93 resultados para Testes de espectrofotometria de UV-Vis
em Scielo Saúde Pública - SP
Desenvolvimento de método analítico para quantificação do efavirenz por espectrofotometria no UV-Vis
Resumo:
An UV-Vis spectrophotometry analytical method for quantifying Efavirenz was developed and validated as an alternative to replace the HPLC current method. The report method presents sample concentration of 10 μg mL-1, dissolved in a solution ethanol:water (60:40, v/v), economic and technically adequate for the purpose adopted. The results and the statistical treated proved that the method being considered an precise and accurate analytical low cost alternative for laboratory routine. The adaptability of this method in product and other analytical methods development has been challenged by mathematical calculation of drug extinction coefficient in water and methanol and practical experiments, showing interesting results.
Resumo:
This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.
Resumo:
Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.
Resumo:
Os corantes sintéticos são usualmente adicionados a alimentos industrializados para conferir e restaurar a cor obtendo-se a qualidade estética desejada. Em função destes aspectos e do potencial toxicológico que alguns corantes podem apresentar, o controle de qualidade destes compostos é de fundamental importância. Neste trabalho, foi estudado o potencial das metodologias matemáticas como o princípio da aditividade, espectrofotometria derivativa e técnica multivariada (Regressão por Mínimos Quadrados Parciais - PLSR) na determinação simultânea de dois corantes alimentícios: Amarelo Crepúsculo (AC) e Amarelo Tartrazina (AT), extraídos com lã natural. Estas metodologias foram avaliadas e comparadas em função das suas capacidades de previsão, sendo que o modelo PLSR otimizado (faixa espectral de 305 a 645 nm, empregando-se 1ª derivada como transformação dos dados e 2 componentes principais) apresentou o menor valor de Raiz Quadrada da Soma dos Erros de Previsão (RMSEP) (AT = 0,191 e AC = 0,102). A faixa de concentração estudada foi de 1,0 a 16,0 mg.L-1 para AC e de 2,0 a 22,0 mg.L-1 para AT. O conjunto de validação externa apresentou erros relativos médios de 1,97% para AC e 1,39% para AT. A aplicação desta metodologia em amostras reais mostrou que em todas as amostras analisadas as concentrações destes corantes estavam de acordo com os limites estabelecidos pela legislação brasileira
Resumo:
Foram caracterizados fisico-quimicamente ácidos húmicos, obtidos de composto de resíduos sólidos urbanos (AH-CRSU) e de lodo de estação de tratamento de esgoto (AH-LETE), ambos produzidos na cidade do Rio de Janeiro, por meio da análise da composição elementar, acidez total, de dados espectroscópicos (UV-Vis; IV, RMN de 13C-CP/MAS) e microscopia eletrônica de varredura (MEV). A análise das características estruturais revelou diferenças entre os AHs estudados. A presença de sistemas aromáticos foi observada por meio da espectroscopia de UV-Vis, indicando sistemas mais substituídos nos AH-LETE. A espectroscopia na região do infravermelho (IV) mostrou a presença de estruturas alifáticas nos AHs e maior complexidade nos sinais de absorção devida a polissacarídeos nos AH-CRSU. Além disso, foram observados grupos OH, COOH, COO-, CO2NH2, e confirmada a presença de sistemas aromáticos. Com a análise de RMN de 13C-CP/MAS, foi possível verificar as diferenças quantitativas nos diferentes tipos de carbono. Os AH-LETE apresentaram maior quantidade de grupos aromáticos e de COOH. A análise de RMN de 13C-CP/MAS também mostrou presença de polissacarídeos, N em aminoácidos e grupamentos OCH3. O conjunto de propriedades avaliadas permitiu indicar que a fração ácidos húmicos dos resíduos é "do tipo" ou "análoga" aos ácidos húmicos de origem pedogênica.
Resumo:
A spectrophotometric method was proposed for Ni(II) determination in alloys using a dopa-semiquinone (L-1) to form [Ni(II)(L1-)3]1-, ε = 9.3 x 10³ L mol-1 cm-1. The optimal conditions for the determination were: wavelength 590 nm, temperature 25 °C, reaction time 45 min and pH 7.5. The Beer's law was obeyed for nickel from 3.33 x 10-5 to 1.78 x 10-4 mol L-1. The method was applied to complex samples, such as inox, nickel-titanium and cobalt-chromium alloys. A study of the potential interferents revealed that Mn was the major interferent. The limit of detection and quantification were 2.88 x 10-5 mol L-1 and 3.06 x 10-5 mol L-1, respectively.
Resumo:
A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from the application of Hierachical Cluster Analysis (HCA) to the matrix of the data involving all samples show the formation of fifteen types of wine. A Soft Independent Modelling of Class Analogy (SIMCA) model was constructed and used to classify the samples of the overall forecast. As a result, it is observed that the prediction was performed with a success rate of 99.2% for a confidence level of 95%. This shows that the proposed methodology can be used as an effective tool for classifying of samples of wines.
Resumo:
The post-preparative size-selective precipitation technique was applied in CdTe and CdSe semiconductor nanocrystals prepared via colloidal route in water. The synthesis of CdTe and CdSe nanoparticles and the effect of the post-preparative size-selective precipitation have been characterized mainly by mean of ultraviolet and visible absorption spectroscopy (UV-Vis). It was demonstrated that the size-selective precipitation are able to isolate particles of different sizes and purify the nanoparticles as well.
