38 resultados para Potentiometric titration

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT Intrinsic equilibrium constants of 17 representative Brazilian Oxisols were estimated from potentiometric titration measuring the adsorption of H+ and OH− on amphoteric surfaces in suspensions of varying ionic strength. Equilibrium constants were fitted to two surface complexation models: diffuse layer and constant capacitance. The former was fitted by calculating total site concentration from curve fitting estimates and pH-extrapolation of the intrinsic equilibrium constants to the PZNPC (hand calculation), considering one and two reactive sites, and by the FITEQL software. The latter was fitted only by FITEQL, with one reactive site. Soil chemical and physical properties were correlated to the intrinsic equilibrium constants. Both surface complexation models satisfactorily fit our experimental data, but for results at low ionic strength, optimization did not converge in FITEQL. Data were incorporated in Visual MINTEQ and they provide a modeling system that can predict protonation-dissociation reactions in the soil surface under changing environmental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A direct potentiometric titration method was applied to commercial and soil humic acids in order to determine their carboxyl and phenol group concentrations and apparent and intrinsic pK. In that context, acid-base properties of humic acids are interpreted by selective blocking of carboxylic and phenolic groups by esterification and acetylation. Differences in underivatized and derivatized HA's acid-base properties are ascribed to carboxyl and phenol groups influence on total humic acidity. Potentiometric data were treated with the modified Henderson-Hasselbalch equation. Infra red results, the acidic group contents and the average values of apparent and intrinsic pK for underivatized and derivatized HAs confirmed the selectivity of esterification derivatization method. After blocking of the functional groups, the values of acidic group contents decreased, while the value of apparent pK increased after derivatization. Phenol groups cannot be specifically identified by the acetylation method, due to low selectivity of the acetylation method.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A potentiometric Nickel sensor was prepared using 2-hydroxy-1-naphthylidene-N-cyanoacetohydrazone as electro-active material and epoxy resin as a binding material. A membrane composed of 40% Schiff's base and 60% epoxy resin exhibited the best performance. The membrane showed excellent response in the concentration range of 0.15 ppm to 0.1 mol L- 1 Ni+2 ions with non-Nernstian slope of 22.0 mV/decade, had a rapid response time (less than 10 s), and can be used for three months without any considerable loss of potential. The sensor was useful within the pH range of 1.3 to 9.6, and was able to discriminate between Ni2+ and a large number of alkaline earth and transition metal ions. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Ni2+ with EDTA and oxalic acid.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The combination of two low-cost classical procedures based on titrimetric techniques is presented for the determination of pyridoxine hydrochloride in pharmaceuticals samples. Initially some experiments were carried out aiming to determine both pKa1 and pKa2 values, being those compared to values of literature and theoretical procedures. Commercial samples containing pyridoxine hydrochloride were electrochemically analysed by exploiting their acid-base and precipitation reactions. Potentiometric titrations accomplished the reaction between the ionizable hydrogens present in pyridoxine hydrochloride, being NaOH used as titrant; while the conductimetric method was based on the chemical precipitation between the chloride of pyridoxine hydrochloride molecule and Ag+ ions from de silver nitrate, changing the conductivity of the solution. Both methods were applied to the same commercial samples leading to concordant results when compared by statistical tests (95 and 98% confidence levels). Recoveries ranging from 99.0 to 108.1% were observed, showing no significant interference on the results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acid base properties of mixed species of the microalgae Spirulina were studied by potentiometric titration in medium of 0.01 and 0.10 mols L-1 NaNO3 at 25.0±0.10 C using modified Gran functions or nonlinear regression techniques for data fitting. The discrete site distribution model was used, permitting the characterization of five classes of ionizable sites in both ionic media. This fact suggests that the chemical heterogeneity of the ionizable sites on the cell surface plays a major role on the acid-base properties of the suspension in comparison to electrostatic effects due to charge-charge interactions. The total of ionizable sites were 1.75±0.10 and 1.86±0.20 mmolsg-1 in ionic media of 0.01 and 0.10 mols L-1 NaNO3, respectively. A major contribution of carboxylic groups was observed with an average 34 and 22% of ionizable sites being titrated with conditional pcKa of 4.0 and 5.4, respectively. The remaining 44% of ionizable sites were divided in three classes with averaged conditional pcKa of 6.9, 8.7 and 10.12, which may be assigned respectively to imidazolic, aminic, and phenolic functionalities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The data analyzed in this work were generated following the methodology developed by Molina et al.(J. Electroanal. Chem., 1979) for the calibration of a potentiometric system of measurement of hydrogen-ion concentrations resulting from neutralizations, at 25 ºC, of acidic or alkaline solutions at constant ionic strength (0.1 mol.l-1) held with NaClO4. The observed data present a serious deviation in relation to the mathematical model derived from the Nernst equation, for pH values ranging from 3 to 11, where pH=-log[H+]. We show that the minimization of the sum of the absolute values of the residuals gives estimates that are not influenced by outlying values.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Free fatty acids are a measure of evaluating fats and oils, submitted to abusive conditions, besides being a quality characteristic of edible vegetable oils. The official method of determination (AOCS Ca 5a-40, 2004) is based on titration, using phenolphthalein as an indicator. For crude and degummed oils, the titration end point is difficult to be observed due to the high level of pigments, resulting in dark solutions. In this case and others, such as self-life studies, in which sample quantities are limited, potentiometric titration may be a very good alternative.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Proton binding properties of humic and fulvic acids were studied by potentiometric titration. Carboxylic groups were the predominant ionizable sites in comparison to phenolic and amine groups. Total acidity of fulvic acid was 12 x 10-3 mol g-1, a number significantly higher than that obtained for humic acid (5.2 x 10-3 mol g-1). Copper ion binding was evaluated at pH 4, 5 and 6 by potentiometric titration with an ion selective electrode for Cu(II). Differential stability constants and complexation capacities were systematically higher for humic acid, despite its lower number of ionizable sites in comparison with fulvic acid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This works proposes a homemade construction of a lead(II) ISE of solid membrane (Ag2S/PbS) to determine Pb2+ ions in potentiometric titrations, using damaged combined glass electrodes. This electrode can be constructed in teaching laboratories, using it as a learning tool related to the theoretical principle of ISE. The analytical curve obtained (y = 27.056x + 337.58; R = 0.996) was linear on the range of 1 x 10-5 to 1 mol L-1 and has presented a very close behavior of the Nernstian. The homemade ISE has presented a similar selectivity to the commercial electrodes, showing to be a good alternative to the experimental activities on teaching laboratories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

