222 resultados para Total polyphenols
Resumo:
Total spectrofluorimetry associated to Principal Components Analysis (PCA) were used to classify into different groups the samples of diesel oil, biodiesel, vegetal oil and residual oil, as well as, to identify addition of non-transesterified residual vegetable oil, instead of biodiesel, to the diesel oil. Using this method, the samples of diesel oil, mixtures of biodiesel in diesel and mixtures of residual oil in diesel were separated into well-defined groups.
Resumo:
The purpose of the present study was to validate a method for organic Hg determination in sediment. The procedure for organic Hg was adapted from literature, where the organomercurial compounds were extracted with dichloromethane in acid medium and subsequent destruction of organic compounds by bromine chloride. Total Hg was performed according to 3051A USEPA methodology. Mercury quantification for both methodologies was then performed by CVAAS. Methodology validation was verified by analyzing certified reference materials for total Hg and methylmercury. The uncertainties for both methodologies were calculated. The quantification limit of 3.3 µg kg-1 was found for organic Hg by CVAAS.
Resumo:
A method based on enzymatic activities was developed using three enzymes (glycerokinase, glycerol-3-phosphate oxidase and peroxidase) and colorimetric detection for the determination of glycerol in biodiesel. The enzymatic conversion of glycerol produces H2O2 that is eliminated by the action of peroxidase, an oxygen acceptor and 4- aminoantipirine, producing water and a colored compound, which was analyzed. This method showed good linear correlation coefficient (r = 0.9937) in the concentration range of 4.95 x 10-5 to 3.96 x 10-4% (w/w) and had experimental limits of detection and quantitation of 7.10 x 10-6 and 2.10 x 10-5% (w/w), respectively.
Resumo:
A sequential extraction procedure was applied to wheat and soybean seed samples. The total protein content (determined by two distinct methods: Bradford and bicinchoninic acid-BCA) and distribution of Cu, Fe, Mn and Zn in each fraction was determined. The sequential extraction employed four different solutions: water, 0.5 mol L-1 NaCl, ethanol/water (70:30 v v-1) and 0.5 mol L-1 NaOH. For both samples, the highest concentration of metals was observed in those extracts associated with globulin-type proteins using NaCl solution. Regarding protein content, higher levels were obtained using the BCA method.
Resumo:
Hydrogen peroxide has been used for decades in developed countries as an oxidizing agent in the treatment of water, domestic sewage and industrial effluents. This study evaluated the influence of the concentration of H2O2 and pH on the inactivation of Escherichia coli cells and the disinfection of sewage treated. The results showed that the inactivation rate increased with pH and H2O2. The presence of other contaminants dissolved in the effluent is probably the cause of these differences, because E. coli inactivation in synthetic wastewater was found to be much faster than in the real treated domestic sewage.
Resumo:
An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).
Resumo:
The oxidation of sulphur compounds upon burning emits large quantities of SOx into the atmosphere. Therefore, there is growing interest in fast and accurate methods for analyzing sulphur content in fuels. The objective of this work was to compare four different methods of total sulphur determination in solid fuels. The methods used in this work were Eschka, Infrared, Thermal Conductivity Detection (TCD) and Ultraviolet Fluorescence Detection (UV). The preliminary results showed that TCD and UV methods (nonstandard methods for solid fuels) have similar precision to the infrared method (standard method) for high-sulphur coal samples.
Resumo:
We propose an analytical method based on fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy to detect the adulteration of petrodiesel and petrodiesel/palm biodiesel blends with African crude palm oil. The infrared spectral fingerprints from the sample analysis were used to perform principal components analysis (PCA) and to construct a prediction model using partial least squares (PLS) regression. The PCA results separated the samples into three groups, allowing identification of those subjected to adulteration with palm oil. The obtained model shows a good predictive capacity for determining the concentration of palm oil in petrodiesel/biodiesel blends. Advantages of the proposed method include cost-effectiveness and speed; it is also environmentally friendly.
Resumo:
In this study, hierarchical cluster analysis (HCA) and principal component analysis (PCA) were used to classify blends produced from diesel S500 and different kinds of biodiesel produced by the TDSP methodology. The different kinds of biodiesel studied in this work were produced from three raw materials: soybean oil, waste cooking oil and hydrogenated vegetable oil. Methylic and ethylic routes were employed for the production of biodiesel. HCA and PCA were performed on the data from attenuated total reflectance Fourier transform infrared spectroscopy, showing the separation of the blends into groups according to biodiesel content present in the blends and to the kind of biodiesel used to form the mixtures.
