128 resultados para line efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate a generalized response function to the atmospheric CO2 concentration [f(CO2)] by the radiation use efficiency (RUE) in rice. Experimental data on RUE at different CO2 concentrations were collected from rice trials performed in several locations around the world. RUE data were then normalized, so that all RUE at current CO2 concentration were equal to 1. The response function was obtained by fitting normalized RUE versus CO2 concentration to a Morgan-Mercer-Flodin (MMF) function, and by using Marquardt's method to estimate the model coefficients. Goodness of fit was measured by the standard deviation of the estimated coefficients, the coefficient of determination (R²), and the root mean square error (RMSE). The f(CO2) describes a nonlinear sigmoidal response of RUE in rice, in function of the atmospheric CO2 concentration, which has an ecophysiological background, and, therefore, renders a robust function that can be easily coupled to rice simulation models, besides covering the range of CO2 emissions for the next generation of climate scenarios for the 21st century.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to determine the maintenance requirement and the deposition efficiency of lysine in growing pigs. It was used the incomplete changeover experimental design, with replicates over time. Twelve castrated pigs with average body weight (BW) of 52±2 kg were kept in metabolism crates with a controlled temperature of 22ºC. The diets were formulated to supply 30, 50, 60, and 70% of the expected requirements of standardized lysine, and provided at 2.6 times the energy requirements for maintenance. The trial lasted 24 days and was divided into two periods of 12 days: seven days for animal adaptation to the diet and five days for sample collection. The increasing content of lysine in the diet did not affect dry matter intake of the pigs. The amount of nitrogen excreted was 47% of the nitrogen intake, of which 35% was excreted through feces and 65% through urine. The estimated endogenous losses of lysine were 36.4 mg kg-1 BW0.75. The maintenance requirement of lysine for pigs weighing around 50 kg is 40.4 mg kg-1 BW0.75, and the deposition efficiency of lysine is 90%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to isolate and characterize rhizobia from nodules of Centrolobium paraense and to evaluate their symbiotic efficiency. Soil samples collected from four sites of the Roraima Cerrado, Brazil, were used to cultivate C. paraense in order to obtain nodules. Isolates (178) were obtained from 334 nodules after cultivation on medium 79. Twenty-five isolates belonging to six morphological groups were authenticated using Vigna unguiculata and they were characterized by 16S rRNA. Isolates identified as Bradyrhizobium were further characterized using rpoB gene sequencing. A greenhouse experiment was carried out with C. paraense to test the 18 authenticated isolates. Approximately 90% of the isolates grew slowly in medium 79. The 16S rRNA analysis showed that 14 authenticated isolates belong to the genus Bradyrhizobium, and rpoB indicated they constitute different groups compared to previously described species. Only four of the 11 fast-growing isolates nodulated V. unguiculata, two of which belong to Rhizobium, and two to Pleomorphomonas, which was not previously reported as a nodulating genus. The Bradyrhizobium isolates ERR 326, ERR 399, and ERR 435 had the highest symbiotic efficiency on C. paraense and showed a contribution similar to the nitrogen treatment. Centrolobium paraense is able to nodulate with different rhizobium species, some of which have not yet been described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente pesquisa teve como objetivo estudar os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de campo, no município de São Mateus -- ES, pertencente à maior região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 L de água: chlorothalonil (Daconil PM-200g); mancozeb (Dithane PM -- 200g); oxicloreto de cobre (Reconil -- 400g); thiabendazole (Tecto 450 -- 100ml); dicofol + tetradifon (Carbax -- 200ml); triazophós (Hostathion 400 BR -- 150ml); óxido de fenbutatina (Torque 500 SC -- 60ml); e abamectin (Vertimec 18 CE -- 50ml): Analisou-se a fitotoxicidade dos produtos testados, em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As datas das avaliações foram: 01 dia antes das pulverizações, 15 dias e 30 dias após as mesmas. Os fungicidas Daconil BR, Reconil e Tecto 450; o fungicida acaricida Dithane PM; os acaricidas Carbax e Torque 500 SC; e o inseticida-acaricida Vertimec 18 CE, aplicados isoladamente, não afetaram o crescimento e a produção das plantas, nem causaram injúrias nas folhas das mesmas. A associação de fungicidas e fungicida-acaricida, com os acaricidas, ou inseticida-acaricida, não mostrou nenhum efeito fitotóxico sobre os parâmetros de crescimento avaliados, nem causaram queimaduras ou injúrias foliares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudaram-se os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de verão, no município de São Mateus - ES, localizado na região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela experimental. