31 resultados para Plasma and Beam Physics

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We determined the relationship between plasma and red blood cell concentrations of quinine in children with uncomplicated falciparum malaria from an endemic area of Amazonian region. Quinine was determined by high performance liquid chromatography with ultraviolet detection. In the steady state the ratio between plasma and red blood cell quinine concentration was 1.89 ± 1.25 ranging from 1.05 to 2.34. This result demonstrated that quinine do not concentrate in red blood cell of Brazilian children and characterize the absence of interracial difference in this relationship.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was designed to investigate the impact of anti-retroviral therapy on both plasma and seminal HIV-1 viral loads and the correlation between viral loads in these compartments after treatment. Viral load, CD4+ and CD8+ T-cell counts were evaluated in paired plasma and semen samples from 36 antiretroviral therapy-naïve patients at baseline and on days 45, 90, and 180 of treatment. Slopes for blood and seminal viral loads in all treated patients were similar (p = 0.21). Median HIV-1 RNA titers in plasma and semen at baseline were 4.95 log10 and 4.48 log10 copies/ml, respectively. After 180 days of therapy, the median viral load declined to 3.15 log10 copies/ml (plasma) and 3.2 log10 copies/ml (semen). At this timepoint 22 patients presented HIV-1 viral load below 400 copies/ml in either plasma or semen, but only 9 had viral loads below 400 copies/ml in both compartments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE), paracetamol (PAR) and loratadine (LOR) in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition of methanol-0.1% formic acid at a flow rate of 1.0 mL min-1. Mass spectral transitions were recorded in SRM mode. System validation was evaluated for precision, specificity and linearity. Limit of detection for pseudoephedrine, paracetamol, and loratadine were determined to be 3.14, 1.86 and 1.44 ng mL-1, respectively, allowing easy determination in plasma with % recovery of 93.12 to 101.56%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We determined whether ANP (atrial natriuretic peptide) concentrations, measured by radioimmunoassay, in the ANPergic cerebral regions involved in regulation of sodium intake and excretion and pituitary gland correlated with differences in sodium preference among 40 Wistar male rats (180-220 g). Sodium preference was measured as mean spontaneous ingestion of 1.5% NaCl solution during a test period of 12 days. The relevant tissues included the olfactory bulb (OB), the posterior and anterior lobes of the pituitary gland (PP and AP, respectively), the median eminence (ME), the medial basal hypothalamus (MBH), and the region anteroventral to the third ventricle (AV3V). We also measured ANP content in the right (RA) and left atrium (LA) and plasma. The concentrations of ANP in the OB and the AP were correlated with sodium ingestion during the preceding 24 h, since an increase of ANP in these structures was associated with a reduced ingestion and vice-versa (OB: r = -0.3649, P<0.05; AP: r = -0.3291, P<0.05). Moreover, the AP exhibited a correlation between ANP concentration and mean NaCl intake (r = -0.4165, P<0.05), but this was not the case for the OB (r = 0.2422). This suggests that differences in sodium preference among individual male rats can be related to variations of AP ANP level. Earlier studies indicated that the OB is involved in the control of NaCl ingestion. Our data suggest that the OB ANP level may play a role mainly in day-to-day variations of sodium ingestion in the individual rat

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was designed to evaluate the effect of different conditions of collection, transport and storage on the quality of blood samples from normal individuals in terms of the activity of the enzymes ß-glucuronidase, total hexosaminidase, hexosaminidase A, arylsulfatase A and ß-galactosidase. The enzyme activities were not affected by the different materials used for collection (plastic syringes or vacuum glass tubes). In the evaluation of different heparin concentrations (10% heparin, 5% heparin, and heparinized syringe) in the syringes, it was observed that higher doses resulted in an increase of at least 1-fold in the activities of ß-galactosidase, total hexosaminidase and hexosaminidase A in leukocytes, and ß-glucuronidase in plasma. When the effects of time and means of transportation were studied, samples that had been kept at room temperature showed higher deterioration with time (72 and 96 h) before processing, and in this case it was impossible to isolate leukocytes from most samples. Comparison of heparin and acid citrate-dextrose (ACD) as anticoagulants revealed that ß-glucuronidase and hexosaminidase activities in plasma reached levels near the lower normal limits when ACD was used. In conclusion, we observed that heparin should be used as the preferable anticoagulant when measuring these lysosomal enzyme activities, and we recommend that, when transport time is more than 24 h, samples should be shipped by air in a styrofoam box containing wet ice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plasma and tissue testosterone concentrations were determined by radioimmunoassay in 12 eight-month-old sexually mature New Zealand White rabbits and evaluated for possible associations with spermatogenic efficiency as well as with