16 resultados para Mobile mammography
em Scielo Saúde Pública - SP
Resumo:
The use of Mobile and Wireless Information Technologies (MWIT) for provisioning public services by a government is a relatively recent phenomenon. This paper evaluates the results of MWIT adoption by IBGE (The Brazilian Institute of Geography and Statistics) through a case study. In 2007, IBGE applied 82,000 mobile devices (PDAs) for data gathering in a census operation in Brazil. A set of challenges for a large scale application of MWIT required intensive work involving innovative working practices and service goals. The case reveals a set of outputs of this process, such as time and cost reductions in service provision, improved information quality, staff training and increased organizational effectiveness and agility.
Resumo:
OBJECTIVE: To evaluate knowledge, attitude and practice related to mammography among women users of local health services, identifying barriers to its performance. METHODS: A total of 663 women were interviewed at 13 local health centers in a city of Southeastern Brazil, in 2001. Interviewees were randomly selected at each center and they were representative from different socioeconomic conditions. The number of interviewees at each center was proportional to monthly mean appointments. For data analysis, answers were described as knowledge, attitude, practice and their respective adequacies and then they were correlated with control variables through the chi-square test. RESULTS: Only 7.4% of the interviewees had adequate knowledge on mammography, while 97.1% of women had an adequate attitude. The same was seen for the practice of mammography that was adequate in 35.7% of the cases. The main barrier to mammography was lack of referral by physicians working at the health center (81.8%). There was an association between adequacy of attitude and five years or more of education and being married. There was also an association between adequacy of mammography practice and being employed and family income up to four minimum wages. CONCLUSIONS: Women users of local health services had no adequate knowledge and practice related to mammography despite having an adequate attitude about this exam.
Resumo:
OBJECTIVE To assess findings of mammography of and interventions resulting from breast cancer screening in women aged 40-49 years with no increased risk (typical risk) of breast cancer. METHODS This cross-sectional study evaluated women aged 40-49 years who underwent mammography screening in a mastology reference center in Recife, PE, Northeastern Brazil, between January 2010 and October 2011. Women with breast-related complaints, positive findings in the physical examination, or high risk of breast cancer were excluded. RESULTS The 1,000 mammograms performed were classified into the following Breast Imaging-Reporting and Data System (BI-RADS) categories BI-RADS 0, 232; BI-RADS 1, 294; BI-RADS 2, 294; BI-RADS 3, 16; BI-RADS 4A, 2; BI-RADS 5, 1. There was one case of grade II invasive ductal carcinoma and various interventions, including 469 ultrasound scans, 53 referrals to mastologists, 11 cytological examinations, and 8 biopsies. CONCLUSIONS Mammography screening in women aged 40-49 years with typical risk of breast cancer led to the performance of other interventions. However, it also resulted in increased costs without demonstrable efficacy in decreasing mortality.
Resumo:
INTRODUCTION : The aim of this study was to report the experience of an epidemiological field survey for which data were collected and analyzed using tablets. METHODS : The devices used Epi Info 7 (Android version), which has been modeled a database with variables of the traditional form. RESULTS : Twenty-one households were randomly selected in the study area; 75 residents were registered and completed household interviews with socioeconomic and environmental risk variables. CONCLUSIONS : This new technology is a valuable tool for collecting and analyzing data from the field, with advantageous benefits to epidemiological surveys.
Resumo:
OBJECTIVES To validate an instrument to assess quality of mobile emergency pre-hospital care. METHOD A methodological study where 20 professionals gave their opinions on the items of the proposed instrument. The analysis was performed using Kappa test (K) and Content Validity Index (CVI), considering K> 0.80 and CVI ≥ 0.80. RESULTS Three items were excluded from the instrument: Professional Compensation; Job Satisfaction and Services Performed. Items that obtained adequate K and CVI indexes and remained in the instrument were: ambulance conservation status; physical structure; comfort in the ambulance; availability of material resources; user/staff safety; continuous learning; safety demonstrated by the team; access; welcoming; humanization; response time; costumer privacy; guidelines on care; relationship between professionals and costumers; opportunity for costumers to make complaints and multiprofessional conjunction/actuation. CONCLUSION The instrument to assess quality of care has been validated and may contribute to the evaluation of pre-hospital care in mobile emergency services.
