52 resultados para Osteryoung Square Wave Voltammetry

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents an electroanalytical method for the determination of moxifloxacin (MOXI) in tablets by its interaction with Cu(II) ion and subsequent electrochemical reduction at hanging mercury drop electrode (HMDE). A well-defined reduction peak at -0.21 V vs. Ag/AgCl in Phosphate buffer 0.04 mol L-1 pH 8.0 was observed for the complex reduction MOXI-Cu(II), using square-wave voltammetry (SWV). Using a 10 s of accumulation time at -0.40 V was found a limit detection of 3.60x10-8 mol l-1. The obtained results have shown good agreement with those obtained by spectrophotometric method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl)) in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996) for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The theoretical aspects of square wave voltammetry were discussed. Reversible, irreversible and quase-reversible electrode reactions were analyzed and the correlations between parameters like frequency, period, square wave potential and amplitude were showed. In this way, diagnostic relationships allow to characterize the electrode process. The analytical applications were discussed in base of the increment in the analytical response (current) due to the characteristics of the developed equations and the unique mode of collecting the electrode response, i.e., the direct and reverse signals. Finally, recent advances in the basic theory, as the applications to the hydrodynamic electrode and the ultramicroelectrode were also analyzed, and the multiple pulses square wave voltammetry was also introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical behavior of paraquat on Pt, Au and carbon fiber ultramicroelectrodes were studied in laboratory samples by square wave voltammetry at high frequencies. The results showed two reversible peaks for paraquat reduction, in agreement to the literature data. The first peak was associated to the reduction of paraquat molecule in solution, with the further adsorption of the intermediate on the electrode surface. This adsorbed species undergoes to electroreduction in a reaction associated to the second voltammetric peak. The variation in pH and square wave parameters showed the best conditions to reduce paraquat as pH 5.0, frequency as high as 1000 s-1, scan increment of 2 mV and square wave amplitude of 50 mV. At such conditions, a variation of paraquat concentrations from 4.3 x 10-6 to 1.66 x 10-4 mol L-1 presented values for the detection limit equal to 3.9, 6.2 and 20.3 ppb on Pt, Au and carbon, respectively, at 1000 s-1. These values are quite below17 the allowed limit of paraquat in drinking water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new way for the construction of silver electrodes utilizing recordable CDs. The new electrodes were explored for the quantification of chloride (by potentiometry/FIA), cyanide (by amperometry/FIA) and for lead analysis (by square wave voltammetry). For the flowing measurements, a digital multimeter, connected to a microcomputer (via RS 232 interface) was used to collect directly the potential signal (for Cl- measurements) or to take the output signal from a potentiostat (for CN- measurements). The square wave voltammetry analysis was performed in a commercial instrument. The results shown good performance of the new electrodes and the detection limit (s/n = 3) attained for these three analytes were: 0.2, 50, and 200 µg L-1 for Pb2+, Cl-, and CN- respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The anodic voltammetric behavior of 4-chlorophenol (4-CF) in aqueous solution has been studied on a Boron-doped diamond electrode using square wave voltammetry (SWV). After optimization of the experimental conditions, 4-CF was analyzed in pure and natural waters using a Britton-Robinson buffer with pH = 6.0 as the supporting electrolyte. Oxidation occurs at 0.80 V vs Ag/AgCl in a two-electron process controlled by adsorption of the species. The detection limits obtained were 6.4 µg L-1 in pure water and 21.5 µg L-1 for polluted water taken from a local creek, respectively. The combination of square wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to discuss some selected applications of square wave voltammetry published in the last five years. The applications focused here cover several electroanalytical fields such as: determination of pesticides; molecules with biological activity; metals and other environmental pollutants. Special attention is given to the work developed in the Grupo de Materiais Eletroquímicos e Métodos Eletroanalíticos - IQSC - USP concerning the utilization of square wave voltammetry, with different kinds of electrodes, for the determination of pesticides in natural waters and active principles in pharmaceutical formulations. The new methodology is simple, fast and sensitive when compared with the traditional