Resumo:
The synthesis of 3-coumarin-carboxylic acids and their application to the total synthesis of the natural products ayapin, coumarin, and umbeliferone in undergraduate organic chemistry experiments is described herein. The synthetic approach consists of a one-pot cyclization between salyciladehydes and Meldrum's acid in water to produce the above mentioned acids, followed by decarboxylation under basic or radical conditions.
Resumo:
The determination of the total calcium in juice, syrups, and other products of the sugar industry is investigated. Total calcium and free calcium is determinated by AAS and employing Ca-selective electrode respectively. A coefficient is obtained for the relation of total calcium with respect to free calcium. The coefficient is employed to determine the content of total calcium in accordance with the following equation.
Resumo:
A introdução do assunto qualidade, segundo as necessidades de mercado abre espaço para a discussão da qualidade como necessidade pessoal, e também para a formação do cidadão/profissional, além de introduzir assuntos específicos de administração de empresas. Dessa forma, foi oferecida uma disciplina optativa para os alunos do Instituto de Química do Campus de Araraquara, abordando o tema Qualidade e foi denominada "Gestão da Qualidade" por três anos seguidos. Da avaliação geral do curso extraiu-se que ele deveria ser realizado sempre, que o tema é atual e relevante e contribui para a formação profissional/pessoal. Com relação ao comprometimento com o curso de graduação, cerca de metade dos alunos assume o seu comprometimento com os estudos e os restantes dizem estarem somente envolvidos. Conclui-se, portanto que o curso atingiu os seus objetivos propostos, introduziu os principais conceitos de qualidade segundo as normas da qualidade da série ISO 9000 e suscitou a discussão da formação do aluno/profissional/cidadão.
Resumo:
Observando a literatura pode ser verificado um crescente número de trabalhos que determinam potenciais contaminantes presentes em matrizes de interesse ambiental. É importante ressaltar que quando se estuda o ambiente, os dados analíticos são uma das ferramentas usadas para se avaliar a extensão dos problemas observados que conseqüentemente influenciam as tomadas de decisão. Assim a confiabilidade desses dados é de extrema importância. Neste contexto, este trabalho visa avaliar a confiabilidade analítica das determinações de Carbono Orgânico Total (COT), ferramenta empregada no monitoramento da matéria orgânica em diversos estudos ambientais. Para essa avaliação foram analisados alguns parâmetros de desempenho como limite de detecção e quantificação, repetibilidade e linearidade.
Resumo:
No presente trabalho os parâmetros de desempenho (validação intralaboratorial) da metodologia de determinação de TPH (Total Petroleum Hydrocarbons) foram determinados por detecção na região do infravermelho com o equipamento da Infracal TOG/TPH, visando aplicação em amostras de areia contaminadas com petróleo. Os ensaios foram realizados utilizando Óleo Marine Fuel 380, com densidade igual 0,987 g cm-3 e viscosidade de 5313 cP a 20°C. Este óleo foi fornecido pelo Centro de Pesquisa da Petrobrás (CENPES/PETROBRÁS/RJ), sendo o mesmo óleo derramado no acidente ocorrido em janeiro de 2000, na Baia de Guanabara, RJ, quando 1.300 m3 vazaram do duto que interliga a REDUC (Refinaria Duque de Caxias, RJ) ao terminal da Ilha dÁgua/RJ, atingindo praias. Os resultados da validação indicaram que o desempenho da metodologia foi favorável à aplicação que se destina. Entre os parâmetros metrológicos obtidos neste trabalho, o limite de detecção do método foi de 4,06 mg L-1, consideravelmente inferior à faixa de concentração normalmente obtida para amostras em tais situações.
Resumo:
Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of total sulfur in the form of sulfate, precipitated in the form of barium sulfate, is presented. The method was applied to biodiesel, to plant leaves and to natural waters analysis. The analytical signal (S) correlates linearly with sulfate concentration (C) between 20 and 120 ppm, through the equation S=-1.138+0.0934 C (r = 0.9993). The experimentally observed limit of detection is about 10 ppm. The mean R.S.D. is about 3.0 %. Real samples containing sulfate were analyzed and the results obtained by the FI and by the reference batch turbidimetric method using the statistical Student's t-test and F-test were compared.