volume density and number of Leydig cells. Testicular tissue was processed histologically and histometry was performed in order to quantify germ cells, Sertoli cells and Leydig cells. Spermatogenic efficiency, reported as the ratios among germ cells (spermatogonia, primary spermatocytes and round spermatids) and by the ratio of germ cells to Sertoli cells, was not associated with testosterone levels. However, Leydig cell parameters such as number of Leydig cells per gram of testis, total number of Leydig cells per testis and percent cell volume of Leydig cell nuclei were correlated significantly with testosterone levels. The statistically significant correlation (r = 0.82, P<0.05) observed between testosterone levels and the number of Leydig cells per gram of testis suggests that, in the rabbit, the latter parameter can serve as a criterion for monitoring testosterone levels in this species under normal conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two variants (A and B) of the widely employed Walker 256 rat tumor cells are known. When inoculated sc, the A variant produces solid, invasive, highly metastasizing tumors that cause severe systemic effects and death. We have obtained a regressive variant (AR) whose sc growth is slower, resulting in 70-80% regression followed by development of immunity against A and AR variants. Simultaneously with the beginning of tumor regression, a temporary anemia developed (~8 days duration), accompanied by marked splenomegaly (~300%) and changes in red blood cell osmotic fragility, with mean corpuscular fragility increasing from 4.1 to 6.5 g/l NaCl. The possibility was raised that plasma factors associated with the immune response induced these changes. In the present study, we identify and compare the osmotic fragility increasing activity of plasma fractions obtained from A and AR tumor bearers at different stages of tumor development. The results showed that by day 4 compounds precipitating in 60% (NH4)2SO4 and able to increase red blood cell osmotic fragility appeared in the plasma of A and AR tumor bearers. Later, these compounds disappeared from the plasma of A tumor bearers but slightly increased in the plasma of AR tumor bearers. Furthermore, by day 10, compounds precipitating between 60 and 80% (NH4)2SO4 and with similar effects appeared only in plasma of AR tumor bearers. The salt solubility, production kinetics and hemolytic activity of these compounds resemble those of the immunoglobulins. This, together with their preferential increase in rats bearing the AR variant, suggest their association with an immune response against this tumor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A continuous assay using internally quenched fluorescent peptides with the general sequence Abz-peptidyl-(Dnp)P-OH (Abz = ortho-aminobenzoic acid; Dnp = 2,4-dinitrophenyl) was optimized for the measurement of angiotensin I-converting enzyme (ACE) in human plasma and rat tissues. Abz-FRK(Dnp)P-OH, which was cleaved at the Arg-Lys bond by ACE, was used for the enzyme evaluation in human plasma. Enzymatic activity was monitored by continuous recording of the fluorescence (lambdaex = 320 nm and lambdaem = 420 nm) at 37ºC, in 0.1 M Tris-HCl buffer, pH 7.0, with 50 mM NaCl and 10 µM ZnCl2. The assays can be performed directly in the cuvette of the fluorimeter and the hydrolysis followed for 5 to 10 min. ACE measurements in the plasma of 80 healthy patients with Hip-His-Leu and with Abz-FRK(Dnp)P-OH correlated closely (r = 0.90, P < 0.001). The specificity of the assay was demonstrated by the complete inhibition of hydrolysis by 0.5 µM lisinopril or captopril. Abz-FRK(Dnp)P-OH cleavage by ACE was monitored in rat lung, kidney, heart, and liver homogenates in the presence of a cocktail of inhibitors containing trans-epoxy-succinyl-L-leucylamido-(4-guanido)-butene, pepstatin, phenyl-methylsulfonyl fluoride, N-tosyl-L-phenylalanyl-chloromethyl ketone, and N-tosyl-lysyl-chloromethyl ketone to prevent undesirable hydrolysis. ACE activity in lung, heart and kidney homogenates, but not in liver homogenates, was completely abolished by 0.5 µM lisinopril or captopril. The advantages of the method are the procedural simplicity and the high sensitivity providing a rapid assay for ACE determinations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The question of whether HIV-1 RNA in cerebrospinal fluid (CSF) is derived from viral replication in the central nervous system or simply reflects the transit of infected lymphocytes from the blood compartment has long been a matter of debate. Some studies found no correlation between CSF and plasma viral load, whereas others did. The lack of a correlation between the two compartments suggests that the presence of HIV-1 RNA is not simply due to the passive passage of the virus from blood to CSF but rather due to intrathecal replication. To evaluate the correlation between plasma and CSF HIV-1 RNA levels and to identify situations in which there is no correlation between the two compartments, seventy patients were prospectively studied. The association between CSF and plasma viral load was evaluated in the total population and in subgroups of patients with similar characteristics. A correlation between the CSF and plasma compartments was observed for patients undergoing highly active antiretroviral therapy (HAART), those with a CD4 T lymphocyte count lower than 200 cells/mm³, and those with increased CSF protein content. On the other hand, no correlation was observed for