212 resultados para Sodium acetate buffer pH 4.0


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A technique for both extraction and activity measurement of peroxidase extracted from arazá (Eugenia stipitata Mc Vaugh) is described. Peroxidase from arazá pulp fruit was extracted using a combination of protein precipitation with acetone and extraction with 50 mM sodium buffer phosphate (pH 6.0). Optimum activity using guaiacol as H-donor was obtained at pH from 5.0 to 6.5, temperature from 60 to 75 °C, H2O2 between 10 to 15 mM and guaiacol from 80 to 160 mM. Thermal inactivation showed a first-order inactivation kinetic. Reactivation was observed when extracts were heated at 80 °C and afterwards incubated at 25 °C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the validation of a method for quantification of famotidine in capsules by UV spectrophotometry using as solvents buffer solution at pH 2.5 and buffer solution at pH 4.5. The results show that the method is practical, selective, accurate, precise and linear from 10.0 to 25.0 µg/mL of famotidine in both solvents. However, a variance analysis showed a lower mean percentage of famotidine when buffer at pH 2.5 is used. This effect was attributed to the instability of famotidine in acidic media. Therefore, the use of pH 4.5 buffer was considered suitable for analysis of famotidine in capsules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study proposes a method for cloud point preconcentration of copper ions at pH 2.0 based on complexes formed with [4,5-dimercapto-1,3-dithyol-2-thionate] and subsequent determination by flame atomic absorption spectrometry (FAAS). Under optimal analytical conditions, the method provided limits of detection of 0.84 and 0.45 µg L-1, by preconcentrating 12.0 and 24.0 mL of sample, respectively. The method was applied for copper determination in water samples, synthetic saliva, guarana powder, tea samples and soft drinks and the accuracy was assessed by analyzing the certified reference materials Dogfish Liver (DOLT-4) and Lobster Hepatopancreas (TORT-2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bactéria fitopatogênica Xanthomonas campestris pv. viticola (Xcv) causa o cancro bacteriano da videira (Vitis vinifera), que ocasiona grandes prejuízos à viticultura no Brasil. Os métodos de dessecação em papel de filtro (DPF), repicagens periódicas (RP), água destilada esterilizada (ADE) e folhas herborizadas (FH) foram utilizados para preservar duas estirpes de Xcv durante 12 meses. As variáveis viabilidade e patogenicidade foram avaliadas mensalmente e estimadas pela obtenção de crescimento bacteriano e área abaixo da curva de incidência da doença (AACID). Tanto o método de DPF como o de ADE propiciaram viabilidade constante de 100% durante 11 meses e os maiores valores de AACID. No método de RP não houve crescimento das estirpes já aos 30 dias, enquanto que, em FH, Xcv foi isolada até cinco meses. o crescimento das estirpes de Xcv em meio de cultura líquido variando temperatura (0, 5, 10, 15, 20, 25, 27, 28, 29, 30, 35, 40 e 45 °C), pH (5,0; 5,5; 6,0; 6,5; 7,0; 7,5; 8,0; 8,5 e 9,0) e concentração de NaCl (1, 2, 3, 4, 5, 6 e 7%) foi avaliado em fotocolorímetro. O crescimento de Xcv foi observado no intervalo de 5 até 35 °C, enquanto que o crescimento ótimo ocorreu de 27 a 29 °C. A Xcv não cresceu a zero e 40 °C. O pH ótimo para o crescimento desta bactéria foi 7,5. O crescimento de Xcv decresceu a partir de 3,0% de NaCl, com concentração letal de 6,0%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The stoichiometry of the polyanions formed by the action of nitric acid on sodium tungstate (< 0.01M) has been studied by means of electrometric techniques involving pH-potentiometric and conductometric titrations. The well defined inflections and breaks in the titration curves provide evidence for the existence of the polyanions, para-W12O41(10-) and meta-W12O39(6-) corresponding to the ratio of H+:WO4(2-) as 7:6 and 9:6 in the pH ranges 5.7-6.0 and 3.6-4.1, respectively. The interaction of lanthanum nitrate with sodium tungstate solutions, at specific pH