129 resultados para Active Pixel Sensor
Resumo:
A simple, portable and low-cost system for odor detection was developed using a single MOS commercial sensor and a microcontroller. The temperature modulation technique was implemented applying a DC signal pulse to the sensor heater by a bipolar transistor. Two odorant profiles, ethanol and acetic acid vapors, were obtained and distinguished based on their amplitude versus time responses. Response for acetic acid was not reported by the sensor manufacturer. An ethanol vapor calibration curve was also obtained. Experimental data showed a potential behavior according to the theoretical equation of the MOS sensors. Values of logK=0.457 and α=-0.213 for a 95% confidence level were obtained.
Resumo:
A potentiometric Nickel sensor was prepared using 2-hydroxy-1-naphthylidene-N-cyanoacetohydrazone as electro-active material and epoxy resin as a binding material. A membrane composed of 40% Schiff's base and 60% epoxy resin exhibited the best performance. The membrane showed excellent response in the concentration range of 0.15 ppm to 0.1 mol L- 1 Ni+2 ions with non-Nernstian slope of 22.0 mV/decade, had a rapid response time (less than 10 s), and can be used for three months without any considerable loss of potential. The sensor was useful within the pH range of 1.3 to 9.6, and was able to discriminate between Ni2+ and a large number of alkaline earth and transition metal ions. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Ni2+ with EDTA and oxalic acid.
Resumo:
This article presents a discussion on light diffraction by slits and grids as well as the development of an experimental apparatus which provides quantitative observation of the phenomenon. We conducted a brief historical survey on the evolution of the wave theory of light and the role of diffraction in the context of optical spectroscopy. We also reviewed the use of Huygens’ principle to calculate the intensity pattern obtained when light is diffracted by slits and compared the predictions with experimental results obtained using the apparatus developed. Finally, the use of the apparatus in an optical spectroscopy experiment was demonstrated.
Resumo:
Chemically modified electrodes have been studied to obtain new and better electrochemical sensors. Transparent conductive oxides, such as fluorine-doped tin-oxide (FTO), shows electrical conductivity comparable to metals and are potential candidates for new sensors. In this work, FTO was modified by gold electrodeposition from chlorine-auric acid solution using cyclic voltammetry (CV) technique. A set of different materials were produced, varying the scan number. Scanning electron microscopy and electrochemical impedance spectroscopy were performed for the characterization of electrodes surfaces. From this analysis was possible to observe the resistive, capacitive and difusional aspects from all kind of modified electrodes produced, establishing a relationship between this parameters and the scan number. The electrode with 100 scans of CV presented better characteristics for an electrochemical sensor; it has the lowest global impedance and rising of capacitive behavior (related to electrical double layer formation) at lower frequencies. This electrode was tested for paracetamol and caffeine detection. The results showed a high specificity, decreased oxidation potential (0.58 V and 0.97 Vvs. SCE, for paracetamol and caffeine, respectively) and low detection limits (0.82 and 0.052 µmol L-1).
Dióxido de chumbo eletrodepositado sobre grafite como sensor potenciométrico à ions chumbo e sulfato
Resumo:
No presente trabalho, foi desenvolvido um eletrodo de PbO2 eletrodepositado sobre grafite a partir do eletrólito metanosulfonato de chumbo-ácido metanosulfônico contendo o agente tensoativo brometo de cetiltrimetilamônio (BCTA). Foram avaliadas a resposta potenciométrica do eletrodo de PbO2 como sensor à íons Pb2+ e SO4(2-), em pH e força iônica constante. A aplicação deste eletrodo em titulações potenciométricas de precipitação em meio hidro-etanólico também foi investigada. Os resultados demonstraram que o eletrodo de PbO2 eletrodepositado pode ser utilizado como sensor potenciométrico alternativo à íons Pb(II) apresentando uma linearidade na faixa de concentração de 3,98x10-4 a 3,09x10-2 mol L-1 em meio de íons nitrato com limite de detecção de (4,98 ± 0,11)x10-4 mol L-1. Para íons sulfato o eletrodo de PbO2 não responde diretamente porém, estes íons podem ser dosados indiretamente por titulação potenciométrica com solução padrão de Pb(II), em meio ácido, em uma mistura 1:1 (v/v) de etanol-água, com boa definição dos volumes de equivalência. A repetitividade dos potenciais e dos volumes de equivalência obtidos em amostras de concentração milimolar em sulfato, indicam a viabilidade deste eletrodo na dosagem de íons sulfato.
