4 resultados para MULTICOMMUTATION

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow system based on multicommutation and binary sampling process was developed to implement the sample zone trapping technique in order to increase the spectrophotometric analytical range and to improve sensitivity. The flow network was designed with active devices in order to provide facilities to determine sequentialy analyte with a wide concentration range, employing a single pumping channel to propel sample and reagents solutions. The procedure was employed to determine ortophosphate ions in water samples of river and waste. Profitable features such as an analytical throughput of 60 samples determination per hour, relative standard deviation (r.s.d.) of 2% (n = 6) for a typical sample with concentration of 2.78 mg/L were achieved. By applying the paired t-test no significant difference at 95% confidence level was observed between the results obtained with the proposed system and those of the usual flow injection system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automatic flow procedures based on the multicommutation concept, dedicated to the determination of 3-hydroxybutyrate, glucose and cholesterol are proposed. The enzymes were immobilized on glass beads and packed into mini-columns that were coupled to a flow system. Sampling throughputs of 55, 40 and 40 determinations per hour, linear response from 10 to 150, 50 to 600, 25 to 125 mg L-1, detection limits of 1.5, 14 and 4 mg L-1 and relative standard deviations of 1, 2 and 2% for 3-hydroxybutyrate, glucose and cholesterol, respectively, were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A binary sampling flow analysis system equipped with gas diffusion cell was developed for NH4+ and/or NH2Cl determination in wastewater and disinfection products samples based on the Berthelot reaction of the NH2Cl diffused through the semi-permeable PTFE membrane. The effect of the analytical conditions related to the reaction and flow parameters were evaluated and N-NH4+ and N-NH2Cl were determined in concentration ranges from 0.17 to 5 mg L-1 and from 0.5 to 14.5 mg L-1, respectively. Limits of detection (3σ) of 50 and 140 µg L-1 for N-NH4+ and N-NH2Cl were calculated, respectively, and RSD of 5 and 2% were calculated for 10 consecutive determinations of N-NH4+ (1 and 3 mg L-1) and N-NH2Cl (3 and 9 mg L-1), respectively with 30 determinations h-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.