37 resultados para Delivery device

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify risk factors for low birth weight (LBW) among live births by vaginal delivery and to determine if the disappearance of the association between LBW and socioeconomic factors was due to confounding by cesarean section. METHODS: Data were obtained from two population-based cohorts of singleton live births in Ribeirão Preto, Southeastern Brazil. The first one comprised 4,698 newborns from June 1978 to May 1979 and the second included 1,399 infants born from May to August 1994. The risks for LBW were tested in a logistic model, including the interaction of the year of survey and all independent variables under analysis. RESULTS: The incidence of LBW among vaginal deliveries increased from 7.8% in 1978--79 to 10% in 1994. The risk was higher for: female or preterm infants; newborns of non-cohabiting mothers; newborns whose mothers had fewer prenatal visits or few years of education; first-born infants; and those who had smoking mothers. The interaction of the year of survey with gestational age indicated that the risk of LBW among preterm infants fell from 17.75 to 8.71 in 15 years. The mean birth weight decreased more significantly among newborns from qualified families, who also had the highest increase in preterm birth and non-cohabitation. CONCLUSIONS: LBW among vaginal deliveries increased mainly due to a rise in the proportion of preterm births and non-cohabiting mothers. The association between cesarean section and LBW tended to cover up socioeconomic differences in the likelihood of LBW. When vaginal deliveries were analyzed independently, these socioeconomic differences come up again.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine changes in the incidence of vaginal deliveries, cesarean sections, and forceps deliveries and their potential association with fetal, early neonatal, and perinatal mortality rates over time. METHODS: A retrospective study was carried out and the occurrence of deliveries supervised by university services between January 1991 and December 2000 was determined. Data regarding fetal, early neonatal, and perinatal deaths were assessed using obstetric and pediatric records and autopsy reports. RESULTS: Of a total of 33,360 deliveries, the incidence of vaginal deliveries, cesarean sections, and forceps deliveries was relatively steady (around 60, 30, and 10%, respectively) while, at the same time, there was a marked reduction in fetal mortality (from 33.3 to 13.0‰), early neonatal mortality (from 30.6 to 9.0‰), and perinatal mortality (from 56.4 to 19.3‰). CONCLUSIONS: The marked reduction in perinatal mortality rates seen during the study period without an increase in cesarean sections indicates that the decrease in perinatal mortality was not impacted by cesarean section rates. The plausible hypothesis seems to be that the reduction in perinatal mortality of deliveries performed under the supervision of university services was more likely to be associated with better neonatal care rather than the mode of delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between pre-gestational obesity and weight gain with cesarean delivery and labor complications. METHODS: A total of 4,486 women 20-28 weeks pregnant attending general prenatal care clinics of the national health system in Brazil from 1991 to 1995 were enrolled and followed up through birth. Body mass index categories based on prepregnancy weight and total weight gain were calculated. Associations between body mass index categories and labor complications were adjusted through logistic regression analysis. RESULTS: Obesity was present in 308 (6.9%) patients. Cesarean delivery was performed in 164 (53.2%) obese, 407 (43.1%) pre-obese, 1,045 (35.1%) normal weight and 64 (24.5%) underweight women. The relative risk for cesarean delivery in obese women was 1.8 (95% CI: 1.5-2.0) compared to normal weight women. Greater weight gain was particularly associated with cesarean among the obese (RR 4th vs 2nd weight gain quartile 2.2; 95% CI: 1.4-3.2). Increased weight at the beginning of pregnancy was associated with a significantly higher adjusted risk of meconium with vaginal delivery and perinatal death and infection in women submitted to cesarean section. Similarly, greater weight gain during pregnancy increased the risk for meconium and hemorrhage in women submitted to vaginal delivery and for prematurity with cesarean. CONCLUSIONS: Pre-gestational obesity and greater weight gain independently increase the risk of cesarean delivery, as well as of several adverse outcomes with vaginal delivery. These findings provide further evidence of the negative effects of prepregnancy obesity and greater gestational weight gain on pregnancy outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to estimate the prevalence of herpes simplex virus type 2 (HSV 2) antibodies in child bearing women of 2 Brazilian populations with different socioeconomic status and to determine the risk of neonatal HSV exposure by means of maternal cultures at the onset of labor. The study was conducted at 2 hospitals: A, serving very low income patients and B, serving middle socioeconomic class. 173 participants from group A and 127 from B answered a questionnaire which showed that the patients had similar ages (27.7 and 26.8 years, respectively) but differed with regard to socioeconomic status, age at first intercourse (18.6 vs 20.6 years), number of sex partners (1.5 vs 1.2) and previous sexually transmitted diseases (15% vs. 1.5%). History of genital herpes was given by 11% of group A participants and by a similar number, 7%, of patients from group B. In addition, 200 serum samples from population A and 455 from B were tested by ELISA for and HSV antibodies and 92% and 86%, respectively, were found to be positive. Sixty seropositive samples from group A and 90 from B were further analyzed by Western blot, which showed the presence of type 2 specific antibodies in 46% and 36%, respectively, suggesting an overall HSV 2 prevalence of 42% in group A and 31% in B. Cervical specimens were obtained for culture from 299 asymptomatic patients of population A and 313 of B. HSV was isolated from one specimen