Resumo:
Este trabalho descreve a construção e a determinação de parâmetros físico-químicos com um eletrodo de segunda ordem do tipo, Pt|Hg|Hg2(PAB)2|Grafite, sensível ao íon p-aminobenzoato (PAB). O eletrodo é construído facilmente, apresenta um rápido tempo de resposta, é de baixo custo e tem um tempo de vida útil superior a 12 meses. Utilizando o referido eletrodo foi possível estimar os coeficientes de atividade iônica individuais do PAB, a 25ºC, em força iônica ajustada entre 0,700-3,000 mol L-1 com NaClO4, em solução aquosa. O potencial molal padrão do eletrodo determinado a 25ºC é de (445,5 ± 0,5) mV. A constante termodinâmica do produto de solubilidade, T Kps (I=0) do Hg2(PAB)2 determinada com o eletrodo é de (T Kps = 2,50 x 10-12 mol³ L-3 , a 25ºC). Uma característica favorável consiste no fato de que o eletrodo pode ser utilizado para determinar a concentração de íons p-aminobenzoato livres em sistemas complexos de íons metálicos.
Resumo:
Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensor coated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect of temperature, flow rate, and some possible interferents were carried out. Calibration curves, sensor stability (lifetime) and the precision of measurements were also verified. The resulting selectivity is probably due to the coordinative binding between the electronically unsatured metal complexes and the analyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v).
Resumo:
Neste estudo, procurou-se desenvolver e avaliar filmes para a captação e quantificação de vapores de amônia no ar, através de um sensor piezelétrico de quartzo. Muitas substâncias e suas misturas, em diferentes proporções, foram investigadas como possíveis filmes captores. Em etapas seguintes, verificaram-se alguns parâmetros importantes como o efeito da vazão do poluente, da temperatura de trabalho e da massa da película, otimizando-se as condições experimentais para a montagem do método. Concluiu-se que o filme mais promissor, sob as condições ajustadas, seria uma mistura 2:1 (v/v) de solução comercial (A) de ácido glicólico (70 % m/m) em água, adicionada a tetrakis(hidroxietil)etilenodiamina - THEED (3:4 v/v), com uma solução saturada (B) de ácido tânico em acetona. Estudos de repetibilidade, do tempo de contacto (poluente-sensor) e de alguns possíveis interferentes completaram os trabalhos. As curvas analíticas resultantes mostraram faixas lineares na região de trabalho (2,0 a 11 ppm v ou 1,4 a 7,7 mg/m³ de NH3), para quatro diferentes tempos de exposição (0,5; 1; 2 e 3 min), com coeficientes de correlação (r) variando entre 0,9994 e 0,9980, e respectivas sensibilidades de 13,5 a 42,0 Hz / ppm v.
