21 resultados para Shake-flask

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most preferred containers by Aedes aegypti were studied April and July (rainy and dry periods) in two Manaus neighbourhoods. In all, 2,700 premises and 13,912 containers were examined, most (87%) recorded outdoors. Out of the 13,100 inspected premises, only 1.6% showed to be positive for Aedes aegypti, summing up to 7,916 collected samples. Most frequently found containers outdoors in either neighbourhood regardless of rain or dry period were Bottles flasks and Storage, and indoors, Fixed, Flowerpots, and buckets. Productivity was estimated according to the number of premises and positive containers investigated, showing the actual container groups productivity. Considering both rainy and dry periods outdoors at Praça 14 the groups of Tyre, Flask, Bottle, Construction Equipment and Fixed, had the highest averages respectively. Construction Equipment and Flask groups were the most productive in Coroado in April. Flask, Construction Equipment and Storage groups stood out in July.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The photometric determination of ascorbic acid with the "E. E. L. portable colorimeter" can be carried" out rapid and conveniently using either 3% HPO3 or 0,4% (COOH) 2 as protective agent. The standards would contain from 2 to 20 micrograms of ascorbic acid per ml of metaphosphoric or oxalic acid solutions. We mix 10 ml of these solutions with 3 ml of the adequate citrate buffer solutions, and we pipet 5 ml of the resulting mixture to a matched test tube containing 5 ml of sodium - 2,6 - dichlorobenzenoneindophenol (80 mg per liter); then we shake well and after 15 seconds the extintion is read using green filter. The readings are subtracted from the blank one. Designating the differences by x and the concentrations of ascorbic acid/ml in the standards by y, we get, with the acid of the method of least squares, the following regression equations: for the metaphosphoric acid Y = 0,543x + 0,629 for the oxalic acid Y = 0,516x + 0,422, which permit, by interpolating, the determination of the ascorbic acid content in plant materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phosphate "fixation" is the convertion of soluble into insoluble phosphate in the soil. There are many factors conditioning phosphate fixation by soil such as reactions originating less soluble compounds (phosphates of iron, aluminum, calcium, magnesium, etc.), PO4-3 adsorption by the colloidal fraction of soils, PO4-3 absorption by the soil microflora, etc. Certain soils of the state of São Paulo (Brazil) are relatively rich in both iron and aluminum oxides. PO4-3 fixation, using P31 and P32 has been verified by researchers, specially with "Terra Roxa". The known methods for fixation evaluation are conventional as this depends on phosphate solution concentration, pH, time of contact between soil and solution, relation of sample weight to solution volume, shaking time, etc. In this experiment, the following conventional method was used: 4 g of soil were shaken for 15 minutes at 30-40 rpm, in 300 ml Erlenmeyer flask in a Wagner shaking machine, together with 100 ml of 0,03 normal phosphate solution (being 0,01 normal as PO4-3 contributed by H8PO4 and 0,02 normal as PO4-3 from KH2PO4). After shaking it was set aside for 24 hours and then filtered. Phosphate was determined in a suitable aliquot of both the original solution (blank) and the soil extract, by the vanadomolibidic-phosphoric acid method. From phosphate concentration in the blank minus phosphate concentration in the soil stract the rate of fixation by 100 g of soil was calculated. The data obtained show that "Terra Roxa" and "Terra Roxa Misturada" have a fairly high PO4-3 fixation capacity, varying from 10 to 24 milliequivalents of PO4-3 per 100 g of soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with a modification in the solubilization technique of natural phophates in the 2% citric acid solution. The proposed technique is as follows: 2,5 g of phosphatic material and 250 ml of 2% citric acid solution, in a 500 ml Erlenmeyer flask, are shaken for 30 minutes at 30-40 rpm. The phosphorus (P2O5) was determined by the usual method. The data obtained were compared with the conventional technique in which a Stohmann bottle is used. The natural phosphates used were: Phosphorita de Olinda (Pernambuco), Flórida Phosphate (USA) and Hiperphosphate (África). Statistical analysis was applied to the data and the following conclusions were arrived at: a) The precision is equivalent in both techniques. b) There is no significant variation between the means obtained with the two technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A critical study of three methods for the determination of lactic acid (EDWARDS, MENDEL & GOLDSCHEIDER, MILLER & MUNTZ) is presented and some modifications are proposed. It was shown t hat more accurate results could be obtained with Edward's technic when an Iena glass filter is connected with the absorption tube. Before the dropping of the permanganate solution it is necessary to pass a current of air through the reaction flask to avoid the oxidation of the non-lactic acid