28 resultados para ELECTRONIC MEASUREMENT

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although postal questionnaires, personal interviewing, and telephone interviewing are the main methods of survey-based research, there is an increasing use of e-mail as a data collection medium. However, little, if any, published Western research in general and that of Turkish in particular have investigated e-mail survey technique from pure survey research perspective. Attempting to develop a framework to assess e-mail as a data collection mean, the purpose of this study is to explore e-mail-based questionnaire technique from complementary angles. To this goal, sample representativeness, data quality, response rates, and advantages and disadvantages of e-mail surveying are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The State Reform processes combined with the emergence and use of Information and Communication Technology (ICT) originated electronic government policies and initiatives in Brazil. This paper dwells on Brazilian e-government by investigating the institutional design it assumed in the state's public sphere, and how it contributed to outcomes related to e-gov possibilities. The analyses were carried out under an interpretativist perspective by making use of Institutional Theory. From the analyses of interviews with relevant actors in the public sphere, such as state secretaries and presidents of public ICT companies, conclusions point towards low institutionalization of e-gov policies. The institutional design of Brazilian e-gov limits the use of ICT to provide integrated public services, to amplify participation and transparency, and to improve public policies management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In studies assessing the effects of a given exposure variable and a specific outcome of interest, confusion may arise from the mistaken impression that the exposure variable is producing the outcome of interest, when in fact the observed effect is due to an existing confounder. However, quantitative techniques are rarely used to determine the potential influence of unmeasured confounders. Sensitivity analysis is a statistical technique that allows to quantitatively measuring the impact of an unmeasured confounding variable on the association of interest that is being assessed. The purpose of this study was to make it feasible to apply two sensitivity analysis methods available in the literature, developed by Rosenbaum and Greenland, using an electronic spreadsheet. Thus, it can be easier for researchers to include this quantitative tool in the set of procedures that have been commonly used in the stage of result validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To estimate worldwide prevalence of chronic low back pain according to age and sex. METHODS We consulted Medline (PubMed), LILACS and EMBASE electronic databases. The search strategy used the following descriptors and combinations: back pain, prevalence, musculoskeletal diseases, chronic musculoskeletal pain, rheumatic, low back pain, musculoskeletal disorders and chronic low back pain. We selected cross-sectional population-based or cohort studies that assessed chronic low back pain as an outcome. We also assessed the quality of the selected studies as well as the chronic low back pain prevalence according to age and sex. RESULTS The review included 28 studies. Based on our qualitative evaluation, around one third of the studies had low scores, mainly due to high non-response rates. Chronic low back pain prevalence was 4.2% in individuals aged between 24 and 39 years old and 19.6% in those aged between 20 and 59. Of nine studies with individuals aged 18 and above, six reported chronic low back pain between 3.9% and 10.2% and three, prevalence between 13.1% and 20.3%. In the Brazilian older population, chronic low back pain prevalence was 25.4%. CONCLUSIONS Chronic low back pain prevalence increases linearly from the third decade of life on, until the 60 years of age, being more prevalent in women. Methodological approaches aiming to reduce high heterogeneity in case definitions of chronic low back pain are essential to consistency and comparative analysis between studies. A standard chronic low back pain definition should include the precise description of the anatomical area, pain duration and limitation level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To describe the methodological characteristics of the studies selected and assess variables associated with sedentary behavior in Brazilian children and adolescents. METHODS For this systematic review, we searched four electronic databases: PubMed, Web of Knowledge, LILACS, SciELO. Also, electronic searches were applied in Google Scholar. A supplementary search was conducted in the references lists of the included articles and in non-indexed journals. We included observational studies with children and adolescents aged from three to 19 years developed in Brazil, presenting analyses of associations based on regression methods and published until September 30, 2014. RESULTS Of the 255 potential references retrieved by the searches, 49 met the inclusion criteria and composed the descriptive synthesis. In this set, we identified a great number of cross-sectional studies (n = 43; 88.0%) and high methodological variability on the types of sedentary behavior assessed, measurement tools and cut-off points used. The variables most often associated with sedentary behavior were “high levels of body weight” (in 15 out of 27 studies; 55.0%) and “lower level of physical activity” (in eight out of 16 studies; 50.0%). CONCLUSIONS The findings of this review raise the following demands to the Brazilian agenda of sedentary behavior research geared to children and adolescents: development of longitudinal studies, validation of measuring tools, establishment of risk cut-offs, measurement of sedentary behavior beyond screen time and use of objective measures in addition to questionnaires. In the articles available, the associations between sedentary behavior with “high levels of body weight” and “low levels of physical activity” were observed in different regions of Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Enteral alimentation is the preferred modality of support in critical patients who have acceptable digestive function and are unable to eat orally, but the advantages of continuous versus intermittent administration are surrounded by controversy. With the purpose of identifying the benefits and complications of each technique, a prospective controlled study with matched subjects was conducted. PATIENTS AND METHODS: Twenty-eight consecutive candidates for enteral feeding were divided into 2 groups (n = 14 each) that were matched for diagnosis and APACHE II score. A commercial immune-stimulating polymeric diet was administered via nasogastric tube by electronic pump in the proportion of 25 kcal/kg/day, either as a 1-hour bolus every 3 hours (Group I), or continuously for 24 hours (Group II), over a 3-day period. Anthropometrics, biochemical measurements, recording of administered drugs and other therapies, thorax X-ray, measurement of abdominal circumference, monitoring of gastric residue, and clinical and nutritional assessments were performed at least once daily. The principal measured outcomes of this protocol were frequency of abdominal distention and pulmonary aspiration, and efficacy in supplying the desired amount of nutrients. RESULTS: Nearly half of the total population (46.4%) exhibited high gastric residues on at least 1 occasion, but only 1 confirmed episode of pulmonary aspiration occurred (3.6%). Both groups displayed a moderate number of complications, without differences. Food input during the first day was greater in Group II (approximately 20% difference), but by the third day, both groups displayed similarly small deficits in total furnished volume of about 10%, when compared with the prescribed diet. CONCLUSIONS: Both administration modalities permitted practical and effective administration of the diet with frequent registered abnormalities but few clinically significant problems. The two groups were similar in this regard, without statistical differences, probably because of meticulous technique, careful monitoring, strict patient matching, and conservative amounts of diet employed in both situations. Further studies with additional populations, diagnostic groups, and dietetic prescriptions should be performed in order to elucidate the differences between these commonly used feeding modalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.