Resumo:
Citrus tristeza virus (CTV) isolates from 35 grapefruit accessions belonging to Citrus Active Germplasm Bank of the "Instituto Agronômico de Campinas" located at the "Centro APTA Citros Sylvio Moreira", Cordeirópolis, São Paulo state, Brazil, were characterized and evaluated through symptoms in the trees, biological indexing, immunological diagnosis with different monoclonal antibodies and SSCP analysis (single-strand conformation polymorphism) of the coat protein gene. Symptomatology indicated that, in general, the group of plants with smaller canopy volume and severe stem pitting differed significantly from the group that presented greater vegetative development and mild to moderate stem pitting. However, the isolates from most of the accessions induced mild reaction on Mexican lime. The serological evaluation through the DAS-ELISA using monoclonal antibodies did not reveal any association between virus titer in the plant tissue and symptoms. The reaction with different monoclonal antibodies and the distinct electrophoresis patterns obtained through SSCP showed that there is a high degree of diversity among the isolates that infect these grapefruit accessions. High complexity within the same isolate was also observed in the SSCP profiles. This finding indicates that the CTV isolates from these plants are a complex mixture of CTV haplotypes. Similar SSCP banding patterns were observed among some plants with strong stem pitting symptoms, and among some plants with weak or moderate stem pitting symptoms.
Resumo:
The prevailing undergraduate medical training process still favors disconnection and professional distancing from social needs. The Brazilian Ministries of Education and Health, through the National Curriculum Guidelines, the Incentives Program for Changes in the Medical Curriculum (PROMED), and the National Program for Reorientation of Professional Training in Health (PRO-SAÚDE), promoted the stimulus for an effective connection between medical institutions and the Unified National Health System (SUS). In accordance to the new paradigm for medical training, the Centro Universitário Serra dos Órgãos (UNIFESO) established a teaching plan in 2005 using active methodologies, specifically problem-based learning (PBL). Research was conducted through semi-structured interviews with third-year undergraduate students at the UNIFESO Medical School. The results were categorized as proposed by Bardin's thematic analysis, with the purpose of verifying the students' impressions of the new curriculum. Active methodologies proved to be well-accepted by students, who defined them as exciting and inclusive of theory and practice in medical education.
Resumo:
This study evaluates the use of role-playing games (RPGs) as a methodological approach for teaching cellular biology, assessing student satisfaction, learning outcomes, and retention of acquired knowledge. First-year undergraduate medical students at two Brazilian public universities attended either an RPG-based class (RPG group) or a lecture (lecture-based group) on topics related to cellular biology. Pre- and post-RPG-based class questionnaires were compared to scores in regular exams and in an unannounced test one year later to assess students' attitudes and learning. From the 230 students that attended the RPG classes, 78.4% responded that the RPG-based classes were an effective tool for learning; 55.4% thought that such classes were better than lectures but did not replace them; and 81% responded that they would use this method. The lecture-based group achieved a higher grade in 1 of 14 regular exam questions. In the medium-term evaluation (one year later), the RPG group scored higher in 2 of 12 questions. RPG classes are thus quantitatively as effective as formal lectures, are well accepted by students, and may serve as educational tools, giving students the chance to learn actively and potentially retain the acquired knowledge more efficiently.
Resumo:
O Cerrado é formado por um mosaico de fisionomias campestres, savânicas e florestais que possuem um típico ciclo fenológico. Nesse contexto, os dados do MODIS fornecem medidas diárias que permitem monitorar a sazonal fenologia da vegetação. O objetivo deste trabalho foi caracterizar formações savânicas, formações florestais e áreas de cerrado convertido pela ação antrópica, utilizando séries temporais de NDVI e EVI do sensor MODIS, após a suavização de ruídos. A metodologia adotada pode ser subdividida nos seguintes passos: (a) confecção do cubo temporal com NDVI e EVI, onde o perfil em z corresponde à assinatura temporal, (b) tratamento do ruído e (c) detecção das assinaturas temporais. A Transformação pela Fração Mínima de Ruído (MNF) foi aplicada para suavizar ruídos contidos nas séries temporais. Os resultados indicaram que os valores de NDVI foram maiores que os valores de EVI e existiu relação com as estações do ano. As formações florestais foram as que apresentaram maiores valores de NDVI e EVI, possuindo ainda as menores variações entre as estações. As áreas convertidas apresentaram os menores valores dos dois índices, tendo grande queda em seus valores no início da estação seca, provavelmente por se tratar do período de colheita. O estudo concluiu que as séries temporais NDVI e EVI são úteis na diferenciação dos tipos de vegetação.