substances which interfere with the reaction. The absorption tube must be maintained at 18°C during the destillation and the titration of the bisulphite binding aldehyde at 4°C. When the sample contains more than 5 mg it is useful to work with greater quantities of the bisulphite. More permanganate is consumed when the lactic acid concentration is higher. The sensivity of the method permits the titration of 0.04 mg to 5 mg of lactic acid in the sample. The calculated error of the method gave 0.018 % and the normal values for blood determined in 20 human cases averaged 10.30 mg per 100 ml (Table VI). MENDEL and GOLDSCHEIDER'S method was modified in the following details: Somogyis deproteinization was performed instead metaphosphoric acid as in the original method; to avoid the evaporation of the acetic aldehyde during the heating time with sulfuric acid a special glass stopped tube is proposed (Fig. 2). The reaction with sulfuric acid and veratrol is performed in an ice bath. Blood proteins precipitants were tried and Somogyi's lattest tecnic showed better results (Table V). Colorimetric readings were done in the PULFRICH photometer using filter S 53 and a 10 mm cup. The method is accurate within an error of 0.23 % and samples of 5 to 70 microg. could be easily determined. Normal values for human blood averaged 10.78 mg per 100 ml. More accurate results were obtained with the technic of MILLER & MUNTZ. Slight modifications were introduced: deproteinization with copper sulfate and sodium tungstate; satured p-hydroxydiphenyl solution according to KOENEMANN which is stable for 5 months when stored in the ice-box. Using the PULFRICH step-photometer the error is 0.17% with samples varying from 0.1 to 10 microg. of lactic acid. The filter employed was S 57 with the 5 mm cup. The method was adapted to 0.1 ml of blood. Normal values for human blood gave an average of 10.58 mg per 100 ml.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A technics for prefreezing of blood plasma and serum is described in this paper. The method indicated by Strumia et al. (2), uses a rapid local freezing to obtain the shell-freezing, with refigerated alcohol bath, at temperatures around minus 35ºC. On our work, it has been found that normal horse blood plasma fulfils the instructions given by Strumia, although normal human blood plasma, very often, fails to give the expected results. This is very disadvantageous at the routine work. With the use of small amounts of solid carbon dioxide, spread over the flasks, in the refrigerated bath, it has been possible to start the chrystallization. The technics prescribes a rapid cooling, like the one used by Strumia, to bring the temperature down, to about plus 10ºC. and, with rotating device stopped, the solid carbon dioxide is applied for one minute simultaneously on each flask. Starting rotation again, it begins to form a very uniform shell around the walls of the flasks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mauritia vinifera (buriti) is a palm tree that grows wild in different areas of Brazil, particularly in the Amazonian region. The buriti oil is rich in carotenoids, especially in β-carotene. The growing interest in other natural sources of β-carotene has stimulated the industrial use of buriti as a raw material for pulp oil extraction. Most processes are based on the conventional technologies, involving drying and pressing the pulp for oil recovery and further separation of carotenoids in a liquid phase using organics solvents. In the present work, the ethanol-based process was evaluated for simultaneous carotenoids recovering and fractionating from buriti pulp. The raw material and ethanol, 1:4 ratio, were placed in an erlenmeyer flask and maintained at 30rpm for 1 hour in a temperature-controlled bath at 65ºC. The mixture was filtered under vacuum and cooling at 10ºC to allow for the separation of the solvent in two phases. Carotenoids composition, determined by HPLC, has indicated a β-carotene concentration about 12 times greater in the lower phase than in the upper phase. The profile of the carotenoids in the denser phase is quite similar to that of raw buriti oil, and the concentration of total carotenoids is 40% higher than that of the original raw oil, making the ethanol-based process particularly attractive for industrial applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractObjective:To evaluate by magnetic resonance imaging changes in bone marrow of patients undergoing treatment for type I Gaucher’s disease.Materials and Methods:Descriptive, cross-sectional study of Gaucher’s disease patients submitted to 3 T magnetic resonance imaging of femurs and lumbar spine. The images were blindly reviewed and the findings were classified according to the semiquantitative bone marrow burden (BMB) scoring system.Results:All of the seven evaluated patients (three men and four women) presented signs of bone marrow infiltration. Osteonecrosis of the femoral head was found in three patients, Erlenmeyer flask deformity in five, and no patient had vertebral body collapse. The mean BMB score was 11, ranging from 9 to 14.Conclusion:Magnetic resonance imaging is currently the method of choice for assessing