25 resultados para HR- CS GF AAS

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 ºC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Health Surveillance Agency (ANVISA) established in the decree number 54 maximum allowed levels for Ni and Pb in mineral and natural waters at 20 µg L-1 and 10 µg L-1, respectively. For screening analysis purposes, the high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS FAAS) was evaluated for the fast-sequential determination of nickel and lead in mineral waters.Two atomic lines for Ni (232.003 nm - main and 341.477 nm - secondary) and Pb (217.0005 nm - main and 283.306 nm - secondary) at different wavelength integrated absorbance (number of pixels) were evaluated. Sensitivity enhanced with the increase of the number of pixels and with the summation of the atomic lines absorbances. The main figures of merit associated to the HR-CS FAAS technique were compared with that obtained by line-source flame atomic absorption spectrometry (LS FAAS). Water samples were pre-concentrated about 5-fold by evaporation before analysis. Recoveries of Pb significantly varied with increased wavelength integrated absorbance. Better recoveries (92-93%) were observed for higher number of pixels at the main line or summating the atomic lines (90-92%). This influence was irrelevant for Ni, and recoveries in the 92-104% range were obtained in all situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste estudo, cromatografia de exclusão por tamanho (SEC) com detecção por UV e detecção off-line por espectrometria de absorção atômica em forno de grafite (GF AAS) foi usada para investigar a associação de cobre a espécies de alta massa molecular (HMW) e baixa massa molecular (LMW) presentes na polpa de açaí (Euterpe oleracea Mart.). A concentração total de cobre obtida nos digeridos da polpa de açaí foi 10,5 µg g-1. Cobre foi encontrado associado às frações de HMW e LMW, correspondentes às massas moleculares de 28,7, 2,6 e 0,43 kDa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study assessed selenium concentrations in the muscle tissues and liver samples of three fish species and in the soft tissues of a mussel species. The samples were analyzed by GF-AAS using Zeeman background correction. Selenium in the muscle samples was higher in carnivorous fish. The liver of all studied fish species presented higher selenium concentrations than the muscle. The fish species presented a high positive correlation between their total length and selenium concentration. A significant correlation was observed between the selenium concentration in the mussel soft tissues and the condition index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper present an overview of way covered for the spectrometry of atomic absorption (AAS), tracing a line of the historical events in its development and its establishment as a multielement technique. Additionally, the efforts carried by through several researchers in the search for the instrumental evolution, the advances, advantages, limitations, and trends of this approach are related. Several works focusing its analytical applications are cited employing simultaneous multielement determination by flame (FAAS) and/or graphite furnace (GF AAS), and fast sequential multielement determination using FAAS are reported in the present review.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the development of methods for the determination of Pb and Mn in fishes by GF AAS after solubilization with tetramethylamonium hidroxide. The optimization of the operational conditions and the choice of modifier were made using multivariated optimization. Analytical Figures of Merit were adequately to propose. The Limit of Quantification obtained were 150 and 18.5 µg kg-1 to Mn and Pb, respectively. No significant difference was found between the slope values obtained for the aqueous and standard addition calibration curves. The D.P.R. was always lower than 12% and the analysis of the SRM NRCC TORT2 showed 80-120% of recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A influência de digeridos e suspensões de açúcar no comportamento térmico de As usando Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Ni(NO3)2 como modificadores químicos foi investigada. Influência de 0,2%, 5%, 10% e 35% (v/v) HNO3 na calibração (1,00 - 10,0 µg As L-1) também foi feita. Um volume de 20 µL de amostra mais 5 µL Pd ou 5 µL Pd + 3 µL Mg, ou 20 µL Ni foi injetado no atomizador do GF AAS. Para cada modificador, temperaturas de pirólise e atomização foram avaliadas por meio de curvas de pirólise e de atomização, respectivamente. Para suspensão de açúcar, temperaturas de pirólise e atomização (Tp, Ta) obtidas foram: sem modificador (400° C, 2000° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (1600° C, 2200° C). Os valores para digeridos de açúcar foram: sem modificador (400° C, 2200° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (600° C, 2200° C). Paládio foi selecionado como o melhor modificador químico. O tempo de vida do tubo de grafte foi de aproximadamente 350 queimas, o RSD (n = 12) para uma amostra típica contendo 5,52 µg As L-1 foi < 2,2% e o limite de detecção foi 2,4 pg As. Recuperações entre 80 e 92% foram encontradas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entre as doenças que ocorrem na cultura da melancia (Citrullus lanatus), a virose ocasionada por Watermelon mosaic virus (WMV) se destaca entre as principais, sendo a resistência genética a forma mais indicada de controle. Dessa forma, é importante o conhecimento do controle genético da resistência que se pretende trabalhar. Objetivando estudar a herança da resistência ao WMV em melancia, foram realizados cruzamentos entre o cultivar Crimson Sweet (CS) suscetível e a linha L26 resistente. Populações segregantes e não segregantes obtidas dos cruzamentos foram inoculadas com um isolado de WMV e avaliadas quanto ao