256 resultados para Gc-eag


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The combination of high performance exclusion chromatography (HPEC) and gas chromatography (GC) was applied to the analysis of six coffee samples that were previously characterized by sensory tests as of good or poor quality. The data obtained by the two techniques were statistically evaluated by "Principal Components Analysis" (PCA) using selected peak areas. The results showed the potential of the described techniques for coffee analysis. The HPEC technique monitored with the U.V. detector at 272 nm and followed by PCA may be correlated with sensorial data, particularly if a wider group of samples is used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a chromatographic method to fractionate volatile oils and to identify their sesquiterpenic constituents. The fractionation process includes flash chromatography over silica gel and chromatography over silica gel/AgNO3, utilising pentane, CH2Cl2 and/or acetone as eluents. GC chromatograms were obtained in order to get the relative percentage of each constituent in the volatile oils, to get the retention time value of them as well as to analyse and combine the fractions eluted from the columns. Such procedure afford mixtures of sesquiterpenes which are analysed by GC/MS, 13C and ¹H NMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid-phase microextraction (SPME) has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs), linearity and precision. The detection limits (S/N = 3) depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A selection of common procedures which are used for the identification and analysis of volatile biologically active compounds from insects are described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Herein we describe the isolation of homarine and piridiniumbetaine B from the sponge Aaptos sp. Although homarine has a common occurrence among animals, piridiniumbetaine B was only recently isolated from the marine sponge Agelas dispar. The isolation of piridiniumbetaine B from two taxonomically distant marine sponges corroborate previous assumptions that such betaines should be regarded rather as primary metabolites. We have also isolated (9-[5'-(methylthio)-beta-D-xylofuranosyl]adenine (xylosyl-MTA) from the mantle of a nudibranch identified as Doris aff. verrucosa. The occurrence of xylosyl-MTA in the mantle of this animal strongly suggests that it is the same nudibranch species described for the Mediterranean sea. We have been unable to detect any other compound in the mantle extract of D. aff. verrucosa other than xylosil-MTA and sterols. GC-MS analysis of the sterol fraction from the nudibranch and its prey, the sponge Hymeniacidon aff. heliophila, revealed the occurrence of the ubiquitous sterols, cholesterol, brassicasterol, cholestanol, 24-methylcholesterol and 24-ethylcholesterol, as the only common metabolites, therefore precluding any assumption concerning the sequestration of secondary metabolites by the nudibranch from H. aff. heliophila.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A critical evaluation is presented on the use of faecal sterols for the identification of sewage contamination in Guanabara Bay. Sediments were collected from 8 stations in the bay selected as representative of different contamination levels. GC/MS determination of faecal sterols gave: coprostanol, 335 - 40000 ng g-1; coprostanone, 112-4136 ng g-1; cholesterol, 1407-7800 ng g-1; cholestanol, 2011 - 10900 ng g-1 and cholestanone, 655-7954 ng g-1. The observed concentration is in accordance with the presence of known pollution sources, however, concentration ratios of different sterols species produced unclear results evidently influenced by primary production and microbial processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gustavia augusta is used in the folk medicine against leishmaniosis and showed anti-inflammatory action. The phytochemical studies of the plant stem bark have led to the isolation of (22E)-stigmasta-7,22-dien-3beta-ol, 24alpha(S)-ethyl-5alpha-colesta-7,trans-22-dien-3-one, D-friedoolean-14-en-3beta-ol, D-friedoolean-14-en-3-one and D-friedoolean-14-en-3alpha-ol along with stigmasterol, alpha-amyrin, beta-amyrin, lupeol, 3alpha-hidroxi-lupeol and betulinic acid. The structures of these compounds were identified by IR, GC/MS, ¹H and 13C NMR spectral analysis and comparison with literature data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of this work was the qualitative study of organic compounds in landfill leachate. The samples were collected from a sanitary landfill located at Gravataí, a southern Brazilian city, that receive both, industrial and domestic refuse. The samples were submitted to solid phase extraction (SPE) with XAD-4 resin as the stationary phase. The instrumental analysis was performed by Gas Chromatography with a Mass Spectrometry Detector (GC/MSD). The compounds achieved in the SPE extracts were tentatively identified by the GC/MS library. It was found several oxygen and nitrogen compounds like carboxylic acids, ketones, amines and amides. Sulfur compounds and phthalate esters are also identified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fractionation column with SiO2 of the hexane extract of Sebastiania argutidens (Euphorbiaceae) yielded fractions containing hydrocarbons, carboxylic acids, sterols and pentacyclic triterpenes. Besides, one fraction showed the presence of several methyl esters, including four uncommon long chain palmitate esthers as minor components. The characterization of these chemical constituents have been done by High Resolution Gas Chromatography (HRGC) and HRGC coupled to Mass Spectrometry (GC/MS). Campesterol, stigmasterol, b-sitosterol, glutin-5-en-3-ol were identified by HRGC co-injection with standards.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Isotopic and elemental analysis of N, C and S in liquid and solid samples has been simplified with the advent of automated systems. The simplest method of automation for this kind of analysis involves an elemental analyzer interfaced directly to the ion source of an IRMS (Isotope Ratio Mass Spectrometry). In the analyzer reduction system, an expressive amount of oxidized copper is generated as solid residue. This material is normally imported and the price is very high. A methodology was proposed for the recovery of metallic copper in order to recycle this reagent in the reduction system of a GC-IRMS, using the hydrogen gas in the vacuum line. Results show that it is possible to obtain a recycle of about 95 % of the initial metallic copper used in the reduction system.