patients without adequate virological control, who had a CD4 count higher than 200 cells/mm³ and who did not use HAART. The correlation between the two compartments observed in some patients suggests that CSF HIV-1 RNA levels may reflect plasma levels in these subjects. In contrast, the lack of a correlation between the two compartments in patients who were not on HAART and who had normal CSF proteins and a poor virological control possibly indicates compartmentalization of the virus in CSF and, consequently, plasma-independent intrathecal viral replication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malaria remains an important health problem in tropical countries like Brazil. Thrombocytopenia is the most common hematological disturbance seen in malarial infection. Oxidative stress (OS) has been implicated as a possible mediator of thrombocytopenia in patients with malaria. This study aimed to investigate the role of OS in the thrombocytopenia of Plasmodium vivax malaria through the measurement of oxidant and antioxidant biochemical markers in plasma and in isolated platelets. Eighty-six patients with P. vivax malaria were enrolled. Blood samples were analyzed for total antioxidant and oxidant status, albumin, total protein, uric acid, zinc, magnesium, bilirubin, total thiols, glutathione peroxidase (GPx), malondialdehyde (MDA), antibodies against mildly oxidized low-density lipoproteins (LDL-/nLDL ratio) and nitrite/nitrate levels in blood plasma and GPx and MDA in isolated platelets. Plasma MDA levels were higher in thrombocytopenic (TCP) (median 3.47; range 1.55-12.90 µmol/L) compared with the non-thrombocytopenic (NTCP) patients (median 2.57; range 1.95-8.60 µmol/L). Moreover, the LDL-/nLDL autoantibody ratio was lower in TCP (median 3.0; range 1.5-14.8) than in NTCP patients (median 4.0; range 1.9-35.5). Finally, GPx and MDA were higher in the platelets of TPC patients. These results suggest that oxidative damage of platelets might be important in the pathogenesis of thrombocytopenia found in P. vivax malaria as indicated by alterations of GPx and MDA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biodistribution and removal from plasma (measured as fractional clearance rate, FCR, per hour) of native and oxidatively modified 99mtechnetium-labeled ß-very low density lipoprotein (99mTc-ß-VLDL) were investigated in hypercholesterolemic (HC) and control (C) three-month old New Zealand rabbits. The intracellular accumulation of ß-VLDL labeled with 99mTc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized ß-VLDL (99mTc-ox-ß-VLDL) was cleared from the circulation faster (0.362 ± 0.070/h) than native ß-VLDL (99mTc-nat-ß-VLDL, 0.241 ± 0.070/h). In contrast, the FCR of 99mTc-ox-ß-VLDL in HC rabbits was lower (0.100 ± 0.048/h) than that of 99mTc-nat-ß-VLDL (0.163 ± 0.043/h). The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 ± 0.071% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.116 ± 0.057% injected dose/g tissue for 99mTc-ox-ß-VLDL) than in C rabbits (0.301 ± 0.113% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.305 ± 0.149% injected dose/g tissue for 99mTc-ox-ß-VLDL). The uptake of 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL by atherosclerotic aorta lesions isolated from HC rabbits (99mTc-nat-ß-VLDL: 0.033 ± 0.012% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.039 ± 0.017% injected dose/g tissue) was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99mTc-nat-ß-VLDL: 0.023 ± 0.010% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.019 ± 0.010% injected dose/g tissue). However, 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more 99mTc-ox-ß-VLDL than 99mTc-nat-ß-VLDL. These results indicate that in cholesterol-fed rabbits 99mTc-ox-ß-VLDL is slowly cleared from plasma and accumulates in atherosclerotic lesions. However, although the extent of in vitro uptake of 99mTc-ox-ß-VLDL by macrophages was high, the in vivo accumulation of this radiolabeled lipoprotein by atherosclerotic lesions did not differ from that of 99mTc-nat-ß-VLDL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the method described here is to remove hemoglobin, the major contaminant in the bovine plasma obtained from slaughterhouses, by adding a mixture of 19% cold ethanol and 0.6% chloroform, followed by fibrinogen and globulin precipitation by the Cohn method and nonspecific hemagglutinin by thermocoagulation. The experimental volume of bovine plasma was 2,000 ml per batch. Final purification was performed by liquid chromatography using the ion-exchange gel DEAE-Sepharose FF. The bovine albumin thus obtained presented > or = 99% purity, a yield of 25.0 ± 1.2 g/l plasma and >71.5% recovery. N-acetyl-DL-tryptophan (0.04 mmol/g protein) and sodium caprylate (0.04 mmol/g protein) were used as stabilizers and the final concentration of albumin was adjusted to 22.0% (w/v), pH 7.2 to 7.3. Viral inactivation was performed by pasteurization for 10 h at 60°C. The bovine albumin for the hemagglutination tests used in immunohematology was submitted to chemical treatment with 0.06% (w/v) glutaraldehyde and 0.1% (w/v) formaldehyde at 37°C for 12 h to obtain polymerization. A change in molecular distribution was observed after this treatment, with average contents of 56.0% monomers, 23.6% dimers, 12.2% trimers and 8.2% polymers. The tests performed demonstrated that this polymerized albumin enhances the agglutination of Rho(D)-positive red cells by anti-Rho(D) serum, permitting and improving visualization of the results.