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 l de água: abamectin (Vertimec 18 CE - 50 ml); dicofol + tetradiphon (Carbax - 200 ml), fenbutatin oxide (Torque 500 SC - 60 ml); mancozeb (Dithane PM - 200g); oxicloreto de cobre (Reconil - 400g) e thiabendazole (Tecto 450 - 100ml). Analisou-se a fitotoxicidade dos produtos em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As medições e contagens foram feitas um dia antes das pulverizações, 15 e 30 dias após. Constatou-se que o Vertimec 18 CE, associado ao Reconil ou ao Tecto 450, ocasionou leves injúrias foliares, detectadas aos 15 dias após as pulverizações, que se tornaram praticamente imperceptíveis, aos 30 dias após as pulverizações; e que Dithane PM, Reconil, Tecto 450, Carbax, Torque 500 SC, Dithane PM + Carbax, Dithane PM + Torque 500 SC, Dithane PM + Vertimec 18 CE, Reconil + Carbax, Reconil + Torque 500 SC, Tecto 450 + Carbax e, Tecto 450 + + Torque 500 SC não interferiram nos parâmetros de desenvolvimento e de produção estudados, bem como não causaram injúrias ou queimaduras nas folhas dos mamoeiros.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity and accuracy of sequential injection methods are dependent on efficient overlapping of reagent and sample zones as they are propelled toward the detector cell. The formation of the reduced phosphomolybdic acid is used to demonstrate that the overlapping efficiency in a fixed reaction coil relies on a suitable choice of reagent to sample volume ratio. Additionally, under poor mixing conditions or highly concentrated samples, the reaction extension is strongly dependent on the reagent concentration. The zone-sampling concept is exploited to determine phosphate in cola-based soft drinks after in-line dilution in an auxiliary coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and characterization of bioreactors or IMER (immobilized enzyme reactors) as research tools are important in the scope of medicinal chemistry and constitute an alternative for the rational development of drugs. This approach does not require highly purified enzymes or a great amount of protein, but increase the enzymatic stability against heat, organic solvents and pH, without too much loss of catalyst activity. Immobilized enzyme reactors (IMER) can be used for the accomplishment of high efficiency screening on-line and, thus inhibitors can be quickly identified. Here, we emphasize the development of IMER by use of different methods of immobilization and chromatographic supports. Their applications, in different areas of research, are also fully discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrophilic drug sodium alendronate was encapsulated in blended microparticles of Eudragit® S100 and Methocel® F4M or Methocel® K100LV. Both formulations prepared by spray-drying showed spherical collapsed shape and smooth surface, encapsulation efficiencies of 85 and 82% and mean diameters of 11.7 and 8.4 µm, respectively. At pH 1.2, in vitro dissolution studies showed good gastro-resistance for both formulations. At pH 6.8, the sodium alendronate release from the microparticles was delayed and was controlled by Fickian diffusion. In conclusion, the prepared microparticles showed high encapsulation efficiency of sodium alendronate presenting gastro-resistance and sustained release suitable for its oral administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive on-line flow injection system for determination of zinc with FAAS has been described. The method is based on the separation and preconcentration of zinc on a microcolumn of immobilized Alizarin Red S on alumina. The adsorbed analyte is then eluted with 250 µL of nitric acid (1 mol L-1) and is transported to flame atomic absorption spectrometer for quantification. The effect of pH, sample and eluent flow rates and presence of various cations and anions on the retention of zinc was investigated. The sorption of zinc was quantitative in the pH range of 5.5-8.5. For a sample volume of 25 mL an enrichment factor of 144 and a detection limit (3S) of 0.2 µg L-1 was obtained. The precision (RSD, n=7) was 3.0% at the 20 µg L-1 level. The developed system was successfully applied to the determination of zinc in water samples, hair, urine and saliva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.