bone involvement in Gaucher’s disease in adults due to its high sensitivity to detect both focal and diffuse bone marrow changes, and the BMB score is a simplified method for semiquantitative analysis, without depending on advanced sequences or sophisticated hardware, allowing for the classification of the disease extent and assisting in the treatment monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Angle-resolved electron energy-loss spectra have been measured for the methyl methacrylate (MMA) and styrene molecules in the 0 - 50 eV energy range. The spectra have been obtained at 1 keV incident energy, with an energy resolution of 0.8 eV and covering an angular range of 2.0 to 7.0 degrees. Within our knowledge, this is the first gas-phase excitation spectrum for MMA and styrene in this energy range. The spectra of MMA at small scattering angles are dominated by an intense peak at 6.7 eV followed by a broad band centered at about 16 eV. In the case of styrene, six bands can be observed in the spectra. Based on the angular behaviour of the excitation spectra of these molecules, the low-lying peaks observed are considered to be associated predominantly with dipole-allowed processes. In both cases, new bands can be observed for excitation energies greater than 20 eV. This could be associated with dipole-forbidden transitions to shake-up and doubly-excited states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the selective reduction procedure proposed by Magos SnCl2 was used as reductant for inorganic mercury while total mercury was determined after reduction with a mixture of SnCl2 and CdCl2. The difference between total mercury and inorganic mercury determines the content of organic mercury. The procedure of the present work differs of Magos in that the mercury vapour is carried to the absorption cell after magnetic stirring of the solution in the reaction flask; in the Magos procedure, mercury vapour is carried by bubbling the gas in to the solution. In contrast to the Magos procedure this slight modification overcame the necessity of at calibration by analyte addition, saving time and gainning accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquarium air pumps are proposed and evaluated as pneumatic liquid propulsion devices for flow injection and continuos flow analysis (FIA and CFA) systems. This kind of pump is widely available at a very low cost and it can sustain a pressure around of 4 psi (0.28 bar) indefinitely. By applying this air pressure onto a solution contained in a reservoir flask, it is possible to reach flow rates of up to 12.5 mL min-1 for circuits comprising reactors, made from 0.8 i.d. tubing with a length of 100 cm. The precise adjustment of flow rate below the maximum one can be made with a simplified needle valve or inserting in series a short length of capillary tube. The absence of flow pulsation is a definite advantage in comparison with peristaltic pumps, especially when amperometric detection is elected, as confirmed experimentally in FIA and CF applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to study the oxidation of a complex molybdenite mineral which contains pyrite and pyrrotite, by Acidithiobacillus ferrooxidans. This study was performed by respirometric essays and bioleaching in shake flasks. Respirometric essays yielded the kinetics of mineral oxidation. The findings showed that sulfide oxidation followed classical Michaelis-Menten kinetics. Bioleaching in shake flasks allowed evaluation of chemical and mineralogical changes resulting from sulfide oxidation. The results demonstrated that pyrrotite and pyrite were completely oxidized in A. ferrooxidans cultures whereas molybdenite was not consumed. These data indicated that molybdenite was the most recalcitrant sulfide in the sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vitamin C degradation was evaluated in industrialized cashew juice of high pulp content and in cajuina by the method of Tillmans during eleven days of storage after the opening of the flask. For recently opened juices, vitamin C was found in the concentration range of 112 to 170 mg for 100 g of juice. The degradation of vitamin C in industrialized cashew juices changes when different additives are used. All of the cajuinas presented a vitamin C content below that specified on the label.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the production of polyhydroxyalkanoates (PHAs) by fermentation of Crude Glycerin, a byproduct of the biodiesel industry, by Cupriavidus necator IPT 026, 027 and 028. The influence of fermentation time and temperature in shake flasks were evaluated. The highest PHA production (2.82 g L-1) occurred at 35 ºC for 72 h of fermentation. The melting and initial thermal degradation temperatures of this PHA were 177.9 ºC and 306.33 ºC, respectively, with 55% crystallinity. FTIR spectrum was similar to those reported in literature. The polymer obtained presented three different methyl esters of hydroxyalkanoates in its composition, with molecular weight of 630 kDa. Bacteria can use Crude Glycerin as an inexpensive substrate to produce value-added biodegradable products, such as PHA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.