ones such as chromatography and spectrophotometry. The satisfactory results obtained provide alternative procedures for the quality control of drugs and the monitoring of pesticides in natural environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work reports the use of square wave voltammetry (SWV) to analyse the electrochemical reduction of dichlorvos (2, 2-dichlorovinyl-dimethylphosphate) in spiked pure and natural waters. SWV measurements were carried out in 0.5 mol L-1 Na2SO4 aqueous solutions at pH 5, prepared with water originated from three different sources, namely, one sample of purified water and others from two urban creeks in São Carlos County. In all cases, two reduction peaks were observed, at potentials of -0.15 and -1.05 V vs Ag/AgCl, with both current and potential being dependent on pesticide concentration. This allowed the calculation of the following detection limits: 1.0, 2.5 and 3.0x10-8 mol L-1 for purified, Gregorio creek and Monjolinho creek waters, respectively, in a working range between 2.0x10-7 and 1.4x10-6 mol L-1. Recovery measurements found values higher than 80% in all cases, for an added concentration of 4.0 x 10-7 mol L-1 of dichlorvos in each solution. All analytical experiments were performed in triplicate and showed a standard deviation always less than 3%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A boron-doped diamond electrode is used for determination of Mn(II) in atmospheric particulate matter by square wave cathodic stripping voltammetry. The analytical curve was linear for Mn(II) concentrations between 5.0 and 37.5 µg L-1, with quantification limit of 3.6 µg L-1. The precision was evaluated by the relative standard deviation, with values between 5.1% and 9.3%. The electrode is free of adsorption, minimizing memory effects. Samples collected in the workplace atmosphere of a foundry had Mn(II) concentrations between 0.4 and 4 µg m-3. No significant differences were observed between the proposed method and inductively coupled plasma optical emission spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work a simple and versatile procedure is described for treating water samples using small polypropylene (PP) vials (4 mL) for determining heavy metals by square wave voltammetry (SWV). This procedure involves treatment with nitric acid (0.2 mol L-1) and boiling in a water-bath (~ 100 ºC). This process is completed after one hour and allows the pretreatment of several samples simultaneously. The accuracy was estimated using addition/recovery studies and certified water sample analysis, yielding an agreement near to 100%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the development of multiple square wave voltammetry and the possibilities of its use for electroanalytical determinations of organic and inorganic compounds with the improvement of the signal-to-noise ratios and detection limits 2-3 orders of magnitude lower than those obtained with conventional square wave voltammetry. The theoretical aspects and analytical applications were demonstrated as an increased analytical response (current) and application of different pulse modes for different redox processes. Preliminary results obtained for several redox systems using different electrode surfaces are shown, demonstrating also that MSWV represents an excellent alternative for the determination of ultra-traces of organic and inorganic compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The supply of drinking water in the Metropolitan Area of São Paulo City has been a great and serious challenge in the latest years. This work demonstrates the viability of the evaluation of the degree of contamination of the water reservoirs using analytical procedures, which allow the analysis of several compounds at relatively low cost: stripping square wave voltammetry (SSWV) and capillary zone electrophoresis with contactless conductivity detection (CZE-CCD). The results of ionic composition indicated significant contamination of the Guarapiranga water system by human activities on the reservoir banks. In fact, the Guavirutuba and Itupu streams presented high concentrations of phosphate and ammonium ions. This can be directly related to misuse and unruled occupation of the soil and precarious sanitary infrastructure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the development of electroanalytical methodologies for the determination of atrazine, ametrine and simazine by square wave voltammetry on a mercury electrode. For pure atrazine and pure ametrine, the detection limits (DL) were 3.7 and 4.3 µg L-1, respectively, while they increased to 4.8 and 6.5 µg L-1 in the presence of 3.0 x 10-6 mol L-1 of the other component (a mathematical deconvolution program was used in the mixture cases). The voltammetric response for simazine could not be separated from that of atrazine and measurements were carried out only in pure simazine solutions (DL: 7.5 µg L-1).