129 resultados para SOLID-PHASE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the volatile chromatographic profiles of roasted Arabica coffees, previously analyzed for their sensorial attributes, were explored by principal component analysis. The volatile extraction technique used was the solid phase microextraction. The correlation optimized warping algorithm was used to align the gas chromatographic profiles. Fifty four compounds were found to be related to the sensorial attributes investigated. The volatiles pyrrole, 1-methyl-pyrrole, cyclopentanone, dihydro-2-methyl-3-furanone, furfural, 2-ethyl-5-methyl-pyrazine, 2-etenyl-n-methyl-pyrazine, 5-methyl-2-propionyl-furan compounds were important for the differentiation of coffee beverage according to the flavour, cleanliness and overall quality. Two figures of merit, sensitivity and specificity (or selectivity), were used to interpret the sensory attributes studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the organic compounds of cigar samples from different brands were analyzed. The compound extraction was made using the matrix solid-phase dispersion (MSPD) technique, followed by gas chromatography and identification by mass spectrometry (GC-MS) and standards, when available. Thirty eight organic compounds were found in seven different brands. Finally, with the objective of characterizing and discriminating the cigar samples, multivariate statistical analyses were applied to data, e.g.; principal component analysis (PCA) and hierarchical cluster analysis (HCA). With such analyses, it was possible to discriminate three main groups of three quality levels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper evaluates the adsorption capacity of zirconocene-based silica materials in the pre-concentration of antimicrobians (tetracycline, sulfamethoxazole and trimethoprim) in aqueous medium. These materials were prepared by grafting the zirconocene onto silicas pre-treated at different temperatures. The retention capacity of these materials was evaluated by off line SPE and HPLC-UV and the proposed methodology was validated in ultrapure, tap and river water. The recovery for tetracycline was 72% (in the solid phase A) and, for sulfamethoxazole and trimethoprim was 68 and 95% in the commercial C18, respectively. The target antimicrobians were not detected in the Arroio Dilúvio (Porto Alegre - RS).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive preconcentration procedure for spectrophotometeric determination of aluminum was developed. Aluminum as aluminon complex is adsorbed on microcrystalline naphthalene. The naphthalene containing the complex is dissolved in 3 mL of acetone and its absorbance is measured at 544 nm. The effect of various factors on the preconcentration of aluminum was investigated. The calibration graph was linear in the range of 1-60 mg L-1. The limit of detection was 0.52 mg L-1 and relative standard deviation for the determination of 5 mg L-1 was 2.65%. The proposed solid phase extraction procedure was applied to determination of aluminum in food samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A fruit chemical composition reflects its maturation stage. For coffee, it is also the reflex of the post-harvesting processing type, dry, semi-wet and wet. The object of this work was to verify if headspace solid phase microextraction coupled to gas chromatography (HS-SPME-GC) could be used to discriminate between samples harvested in different maturation stages and treated by different processes. With application of principal component analysis to the area of 117 compounds extracted by SPME, using divinylbenzene/Carboxen/polydimethylsiloxane fiber, it was possible to discriminate, in the roasted and ground coffee, the maturity stage and processing type used .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method based on headspace - solid phase microextraction coupled with gas chromatography - mass spectrometry was validated for the quantitative determination of 18 organochlorine pesticides in water. For the extraction conditioning some parameters as the best type of coating fiber, time and temperature of extraction, pH and ionic strength were evaluated. The method HS-SPME/GC-MS/MS showed linear coefficient above 0.9948. The repeatability of the measurements were lower than 7.6%. Relative recoveries were between 88 and 110%. Limits of detection from 0.5 x 10-3 to 1.0 mg L-1 were obtained. A total of 31 samples were analyzed and 16 presented from 1 to 5 pesticides.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The determination of pesticide residues in water samples by Liquid Chromatography require sample preparation for extraction and enrichment of the analytes with the minimization of interferences to achieve adequate detection limits. The Solid Phase Extraction (SPE), Solid Phase Microextraction (SPME), Stir Bar Sorptive Extraction (SBSE) and Dispersive Liquid-Liquid Microextraction (DLLME) techniques have been widely used for extraction of pesticides in water. In this review, the principles of these sample preparation techniques associated with the analysis by Liquid Chromatography with Diode Array Detection (LC-DAD) or Mass Spectrometry (LC-MS) are described and an overview of several applications were presented and discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes an analytical method for analyzing polychlorinated biphenyls in corn samples using solid phase extraction (SPE) followed by determination by GC-MS. All calibration curves proved linear (r> 0.99). Recoveries ranged between 74.1 and 110.6% with relative standard deviation lower than 20% for all compounds. The limits of quantitation for the method were between 0.025 and 0.1 ng g-1. Of the 51 samples analyzed, PCB 180 showed the highest frequency, being detected in more than 39%, followed by PCB 138, detected in more than 33% of samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Considering all the aspects of the principles of green chemistry, we present herein the addition reactions of amines to 1,4-naphthoquinone in water as solvent and also in solid phase. These reactions resulted in very colorful products that were easily monitored by thin layer chromatography and consequently easy to separate. Therefore, they are interesting experiments for experimental organic chemistry in the classrooms or in the laboratories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the levels of plasticizer endocrine disruptors (diethyl phthalate, dibutyl phthalate, and bisphenol A) in drinking water at Paraíba do Sul River region and release of these compounds from bottled water. An analytical method employing solid phase extraction and GC/MS was optimized and validated. The results showed that the method is selective, linear (r² > 0.99), precise (RSD <12%), accurate (recoveries between 62 and 105%), sensitive and robust. Applying the method, the presence of all studied pollutants in drinking water was observed for the three sampled plasticizers. These plasticizers were not found in mineral bottled water, before or after storage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simultaneous solid phase extraction procedure for enrichment of Cu(II), Cd(II) and Mn(II) has been developed. The method is based on adsorption of Cu(II), Cd(II) and Mn(II) ions on polyethylene glycol-silica gel pre-conditioned with acetate buffer (pH 5.5). The adsorbed metal ions are eluted with nitric acid (1 mol L -1) and determined by flame atomic absorption spectrometry. The calibration graph was linear in the range of 2-140 ng mL-1 for Cu(II), 1-40 ng mL-1 for Cd(II) and 4-100 ng mL-1 for Mn(II). The limits of detection were 0.66, 0.33 and 1.20 ng mL-1 for Cu(II), Cd(II) and Mn(II), respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Analytical methods were developed and validated to determine residues of veterinary drugs in buffalo milk and meat, using the QuEChERS method and gas chromatography-mass spectrometry. Both milk and meat, at 2 g of sample, 4 mL of acetonitrile, 0.8 g of MgSO4 and 0.2 g of NaCl, were used in the liquid-liquid partition, whereas 50 mg of C18, 50 mg of PSA and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction (d-SPE). The methods showed sensitivity, precision and accuracy. The quantitation limits were in agreement with the maximum residue limit established by the Codex Alimentarius, FAO and WHO.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.