130 resultados para capillary liquid chromatography
Resumo:
The first two papers in this series described the basic theory involved in supercritical fluid chromatography (SFC), how the technique evolved from gas and liquid chromatography and how the instrumentation was developed. Over the last two years, a commercial, dedicated packed-column SFC/MS instrument appeared on the market. The SFC continues to grow in use, with fundamental developments, coupled with a steady rise in the number of industrial users and applications.
Resumo:
There is great interest nowadays in the use of preparative liquid chromatography as an effective tool for the production of enantiomerically pure, or enriched, compounds for the pharmaceutical industry. To make the chromatographic process economically attractive, attention is now focused on the choice of the chromatographic operating mode to minimize eluent consumption and to maximize productivity. Among the alternatives to the traditional batch chromatography, attention is now shifting towards simulated moving bed (SMB) technologies and a review covering the latest developments in this area seems timely. Several aspects of this important analytical technique are presented and details concerning the SMB technology for process optimization are outlined.
Resumo:
A high performance liquid chromatography method was developed to quantify lamivudine, stavudine and nevirapine combined in tablets. The separation was carried out in less than 10 min using a phosphate buffer of pH 3.0 and acetonitrile (75:25, v/v) as mobile phase, a LiChrospher ODS column and UV detection at 266 nm. The method was linear over the range of 15-135 µg/mL (lamivudine), 4-36 µg/mL (stavudine) and 20-180 µg/mL (nevirapine). The accuracy ranged from 98.56 to 102.04% and intra-day and inter-day precision was less than 1% for the three drugs. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.
Resumo:
A reverse phase liquid chromatography method was developed for simultaneous determination of trigonelline, caffeine, nicotinic and chlorogenic (5-CQA) acids in roasted coffee. A gradient of acetic acid/acetonitrile was used as mobile phase and detection was carried out in the UV. The samples were extracted with acetonitrile/water (5:95 v/v) at 80 ºC/10 min. Good recovery (89 to 104%), repeatability and linearity were obtained. Detection limits of 0.01, 0.15, 0.04 and 0.04 mg mL-1 were observed for nicotinic acid, trigonelline, 5-CQA and caffeine. The method, applied to arabica and robusta coffees with different degrees of roasting, was efficient and fast (~35 min) and also allowed identification of cinnamic acids.
Resumo:
Paclobutrazol is a plant growth retardant which is used world-wide for increasing the yield of cereal crops. However, this compound remains active in the soil for several years and can severely affect the growth and development of subsequent crops, mainly by reducing vegetative vigor. The aim of this work was to develop and validate methods for the determination of paclobutrazol concentrations by both high performance liquid chromatography and spectroscopy. Both methods were satisfactory and showed appropriately low quantification limits. The determination by spectroscopy has, however, the advantage of being a method significantly less expensive than high performance liquid chromatography.
Resumo:
Itraconazole is a synthetic antifungal drug administered orally with a broad spectrum of activity against mycotic infections. The present work consists of the development and validation of analytical methodology for evaluation of itraconazole in pharmaceutical products by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/diethylamine 0.05% v/v, 60:40 v/v, pH 8.0 as mobile phase, methanol as solvent and detection and quantification at 254 nm. The results here obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 8.0-12.0 µg/mL of itraconazole. The method was applied to pharmaceutical capsules containg itraconazole pellets and showed to be efficient, yielding good results.
Resumo:
The analytical method of high performance liquid chromatography (HPLC) for the assay of benznidazole in tablets was developed and validated following the requirements of regulatory agencies. The method used as mobile phase acetonitrile:wather 1:1, a C18 column of 12.5 cm length x 4 mm id, 5 mm particles and lambda=316 nm. The statistical analysis of the results demonstrated that the method satisfies all parameters so as to be considered a safe and efficient analytical alternative of low cost for laboratory routine.
Resumo:
The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.
Resumo:
Gas chromatography (GC) with trimethylsilyl derivative formation was compared to high-performance liquid chromatography (HPLC) for quantification of organic acids (OAs) in two jaboticaba (Myrciaria) fruit (pulp and pericarp) varieties (Sabará and Açu Paulista). Succinic and citric acids were the major OAs found in all the samples analyzed. Besides being much more tedious, the results obtained with GC were significantly lower than HPLC (p<0.05) when the data (acids, variety, two parts and flowering days) were considered together. The presence of both acids was confirmed by gas chromatography-mass spectrometry (GC-MS).
Resumo:
In this work the exposure of wells and surface water to pesticides, commonly used for tobacco cropping, was assessed. Water consumption wells and surface water flows were sampled at different times. After a preconcentration step with solid phase extraction (SPE), the selected pesticides were determined by gas chromatography with electron capture detection (GC-ECD) or high performance liquid chromatography with diode array detection (HPLC-DAD). No pesticides were detected in the well water samples and surface water flow in the winter season. However, in the spring and summer higher concentrations of chlorpyrifos and imidacloprid were found in the water source samples. Atrazine, simazine and clomazone were also found. The occurrence of pesticides in collected water samples was related with the application to tobacco.
Resumo:
The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.
Resumo:
Nine flavonoids were identified in aerial parts of Astragalus corniculatus Bieb. (Fabaceae) by liquid chromatography coupled with ionspray mass spectrometry in the tandem mode (LC/MS/MS) with negative ion detection. Vitexin, orientin and eriodictyol-7-O-glucoside are obtained for the first time in genus Astragalus L, and isorhamnetin-3-O-glucoside in the species.
Resumo:
This paper presents a simple and practical thermogravimetric method for determining the layer thickness of immobilized polymer stationary phases used in reversed-phase high-performance liquid chromatography. In this method, the weight loss of different polysiloxanes immobilized onto chromatographic supports, determined over the temperature range 150-650 ºC, demonstrated excellent agreement with the sum of carbon and hydrogen content obtained by elemental analysis. The results presented here suggest that the thermogravimetric procedure is an accurate and precise method to determine the polymeric material content on polymer-coated stationary phases.
Resumo:
The purpose of this work was to determine the safe shelf life of single-base propellants. The kinetic parameters relative to the consumption of the stabilizer diphenylamine (DPA) added to the propellant were determined as a function of the storage and ageing time. High Performance Liquid Chromatography (HPLC) with spectrophotometric detection was used to determine the DPA percentage before and after the artificial ageing at 60, 70 and 80 ºC. The experimental data were very well adjusted to a pseudo-first order kinetic model and the respective kinetic constants are 8.0-10-3 day-1 (60 ºC); 1.9-10-2 day-1 (70 ºC); 1.2-10-1 day-1 (80 ºC). The activation energy was calculated as 130 kJ mol-1 and the half-time for depletion of the DPA at the hypothetical temperature of 40 ºC of storage was estimated as being 6 years.
Resumo:
A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.