Resumo:
Caesalpinia peltophoroides is a domesticated tree found in Brazil. It was necessary to develop an analytical method to determine the content of total polyphenols (TP) in this herbal drug. The pre-analytical method was standardized for analysis time, wavelength, and the best standard to use. The optimum conditions were: pyrogallol, 760 nm, and 30 min respectively. Under these conditions, validation by UV/Vis spectrophotometry proved to be reliable for TP of the crude extract and semipurified fractions from C. peltophoroides. Standardization is required for every herbal drug, and this method proved to be linear, precise, accurate, reproducible, robust, and easy to perform.
Resumo:
A statistical mixture-design technique was used to study the effects of different solvents and their mixtures on the yield, total polyphenol content, and antioxidant capacity of the crude extracts from the bark of Schinus terebinthifolius Raddi (Anacardiaceae). The experimental results and their response-surface models showed that ternary mixtures with equal portions of all the three solvents (water, ethanol and acetone) were better than the binary mixtures in generating crude extracts with the highest yield (22.04 ± 0.48%), total polyphenol content (29.39 ± 0.39%), and antioxidant capacity (6.38 ± 0.21). An analytical method was developed and validated for the determination of total polyphenols in the extracts. Optimal conditions for the various parameters in this analytical method, namely, the time for the chromophoric reaction to stabilize, wavelength of the absorption maxima to be monitored, the reference standard and the concentration of sodium carbonate were determined to be 5 min, 780 nm, pyrogallol, and 14.06% w v-1, respectively. UV-Vis spectrophotometric monitoring of the reaction under these conditions proved the method to be linear, specific, precise, accurate, reproducible, robust, and easy to perform.
Resumo:
A técnica de CLAE com detecção UV-Vis foi empregada na análise do teor de cocaína em amostras apreendidas de cocaína e crack. Uma fase móvel de acetonitrila/água (95:5v/v) possibilitou um sinal de pico para a cocaína em 3,5 minutos. O sinal espectrofotométrico otimizado foi obtido em um comprimento de onda de 224 nm. A curva analítica de 1,0 a 40,0 ppm para cocaína foi obtida, exibindo um coeficiente de correlação linear de 0,9989, com limites de detecção e quantificação de 0,75 e 3,78 ppm, respectivamente. Esta metodologia foi aplicada na dosagem de amostras confiscadas de cocaína e crack no Laboratório de Polícia Científica de Ribeirão Preto-SP.
Resumo:
A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.
Resumo:
Dentre as ferramentas usadas para descrever a estrutura ramificada ou a superfície rugosa e distorcida de ácidos húmicos (AH), a geometria fractal aparece como uma das mais adequadas para explicar a conformação de partículas húmicas (agregados moleculares). Do ponto de vista experimental, a dimensão fractal (D) de sistemas naturais pode ser determinada a partir do monitoramento da luz transmitida, não espalhada e não absorvida (turbidimetria 'τ'). A presença de fractais implica que o sistema pode ser decomposto em partes, em que cada uma, subseqüentemente, é cópia do todo. A determinação do valor 'D' dessas partículas foi conseguida pela utilização de turbidimetria, em que suspensões de AH-comercial e de AH-Espodossolo foram analisadas por espectrofotometria UV-Vis. O fundamento matemático utilizado foi a lei de potência τ ∝ λβ, em que β < 3 indica a presença de fractal de massa (Dm); 3 < β < 4 indica fractal de superfície (Ds), e β ≅ 3 indica não-fractal (NF). A declividade das retas (β) por meio do gráfico (logτ vs logλ) permitiu a obtenção de 'D'. Segundo os resultados, partículas de AH em suspensões aquosas diluídas formam estruturas fractais, cuja geometria pode ser caracterizada por meio de turbidimetria. Entretanto, a faixa de comprimento de onda usada (400 a 550 nm) ainda é pequena para se afirmar sobre a natureza fractal de AH e determinar suas dimensões fractais com precisão.
Resumo:
Foram comparadas as concentrações de Na, K e P em extratos de solos, obtidas por um método de extração convencional, no qual é utilizada uma razão solo:extrator (Mehlich-1) de 1:10, com aquelas encontradas utilizando uma razão solo:extrator (Mehlich-1) de 1:5. Também, foram comparados os resultados obtidos por técnicas de quantificação convencionais, nas quais Na e K são quantificados por fotometria de chama e P por espectrofotometria de absorção molecular, com aqueles encontrados por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Foram analisadas 15 amostras de solo brasileiro. No estudo de repetibilidade aplicado a todos os resultados, os maiores CVs foram encontrados para P e Na, principalmente quando as concentrações dos analitos foram menores (< 9 mg dm-3 para P e < 10 mg dm-3 para Na). Esse fato foi devido provavelmente à heterogeneidade dos extratos, que continham partículas coloidais. Filtração ou centrifugação em vez de decantação dos extratos provavelmente resultaria em menores CVs. No estudo de reprodutibilidade, realizado para três amostras, foram obtidos resultados não reprodutíveis somente para K em uma amostra. Todos os resultados obtidos por ICP OES foram semelhantes aos obtidos por espectrofotometria de absorção molecular UV-Vis. e fotometria de chama, indicando que a primeira técnica foi adequada para determinação de Na, K e P nos extratos de solos tropicais obtidos com solução de Mehlich-1. Os resultados de Na, K e P obtidos com razão solo:extrator de 1:5 foram estatisticamente diferentes daqueles em que se utilizou razão solo:extrator de 1:10. A maioria dos resultados obtidos com razão solo:extrator de 1:5 foi menor que os obtidos com razão solo:extrator 1:10, sobretudo nas amostras com concentrações de analitos mais elevadas. Portanto, para estudos comparativos envolvendo macronutrientes, deve-se utilizar o método convencional com razão solo:extrator de 1:10.