Resumo:
Imagens NDVI (Índice de Vegetação por Diferença Normalizada) do sensor Modis foram utilizadas para mapear as classes de uso e cobertura da terra nas Serras do Sudeste e Campanha Meridional do Rio Grande do Sul. A metodologia compreendeu a elaboração de um banco de dados espaciais e a aplicação de técnicas de processamento digital (contraste linear, classificação digital e operações aritméticas) sobre imagens dos satélites Landsat e Terra de diversas datas. Os resultados indicaram que a cobertura florestal passou de 8,6% para 11,6% e 14,3% da área total da microrregião Serras do Sudeste, entre os anos 2000, 2004 e 2008. Na Campanha Meridional, a expansão da cobertura florestal passou de 11,1% para 11,2% e 11,5% da área total no mesmo período. Conclui-se que imagens MOD13Q1, de baixa resolução espacial (250 m), podem ser usadas em grandes áreas para mapear florestas e os demais temas adequadamente.
Resumo:
This paper aims to assess the effectiveness of ASTER imagery to support the mapping of Pittosporum undulatum, an invasive woody species, in Pico da Vara Natural Reserve (S. Miguel Island, Archipelago of the Azores, Portugal). This assessment was done by applying K-Nearest Neighbor (KNN), Support Vector Machine (SVM) and Maximum Likelihood (MLC) pixel-based supervised classifications to 4 different geographic and remote sensing datasets constituted by the Visible, Near-Infrared (VNIR) and Short Wave Infrared (SWIR) of the ASTER sensor and by digital cartography associated to orography (altitude and "distance to water streams") of which the spatial distribution of Pittosporum undulatum directly depends. Overall, most performed classifications showed a strong agreement and high accuracy. At targeted species level, the two higher classification accuracies were obtained when applying MLC and KNN to the VNIR bands coupled with auxiliary geographic information use. Results improved significantly by including ecology and occurrence information of species (altitude and distance to water streams) in the classification scheme. These results show that the use of ASTER sensor VNIR spectral bands, when coupled to relevant ancillary GIS data, can constitute an effective and low cost approach for the evaluation and continuous assessment of Pittosporum undulatum woodland propagation and distribution within Protected Areas of the Azores Islands.
Resumo:
Áreas com diferentes potenciais de rendimento dentro de uma lavoura necessitam ser manejadas separadamente, para fins de aplicação da adubação nitrogenada em cobertura. O equipamento baseado em sensoriamento remoto terrestre (GreenSeeker) é um dos instrumentos utilizados para separar diferentes zonas de manejo. Para fazer isso, o sensor permite a definição de classes para estimar o potencial produtivo de forma ágil, precisa e em tempo real. Com o instrumento, foi desenvolvido um modelo para estimativa do potencial produtivo em trigo e cevada, correlacionando o Índice de Vegetação por Diferença Normalizada (NDVI) com a biomassa seca acumulada na parte aérea, por ocasião da emissão da sexta folha do colmo principal. A base do modelo foi a formação de classes de potencial produtivo correspondentes a zonas específicas de manejo da lavoura. Essas classes não necessitam ser específicas para diferentes cultivares e/ou espécies, visto que não se detectaram diferenças que justificassem a formação de grupos para elas. As superfícies de fundo (resíduos de restevas de soja e milho) tiveram efeitos significativos nas leituras do sensor. O modelo continua válido mesmo se as leituras de NDVI forem feitas antes ou após o período recomendado para tal, podendo ser ajustado com sub ou superestimação. As análises de variabilidade espacial, futuramente, podem avaliar se, as zonas de potencial produtivo estimadas pelas classes de NDVI propostas pelo modelo, correspondem à flutuação espacial da biomassa, doses de N aplicadas e rendimento de grãos.