23 resultados para Noise -- Measurement -- Catalonia -- Sarrià de Ter
em Scielo Saúde Pública - SP
Resumo:
The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.
Resumo:
In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.
Resumo:
OBJECTIVE To evaluate the audiometric profile of civilian pilots according to the noise exposure level. METHODS This observational cross-sectional study evaluated 3,130 male civilian pilots aged between 17 and 59 years. These pilots were subjected to audiometric examinations for obtaining or revalidating the functional capacity certificate in 2011. The degree of hearing loss was classified as normal, suspected noise-induced hearing loss, and no suspected hearing loss with other associated complications. Pure-tone air-conduction audiometry was performed using supra-aural headphones and acoustic stimulus of the pure-tone type, containing tone thresholds of frequencies between 250 Hz and 6,000 Hz. The independent variables were professional categories, length of service, hours of flight, and right or left ear. The dependent variable was pilots with suspected noise-induced hearing loss. The noise exposure level was considered low/medium or high, and the latter involved periods > 5,000 flight hours and > 10 years of flight service. RESULTS A total of 29.3% pilots had suspected noise-induced hearing loss, which was bilateral in 12.8% and predominant in the left ear (23.7%). The number of pilots with suspected hearing loss increased as the noise exposure level increased. CONCLUSIONS Hearing loss in civilian pilots may be associated with noise exposure during the period of service and hours of flight.
Resumo:
The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.
Resumo:
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
Primary cultures of cardiomyocytes represent a useful model for analyzing cardiac cell biology as well as pathogenesis of several cardiovascular disorders. Our aim was to standardize protocols for determining the damage of cardiac cells cultured in vitro by measuring the creatine kinase and its cardiac isotype and lactate dehydrogenase activities in the supernatants of mice cardiomyocytes submitted to different protocols of cell lysis. Our data showed that due to its higher specificity, the cardiac isotype creatine kinase was the most sensitive as compared to the others studied enzymatic markers, and can be used to monitor and evaluate cardiac damage in in vitro assays.
Resumo:
Leprosy is an infectious and contagious spectral disease accompanied by a series of immunological events triggered by the host response to the aetiologic agent, Mycobacterium leprae . The induction and maintenance of the immune/inflammatory response in leprosy are linked to multiple cell interactions and soluble factors, primarily through the action of cytokines. The purpose of the present study was to evaluate the serum levels of tumour necrosis factor (TNF)-α and its soluble receptors (sTNF-R1 and sTNF-R2) in leprosy patients at different stages of multidrug treatment (MDT) in comparison with non-infected individuals and to determine their role as putative biomarkers of the severity of leprosy or the treatment response. ELISA was used to measure the levels of these molecules in 30 healthy controls and 37 leprosy patients at the time of diagnosis and during and after MDT. Our results showed increases in the serum levels of TNF-α and sTNF-R2 in infected individuals in comparison with controls. The levels of TNF-α, but not sTNF-R2, decreased with treatment. The current results corroborate previous reports of elevated serum levels of TNF-α in leprosy and suggest a role for sTNF-R2 in the control of this cytokine during MDT.
Resumo:
The growing demand and the degree of patient care in oncological outpatient services, as well as the complexity of treatment have had an impact on the workload of nurses. This study aimed at measuring the workload and productivity of nurses in an oncological outpatient service. An observational study using a work sampling technique was conducted and included seven nurses working in an oncological outpatient service in the south-eastern region of Brazil. A total of 1,487 intervention or activity samples were obtained. Nurses used 43.2% of their time on indirect care, 33.2% on direct care, 11.6% on associated activities, and 12% on personal activities. Their mean productivity was 88.0%. The findings showed that nurses in this service spend most of their time in indirect care activities. Moreover, the productivity index in this study was above that recommended in the literature.
Resumo:
This work aimed to measure and analyze total rainfall (P), rainfall intensity and five-day antecedent rainfall effects on runoff (R); to compare measured and simulated R values using the Soil Conservation Service Curve Number method (CN) for each rainfall event; and to establish average R/P ratios for observed R values. A one-year (07/01/96 to 06/30/97) rainfall-runoff data study was carried out in the Capetinga watershed (962.4 ha), located at the Federal District of Brazil, 47° 52' longitude West and 15° 52' latitude South. Soils of the watershed were predominantly covered by natural vegetation. Total rainfall and runoff for the period were 1,744 and 52.5 mm, respectively, providing R/P of 3% and suggesting that watershed physical characteristics favored water infiltration into the soil. A multivariate regression analysis for 31 main rainfall-runoff events totaling 781.9 and 51.0 mm, respectively, indicated that the amount of runoff was only dependent upon rainfall volume. Simulated values of total runoff were underestimated about 15% when using CN method and an area-weighted average of the CN based on published values. On the other hand, when average values of CN were calculated for the watershed, total runoff was overestimated about 39%, suggesting that CN method shoud be used with care in areas under natural vegetation.
Resumo:
Evaluation of root traits may be facilitated if they are assessed on samples of the root system. The objective of this work was to determine the sample size of the root system in order to estimate root traits of common bean (Phaseolus vulgaris L.) cultivars by digital image analysis. One plant was grown per pot and harvested at pod setting, with 64 and 16 pots corresponding to two and four cultivars in the first and second experiments, respectively. Root samples were scanned up to the completeness of the root system and the root area and length were estimated. Scanning a root sample demanded 21 minutes, and scanning the entire root system demanded 4 hours and 53 minutes. In the first experiment, root area and length estimated with two samples showed, respectively, a correlation of 0.977 and 0.860, with these traits measured in the entire root. In the second experiment, the correlation was 0.889 and 0.915. The increase in the correlation with more than two samples was negligible. The two samples corresponded to 13.4% and 16.9% of total root mass (excluding taproot and nodules) in the first and second experiments. Taproot stands for a high proportion of root mass and must be deducted on root trait estimations. Samples with nearly 15% of total root mass produce reliable root trait estimates.