248 resultados para Coluna interna de Plasma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 <FONT FACE=Symbol>m</font>L of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative analytical method for nitrogen dioxide (NO2) in atmosphere was developed. The collection of NO2 is performed by a Sep-Pack C-18 cartridge impregnated with 11% (v/v) of triethanolamine plus 3,6 % (v/v) of ethylene glycol plus 25 % (v/v) of acetone combined solution. When the impregnating is used, NO2 is collected with good repeatibility (CV = 3,3 %). The NO2 absorbed in the sampler was stripped from the sorbent with a methanol 5% (v/v) aqueous solution and was determined by colorimetry as nitrite by using the Griess-Saltzman reagent. The detection limit of 1,4 ppb for 60 min sampling at 0,5 L min-1 flow rate was obtained. Preparation and conditioning procedures for TEA-C-18 cartridge, sampling flow rate, absorption capacity and interference of other species are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 &micro;m (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a review on internal standardization in atomic absorption spectrometry with emphasis to the systematic and random errors in atomic absorption spectrometry and applications of internal standardization in flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry. The rules for selecting an element as internal standard, limitations of the method, and some comments about the application of internal standardization in atomic absorption spectrometry and the future of this compensation strategy are critically discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work a polyurethane polymer derived from castor oil was used as stationary phase for capillary gas chromatography. The polymer was obtained by reaction of hydroxylated compound and isocynate (NCO), forming urethane. Columns of 7 m x 0,25 mm were then coated with this stationary phase (film thickness of 0,25 µm) using static coating method. The Grob test was also performed. Samples of essential oil of the Aniba duckei Korstermans was then analysed in POLYH4-MD capillary column in order to evaluate its chromatographic perfomance. The linalool was found to be the major component and has been used as compound of departure for many important syntheses. Results show that the experimental columns give higher resolution and can be employed for analysis of essentials oils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 &plusmn; 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 &plusmn; 0.3 mg/g of creatinine).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internal energy dependence of the competitive unimolecular dissociation channels of dimethyl ether were studied with the statistical RRKM formalism. The C-O and C-H fission reactions and the 1,2-H and 1,3-H shifts, and 1,1-H2 and 1,3-H2 molecular eliminations are discussed as a function of energy dependence of k a(E*), the microcanonical rate constant for production of transition states. C-O fission is the dominant process while reaction channels involving C-H fission, 1,1-H2 and 1,3-H2 elimination and production of MeOH should be competitive at energies around 400 kJ mol-1. The less favorable process is the channel of CH4 formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead absorption is influenced by the species that are formed and the physicochemical characteristics of lead, among others. Lead plasma concentration is < 5% of total blood lead and represents the biologically active fraction able to cross the cell membranes. Health risks mainly depend on a specific metal and its species. Speciation analysis is the analytical activity of identifying and determining different metal species. Chromatographic methods are very useful in the identification of species and the techniques most used to determine metals in biological fluids are ICP OES/MS and AAS. Lead speciation analysis in blood plasma is fundamental for understanding and evaluating the interaction mechanisms between that analyte and its biological targets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exhaust emissions of vehicles greatly contribute to environmental pollution. Diesel engines are extremely fuel-efficient. However, the exhaust compounds emitted by diesel engines are both a health hazard and a nuisance to the public. This paper gives an overview of the emission control of particulates from diesel exhaust compounds. The worldwide emission standards are summarized. Possible devices for reducing diesel pollutants are discussed. It is clear that after-treatment devices are necessary. Catalytic converters that collect particulates from diesel exhaust and promote the catalytic burn-off are examined. Finally, recent trends in diesel particulate emission control by novel catalysts are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.