TitDrop II, a practice low-cost titrator based on drop counting is proposed. A microcomputer counts drops in an opto-switch and it receives pH values from a commercial pHmeter with RS-232 serial port. The volume of drops must kept constant and the amount of base in each drop is obtained by standardization in the titrator. A linear behavior between height of reservoir of titrant and drop frequency was observed, but there is no influence of low height on drop volume. Acetic acidity in samples of vinager was compared with volumetric titration, and deviation between -2.6 to 3.9% was observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the creation of an very simple calculation algorithm, based in basic chemical and mathematic principles, for the calculation of weak diprotic acid dissociation constants as, for example, amino acids, from potentiometric titrations. For an easier understanding of the algorithm the logical reasoning of this calculus is schematized in a diagram of blocks. In the second part of the work the algorithm is applied to an Excel calculation sheet to determine the dissociation constants of Nicotinic Acid and Glycine, from the respective potentiometric titration curves. The values obtained using this algorithm are compared with those estimated by Hyperquad2008 (program generally used for this type of calculus) and also with the values of a stability constants database.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the determination of the dissociation constant (Ka) of captopril and nimesulide as contextualized experiments to teach chemical concepts to students of Pharmacy. Captopril is an antihypertensive drug, which presents high water-solubility and weak acid properties. The pKa of carboxylic acid group of captopril is 3.7. Nimesulide is a non-steroidal anti-inflammatory drug sparingly soluble in water. It is weakly acidic (pKa ≈ 6.5) because of its methanesulfonamide functional group. The pKa of captopril was determined by potentiometric titration with NaOH 2.0 x 10-2 moL L ¹. The pKa of nimesulide was determined by using spectrophotometry and photometric titration. The experimental values of pKa of both drugs are in very good agreement with those from literature

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work was to synthesize nanosilicas with different degree of hydrophobicity by the sol-gel method, using tetraethyl orthosilicate as a precursor. For this purpose, 3-aminopropyl triethoxysilane (APS) and 1,1,1,3,3,3 - hexamethyldisilazane (HMDS), were added during synthesis as modifiers. A commercial biopolymer (Hexamoll Dinch, BASF) intended for packaging of apples, was added to the new nanosilicas. The materials obtained were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, potentiometric titration, porosity, specific surface area and hydrophobicity/hydrophilicity by wetting test. Colorimetry was used to evaluate change in apple pulp color after contact with the different silicas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.