42 ± 11.71%) and placebo (2.48 ± 9.63%). However, there was a significant difference (P = 0.0034) in pachymetric variation between the dorzolamide fellow eyes (-7.56 ± 10.50%) and the placebo (-4.42 ± 11.71%). In conclusion, dorzolamide did not increase the corneal thickness in rabbits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To measure the thickness of adductor pollicis muscle in healthy adults. This measurement will be used as a nutritional anthropometric parameter in further studies. SUBJECTS AND METHOD: Four hundred and twenty-one healthy adults were studied, 209 men and 212 women, with ages ranging from 18 to 87 years, living in Rio de Janeiro. The adductor pollicis muscle was also studied in the human anatomy lab as well as in normal healthy volunteers using CAT scans and nuclear magnetic resonance imaging to ensure that only the adductor pollicis was included in measurement of muscle thickness with a Lange caliper. To standardize the measurement, the methodology was detailed, with subjects sitting with the dominant hand dangling over the homolateral thigh and the elbow bent at approximately a 90° angle. The Lange caliper was applied at a pressure of 10 g/mm², pinching the adductor pollicis muscle at the vertex of an imaginary angle between the thumb and the index finger. The average of 3 consecutive measurements was considered to be the muscle thickness. RESULTS: This study provides the first estimates of adductor pollicis thickness in normal healthy subjects as an anthropometric parameter. The normal values in the dominant hand for men were 12.5 ± 2.8 mm (mean ± SD), median 12 mm, and for women were 10.5 ± 2.3 mm, median 10 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.