levels 8.0, 5.9 and 4.0 was also studied by pH and conductometric titrations, in aqueous and alcoholic media, with each of the reagents alternatively used as titrant. The electrometric experiments provide definite evidence of the formation of normal-La2O3.3WO3, para-5La2O3.36WO3 and meta-La2O3.12WO3 tungstates in the vicinity of pH 6.3, 5.0 and 4.2, respectively. Analytical investigations on the precipitates formed confirm the results of the electrometric study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple spectrophotometric method for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin with variamine blue is presented. The determination is based on the hydrolysis of β-lactam ring of cephalosporins with sodium hydroxide which subsequently reacts with iodate to liberate iodine in acidic medium. The liberated iodine oxidizes variamine blue to violet colored species of maximum absorption at 556 nm. The absorbance is measured within the pH range of 4.0-4.2. Beer's law is obeyed in the range of 0.5-5.8 µg mL-1, 0.2-7.0 µg mL-1, 0.2-5.0 µg mL-1 and 0.5-8.5 µg mL-1 for cefotaxime, ceftriaxone, cefadroxil and cephalexin respectively. The analytical parameters were optimized and the method is successfully applied for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin in pharmaceuticals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and rapid spectrophotometric method for the determination of nevirapine is described. The method is based on the reaction of nevirapine with tetrathiocyanatocobalt(II) ion in buffer of pH 4 to form the corresponding complex. Beer's law is obeyed in the range of 0.2 - 2.0 µg mL-1 for nevirapine. The optical parameters such as molar absorptivity, Sandell's sensitivity, detection limit and quantitation limit were found to be 1.16× 10(4) Lmol-1cm-1, 2.09 X 10-3 µg cm-2, 0.073 µg mL-1 and 0.222 µg mL-1 respectively. The optimum reaction conditions and other analytical parameters were evaluated. The statistical evaluation of the method was examined by determining intra-day and inter-day precision. The proposed method has been successfully applied for the determination of nevirapine in pharmaceutical formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o objetivo de determinar a dose e a faixa de pH dos coagulantes sulfato de alumínio (SA), sulfato ferroso clorado (SFC), cloreto férrico (CF) e extrato de semente de moringa (ESM), que proporcionassem maior eficiência na remoção da turbidez na água residuária da despolpa de frutos do cafeeiro (ARDC), após serem efetuadas cinco recirculações, foram conduzidos ensaios de coagulação/floculação utilizando o aparelho "Jar-test". Todos esses coagulantes foram avaliados nas concentrações de 0; 0,5; 1,0; 1,5; 2,0; 2,5 e 3,0 g L-1. No caso da solução preparada com ESM, as doses utilizadas foram: 0; 10; 20; 30; 40; 50 e 60 mL L-1. O pH da solução em teste foi alterado, utilizando-se do hidróxido de sódio (NaOH), na concentração de 0,3 mol L-1, sendo avaliadas as faixas de 4,0 a 5,0; 5,0 a 6,0; 6,0 a 7,0 e 7,0 a 8,0. No ensaio de coagulação/floculação, o ESM proporcionou maior remoção de SS (sólidos em suspensão) da ARDC com a dose de 10 mL L-1 e pH de 4,27 (natural). Para os coagulantes SA e CF, os melhores resultados foram obtidos com a concentração de 3 g L-1 e pH de 7,27 e, para o coagulante SFC, com a concentração de 3 g L-1 e pH de 4,27.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visando estudar a tolerância do picão-preto (Bidens pilosa) a diferentes níveis de pH do substrato, conduziu-se um ensaio em condições de câmara de crescimento e utilizando-se a técnica de hidroponia, no qual três plântulas foram transplantadas para recipientes contendo solução nutritiva de Hoagland & Arnon, com pH ajustado para 3,5, 4,0, 5,0, 6,0, 7,0 e 8,0. O delineamento experimental utilizado foi o inteiramente casualizado com três repetições. Ao final do período experimental, 42 dias após o transplante, observou-se que as plantas que se desenvolveram nos pHs 3,5 e 8,0 apresentaram-se menores, com menor comprimento e volume do sistema radicular, menor número de folhas vivas e, consequentemente, menor