in each group, indicating a 0.3% incidence of asymptomatic viral excretion in both populations. In conclusion, the prevalence of type 2 antibodies in childbearing women was very high, but it did not differ with the socioeconomic status. The risk of HSV perinatal transmission was also similar in the 2 study populations and it was comparable with the data from developed countries. Our findings do not indicate the need of special screening programs for asymptomatic HSV excretion in Brazilian pregnant women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leishmaniasis is one of the six major tropical diseases targeted by the World Health Organization. It is a life-threatening disease of medical, social and economic importance in endemic areas. No vaccine is yet available for human use, and chemotherapy presents several problems. Pentavalent antimonials have been the drugs of choice to treat the disease for more than six decades; however, they exhibit high toxicity and are not indicated for children, for pregnant or breastfeeding women or for chronically ill patients. Amphotericin B (AmpB) is a second-line drug, and although it has been increasingly used to treat visceral leishmaniasis (VL), its clinical use has been hampered due to its high toxicity. This review focuses on the development and in vivo usage of new delivery systems for AmpB that aim to decrease its toxicity without altering its therapeutic efficacy. These new formulations, when adjusted with regard to their production costs, may be considered new drug delivery systems that promise to improve the treatment of leishmaniasis, by reducing the side effects and the number of doses while permitting a satisfactory cost-benefit ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device embolized to the distal pulmonary bed and, after being rescued with a Bitome, it was appropriately repositioned with no complications and with total occlusion of the vessel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved device for detecting peridomestic Triatoma infestans consisting of one-liter recycled Tetra Brik milk boxes with a central structure was tested using a matched-pair study design in two rural areas in Argentina. In Olta (La Rioja), the boxes were installed beneath the thatched roofs and on the vertical wooden posts of each peridomestic structure. After a 5-month exposure, at least one of the recovered boxes detected 88% of the 24 T. infestans-positive sites, and 86% of the 7 negative sites by timed manual collections at baseline. In Amamá (Santiago del Estero), the boxes were paired with the best performing prototype tested before (shelter unit). After 3 months, some evidence of infestation was detected in 89% (boxes) and 79% (shelters) of 18-19 sites positive by timed collections, whereas 19% and 16% of 32 negative sites were positive, respectively. Neither device differed significantly in the qualitative or quantitative collection of every sign of infestation. The installation site did not modify significantly the boxes' sampling efficiency in both study areas. As the total cost of each box was half as expensive as each shelter unit, the boxes are thus the most cost-effective and easy-to-use tool for detecting peridomestic T. infestans currently available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is still imperative to develop a parasitological technique highly sensitive for diagnosing schistosomiasis in epidemiological and individual surveys. A simple and cheap hatching device with a collecting container was manufactured and tested under experimental conditions. Twelve Kato-Katz slides were performed as golden standard for comparison. Quantitative results can be carried out by counting miracidia in a plate and parasite load can be calculated (miracidia/gram of feces). Statistically significant values were higher in the hatching test. More sensitive results, with statistical significance, were achieved using 1.5 g of feces (which corresponds to 36 Kato-Katz slides) than by using the Kato-Katz method. Advantages of this technique and its limitations are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the feasibility of using halloysite clay nanotubes (HNTs) and carboxyl-functionalised multi-walled carbon nanotubes (COOH-MWCNTs) as antigen carriers to improve immune responses against a recombinant LipL32 protein (rLipL32). Immunisation using the HNTs or COOH-MWCNTs significantly increased the rLipL32-specific IgG antibody titres (p < 0.05) of Golden Syrian hamsters. None of the vaccines tested conferred protection against a challenge using a virulent Leptospira interrogans strain. These results demonstrated that nanotubes can be used as antigen carriers for delivery in hosts and the induction of a humoral immune response against purified leptospiral antigens used in subunit vaccine preparations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractOBJECTIVEPresenting methodology for transferring knowledge to improve maternal outcomes in natural delivery based on scientific evidence.METHOD: An intervention study conducted in the maternity hospital of Itapecerica da Serra, SP, with 50 puerperal women and 102 medical records from July to November 2014. The PACES tool from Joanna Briggs Institute, consisting of pre-clinical audit (phase 1), implementation of best practice (phase 2) and Follow-up Clinical Audit (phase 3) was used. Data were analyzed by comparing results of phases 1 and 3 with Fisher's exact test and a significance level of 5%.RESULTSThe vertical position was adopted by the majority of puerperal women with statistical difference between phases 1 and 3. A significant increase in bathing/showering, walking and massages for pain relief was found from the medical records. No statistical difference was found in other practices and outcomes. Barriers and difficulties in the implementation of evidence-based practices have been identified. Variables were refined, techniques and data collection instruments were verified, and an intervention proposal was made.CONCLUSIONThe study found possibilities for implementing a methodology of practices based on scientific evidence for assistance in natural delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.