Resumo:
Studies on lower attines are scarce, especially on nesting and foraging ecology and behavior. This study aimed to contribute to the knowledge of an Attini in dunes ecosystems through the description of density and spatial distribution of Mycetophylax simplex (Emery, 1887) nests in a strip of mobile dunes in the Praia Grande beach, Torres, northern coast of Rio Grande do Sul, Brazil. The density and spatial distribution of nests were estimated in four plots of 2,500 m² each, in which were found 20, 209, 284 and 324 nests, with average densities of 0.01 nests/m², 0.09, 0.11 and 0.13 nests/m², respectively. The nests were found near to the vegetation and showed clumped distribution. The density and distribution pattern of the nests seem to be related to the availability of nesting places and foraging resources.
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies.
Resumo:
Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
Resumo:
Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.
Resumo:
RESUMO A tomada de decisão é uma das dimensões essenciais da formação do profissional da saúde, como mencionado nas atuais Diretrizes Curriculares Nacionais do Curso de Graduação em Medicina. O processo decisório, no âmbito da saúde, envolve diferentes aspectos, incluindo os elementos (bio)éticos. Nesse sentido, pesquisas que investiguem a tomada de decisão em (bio)ética poderão elucidar passos ainda não completamente esclarecidos, permitindo uma construção mais efetiva das competências em (bio)ética, na graduação e na pós-graduação. Diante desta perspectiva, o objetivo deste estudo é explorar possibilidades de uso do Mobile Eye Tracking para o estudo do papel da atenção visual – durante a exibição de filmes de cinema – no processo decisório em (bio)ética.
Resumo:
Parameters such as tolerance, scale and agility utilized in data sampling for using in Precision Agriculture required an expressive number of researches and development of techniques and instruments for automation. It is highlighted the employment of methodologies in remote sensing used in coupled to a Geographic Information System (GIS), adapted or developed for agricultural use. Aiming this, the application of Agricultural Mobile Robots is a strong tendency, mainly in the European Union, the USA and Japan. In Brazil, researches are necessary for the development of robotics platforms, serving as a basis for semi-autonomous and autonomous navigation systems. The aim of this work is to describe the project of an experimental platform for data acquisition in field for the study of the spatial variability and development of agricultural robotics technologies to operate in agricultural environments. The proposal is based on a systematization of scientific work to choose the design parameters utilized for the construction of the model. The kinematic study of the mechanical structure was made by the virtual prototyping process, based on modeling and simulating of the tension applied in frame, using the.
Resumo:
Since the advent of mechanized farming and intensive use of agricultural machinery and implements on the properties, the soil began to receive greater load of machinery traffic, which can cause increased soil compaction. The aim of this study was to evaluate the spatial variability of soil mechanical resistance to penetration (RP) in the layers of 0.00-0.10, 0.10-0.20, 0.20-0.30 and 0.30-0.40m, using geostatistics in an area cultivated with mango in Haplic Vertisol of the northeastern semi-arid, with mobile unit equipped with electronic penetrometer. The RP data was collected in 56 points from an area of 3 ha, and random soil samples were collected to determine the soil moisture and texture. For RP data analysis we used descriptive statistics and geostatistics. The soil mechanical resistance to penetration presented increased variability, with adjustment of the spherical and exponential semivariograms in the layers. We found that 42% of the area in the layer of 0.10-0.20m showed RP values above 2.70 MPa. Maximum values of RP were found in the layer of 0.19-0.27m, predominantly in 56% of the area.
Resumo:
An Autonomous Mobile Robot battery driven, with two traction wheels and a steering wheel is being developed. This Robot central control is regulated by an IPC, which controls every function of security, steering, positioning localization and driving. Each traction wheel is operated by a DC motor with independent control system. This system is made up of a chopper, an encoder and a microcomputer. The IPC transmits the velocity values and acceleration ramp references to the PIC microcontrollers. As each traction wheel control is independent, it's possible to obtain different speed values for each wheel. This process facilities the direction and drive changes. Two different strategies for speed velocity control were implemented; one works with PID, and the other with fuzzy logic. There were no changes in circuits and feedback control, except for the PIC microcontroller software. Comparing the two different speed control strategies the results were equivalent. However, in relation to the development and implementation of these strategies, the difficulties were bigger to implement the PID control.