aparecimento de sintomas e à presença do vírus por testes de ELISA indireto contra antissoro específico para WMV. A hipótese de herança monogênica foi avaliada em diferentes graus médios de dominância e pelo método da máxima verossimilhança. Foram obtidas variâncias genética (σ²G), ambiental (σ²E), fenotípica (σ²F2), aditiva (σ²A) e de dominância (σ²D), herdabilidades nos sentidos amplo (h²a) e restrito (h²r). A herança monogênica foi rejeitada. O grau médio de dominância indicou efeito de dominância completa. As herdabilidades no sentido amplo foram baixas; portanto, constatou-se que o controle da resistência a WMV nas populações de melancia estudadas é do tipo oligogênica, com presença de efeitos aditivos e não aditivos e presença de genes maiores e poligenes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies in mice have shown that immunity to malaria sporozoites is mediated primarily by citotoxic T lymphocytes (CTL) specific for epitopes within the circumsporozoite (CS) protein. Humans, had never been shown to generate CTL against any malaria or other parasite protein. The design of a sub-unit vaccine for humans ralies on the epitopes recognized by CTL being identified and polymorphisms therein being defined. We have developed a novel technique using an entire series of overlapping synthetic peptides to define the epitopes of the Plasmodium falciparum CS protein recognized by human CTL and have analyzed the sequence variation of the protein with respect to the identified CTL epitopic domain. We have demonstrated that some humans can indeed generate CTL. against the P. falciparum CS protein. Furthermore, the extent of variation observed for the CTL recognition domain is finite and the combination of peptides necessary for inclusion in a polyvalent vaccine may be small. If ways can be found to increase immune responsiveness, then a vaccine designed to stimulate CS protein-specific CTL activity may prevent malaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple antigen peptide systems (MAPs) allow the incorporation of various epitopes in to a single synthetic peptide immunogen. We have characterized the immune response of BALB/c mice to a series of MAPs assembled with different B and T cell epitopes derived from the Plasmodium vivax circumsporozoite (CS) protein. A B-cell epitope from the central repeat domain and two T-cell epitopes from the amino and carboxyl flanking regions were used to assembled eight different MAPs. An additional universal T cell epitope (ptt-30) from tetanus toxin protein was included. Immunogenicity in terms of antibody responses and in vitro T lymphocyte proliferation was evaluated. MAPs containing B and T cell epitopes induced high titers of anti-peptides antibodies, which recognized the native protein on sporozoites as determined by IFAT. The antibody specificity was also determined by a competitive inhibition assay with different MAPs. A MAP containing the B cell epitope (p11) and the universal epitope ptt-30 together with another composed of p11 and the promiscuous T cell epitope (p25) proved to be the most immunogenic. The strong antibody response and specificity for the cognate protein indicates that further studies designed to assess the potential of these proteins as human malaria vaccine candidates are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A determinação de As por espectrometria de absorção atômica com geração de hidretos (HG-AAS) constitui um método simples, sensível, preciso e de baixo custo. Entretanto, essa técnica requer a pré-redução das espécies de As(V), o que se obtém através do uso de agentes redutores como o KI. Em extratos contendo agentes oxidantes, a pré-redução do As é comprometida, como acontece em extratos obtidos pela aplicação do método BCR (acrônimo francês para Community Bureau of Reference) para a extração sequencial de As em sedimentos. O objetivo deste trabalho foi avaliar as condições de redução do As(V) a As(III), de modo a permitir o uso da HG-AAS para a quantificação do arsênio em extratos obtidos a partir do método BCR. Foram avaliadas condições reacionais utilizando KI, L-cisteína e ácido ascórbico. Para cada uma das etapas de extração do método BCR, diferentes condições de pré-redução possibilitaram a detecção quantitativa do As presente. O uso do método BCR para a extração de arsênio em amostras de sedimentos contaminadas e a aplicação das condições de pré-redução do As(V) selecionadas, seguida pela detecção por HG-AAS, forneceram percentagens de recuperação entre 91 e 99 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A eficiência das estirpes de Bradyrhizobium com características Hup+ (SR e USDA-110), Hup- (29W) e Hup hr (SEMIA-587) foi avaliada em caupi (Vigna unguiculata L.), cultivares IPA-202, BR-3 e VITA-4. Os resultados mostraram que VITA-4, em relação à nodulação, revelou-se superior às demais, e apresentou interação efetiva com as estirpes SEMIA-587 e USDA-110. Entretanto, quanto à eficiência nodular, a combinação IPA-202 x SEMIA-587 alcançou maior atividade da nitrogenase (ARA) com eficiência relativa próxima a 1,0. A ARA detectada nas estirpes SR e SEMIA-587 foi similar, porém, superior às estirpes USDA-110 e 29W, evidenciando que as estirpes Hup+ e Hup hr alcançaram maiores atividades enzimáticas. Os teores de leghemoglobina (Lb) detectados nas estirpes SR e USDA-110 foram positivamente relacionados com as respectivas ARA, contudo, a relação entre teor de Lb e ARA obtido para 29W-Hup- foi variável, sugerindo que, na ausência da hidrogenase, o sistema da nitrogenase fica afetado podendo influir no fluxo de Lb ao bacteróide. A avaliação do teor de N mostrou que não houve diferença entre cultivares, entretanto, foi detectada diferença significativa entre as estirpes. As estirpes Hup+ obtiveram maiores acúmulos de N, evidenciando que os sistemas simbióticos que menos liberam H2, acumulam mais N no hospedeiro.