peso de matéria seca das folhas, caule e raízes. Os teores de N e S nas raízes diminuiram com o aumento do pH do substrato, enquanto os de Ca e Mg aumentaram e os de K e P diminuiram no pH 5,0 a 6,0. No caule, apenas o teor de Mg foi afetado pelo pH, mostrando resposta positiva. Na folha obteve-se os maiores teores de P, S, Ca e Mg quando a planta se desenvolveu em pH 6,0. Não se constatou diferença significativa entre os efeitos dos pHs 5,0, 6,0 e 7,0 nos parâmetros avaliados, sendo que foi no pH 6,0 que se estimou, através de análise de regressão, melhor desenvolvimento do picão-preto. Concluiu-se que o picãopreto apresenta melhor desenvolvimento em pHs próximo ao neutro, com certa tolerância a pHs extremos (3,5 e 8,0).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O estudo objetivou avaliar os coeficientes adsortivos e dessortivos de ametryn e trifloxysulfuron-sodium em seis solos brasileiros, com intuito de prever o comportamento e o potencial de movimentação desses herbicidas nos solos. Utilizou-se o método Batch slurry, conduzido em condições controladas de laboratório. Para isso, 10,0 mL das soluções em CaCl2 0,01 mol L-1, contendo 0, 5, 10, 25, 50 e 100 µg mL-1 de ametryn e 0; 0,25; 0,5; 1,0; 2,0; e 4,0 µg mL-1 de trifloxysulfuron-sodium, foram adicionadas em frascos com 2,0 g de solo, permanecendo sob agitação orbital até atingir o tempo de equilíbrio. Após centrifugação e filtração, a concentração do sobrenadante foi determinada por cromatografia líquida de alta eficiência (CLAE), com detector UV a 245 nm. A dessorção foi avaliada para a maior dosagem utilizada de cada composto. O solo Latossolo Vermelho distroférrico - LVdf (Sete Lagoas) apresentou o maior coeficiente de adsorção (Kf) para ambos os herbicidas, sendo o mesmo atribuído ao seu elevado teor de matéria orgânica (MO). Verificou-se correlação positiva do Kf de ametryn com MO (0,81), percentual de argila (ARG) (0,80) e capacidade de troca catiônica (CTC) (0,75) dos solos, sendo a MO identificada como o principal contribuinte na sua adsorção. Entretanto, o Kf de trifloxysulfuron-sodium apresentou apenas pequena correlação com ARG (0,48) e MO (0,28), sendo sua adsorção dependente, possivelmente, do teor de óxidos de Fe e Al presentes no solo. Baixos índices H de histerese foram verificados no ametryn em relação a trifloxysulfuron-sodium, representando maior potencial de dessorção e, conseqüentemente, risco de lixiviação desse herbicida no perfil dos solos estudados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivou-se com este trabalho determinar a meia-vida (t½) do herbicida ametryn em Argissolo Vermelho-Amarelo e Latossolo Vermelho-Amarelo, com diferentes valores de pH. Foram utilizados vasos revestidos internamente com filme plástico e preenchidos com 330,0 g de amostras dos solos em estudo (Latossolo Vermelho-Amarelo - LVA com valores de pH corrigidos para 4,4, 4,9 e 5,8, e Argissolo Vermelho-Amarelo - PVA com pH 5,9). As amostras desses solos foram coletadas em pastagens degradadas isentas da aplicação de herbicidas. A essas amostras foi aplicado o ametryn na dose de 2,5 L ha-1. Doze horas após essa aplicação, foram retiradas as primeiras amostras de solo dos vasos, para determinação da concentração no tempo zero, e a cada cinco dias foram retiradas novas amostras de outros vasos, visando à determinação da concentração de ametryn ao longo do tempo. A extração do ametryn da matriz solo foi realizada por Extração Sólido Líquido com Partição em Baixa Temperatura (ESL-PBT), e o herbicida, quantificado por cromatografia líquida de alta eficiência - CLAE. Foi realizado, em paralelo, um teste biológico para determinação indireta da persistência do herbicida. A análise dos dados indicou que a meia-vida (t½) do ametryn nos solos avaliados foi de 26, 19, 12 e 11 dias para os solos LVA pH 4,4; LVA pH 4,9; LVA pH 5,8; e PVA pH 5,9, respectivamente. Ambos os métodos (cromatografia ou bioensaios) utilizados para avaliação da persistência do ametryn nos solos evidenciaram que a degradação desse herbicida é muito influenciada pelo pH do solo e pelo teor de matéria orgânica.