86 resultados para wwPDB validation
Resumo:
The phonological loop is a component of the working memory system specifically involved in the processing and manipulation of limited amounts of information of a sound-based phonological nature. Phonological memory can be assessed by the Children's Test of Nonword Repetition (CNRep) in English speakers but not in Portuguese speakers due to phonotactic differences between the two languages. The objectives of the present study were: 1) to develop the Brazilian Children's Test of Pseudoword Repetition (BCPR), a Portuguese version of the CNRep, and 2) to validate the BCPR by correlation with the Auditory Digit Span Test from the Stanford-Binet Intelligence Scale. The BCPR and Digit Span were assessed in 182 children aged 4-10 years, 84 from Minas Gerais State (42 from a rural region) and 98 from the city of São Paulo. There are subject age and word length effects causing repetition accuracy to decline as a function of the number of syllables of the pseudowords. Correlations between BCPR and Digit Span forward (r = 0.50; P <= 0.01) and backward (r = 0.43; P <= 0.01) were found, and partial correlation indicated that higher BCPR scores were associated with higher Digit Span scores. BCPR appears to depend more on schooling, while Digit Span was more related to development. The results demonstrate that the BCPR is a reliable measure of phonological working memory, similar to the CNRep.
Resumo:
A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.
Resumo:
The objective of the present study was to translate the Kidney Disease Quality of Life - Short Form (KDQOL-SF™1.3) questionnaire into Portuguese to adapt it culturally and validate it for the Brazilian population. The KDQOL-SF was translated into Portuguese and back-translated twice into English. Patient difficulties in understanding the questionnaire were evaluated by a panel of experts and solved. Measurement properties such as reliability and validity were determined by applying the questionnaire to 94 end-stage renal disease patients on chronic dialysis. The Nottingham Health Profile Questionnaire, the Karnofsky Performance Scale and the Kidney Disease Questionnaire were administered to test validity. Some activities included in the original instrument were considered to be incompatible with the activities usually performed by the Brazilian population and were replaced. The mean scores for the 19 components of the KDQOL-SF questionnaire in Portuguese ranged from 22 to 91. The components "Social support" and "Dialysis staff encouragement" had the highest scores (86.7 and 90.8, respectively). The test-retest reliability and the inter-observer reliability of the instrument were evaluated by the intraclass correlation coefficient. The coefficients for both reliability tests were statistically significant for all scales of the KDQOL-SF (P < 0.001), ranging from 0.492 to 0.936 for test-retest reliability and from 0.337 to 0.994 for inter-observer reliability. The Cronbach's alpha coefficient was higher than 0.80 for most of components. The Portuguese version of the KDQOL-SF questionnaire proved to be valid and reliable for the evaluation of quality of life of Brazilian patients with end-stage renal disease on chronic dialysis.
Resumo:
The objective of the present study was to investigate the psychometric properties and cross-cultural validity of the Beck Depression Inventory (BDI) among ethnic Chinese living in the city of São Paulo, Brazil. The study was conducted on 208 community individuals. Reliability and discriminant analysis were used to test the psychometric properties and validity of the BDI. Principal component analysis was performed to assess the BDI's factor structure for the total sample and by gender. The mean BDI score was lower (6.74, SD = 5.98) than observed in Western counterparts and showed no gender difference, good internal consistency (Cronbach's alpha 0.82), and high discrimination of depressive symptoms (75-100%). Factor analysis extracted two factors for the total sample and each gender: cognitive-affective dimension and somatic dimension. We conclude that depressive symptoms can be reliably assessed by the BDI in the Brazilian Chinese population, with a validity comparable to that for international studies. Indeed, cultural and measurement biases might have influenced the response of Chinese subjects.
Resumo:
The purpose of the present study was to examine the factor structure and psychometric properties of the Social Phobia and Anxiety Inventory for Children (SPAI-C), an instrument developed in the United States and applied to a sample of Brazilian schoolchildren. The process included the translation of the original material from English into Portuguese by two bilingual psychiatrists and a back translation by a bilingual physician. Both the front and back translations were revised by a bilingual child psychiatrist. The study was performed using a cross-sectional design and the Portuguese version of the SPAI-C was applied to a sample of 1954 children enrolled in 3rd to 8th grade attending 2 private and 11 public schools. Eighty-one subjects were excluded due to an incomplete questionnaire and 2 children refused to participate. The final sample consisted of 1871 children, 938 girls (50.1%) and 933 boys (49.8%), ranging in age from 9 to 14 years. The majority of the students were Caucasian (89.0%) and the remainder were African-Brazilian (11.0%). The Pearson product-moment correlation showed that the two-week test-retest reliability coefficient was r = 0.780 and Cronbach's alpha was 0.946. The factor structure was almost similar to that reported in previous studies. The results regarding the internal consistency, the test-retest reliability and the factor structure were similar to the findings obtained in studies performed on English speaking children. The present study showed that the Portuguese language version of SPAI-C is a reliable and valid measure of social anxiety for Brazilian children.
Severity score system for progressive myelopathy: development and validation of a new clinical scale
Resumo:
Progressive myelopathies can be secondary to inborn errors of metabolism (IEM) such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA) score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM), covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS), the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1)-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001) and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001) were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.
Resumo:
Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.
Resumo:
The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.
Resumo:
A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS) with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA) in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM) for OTA in coffee.
Resumo:
A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8%) had residues of unauthorized pesticide for the culture of strawberry, one (0.5%) had residues above the maximum residue limit, and another one (0.5%) exhibited both non-conformities.
Resumo:
Abstract The present work describes setting up a laboratory unit for supercritical fluid extraction. In addition to its construction, a survey of cost was done to compare the cost of the homemade unit with that of commercial units. The equipment was validated using an extraction of annatto seeds’ oil, and the extraction and fractionation of fennel oil were used to validate the two separators; for both systems, the solvent was carbon dioxide. The chemical profiles of annatto and fennel extracts were assessed using thin layer chromatography; the images of the chromatographic plates were processed using the free ImageJ software. The cost survey showed that the homemade equipment has a very low cost (~US$ 16,000) compared to commercial equipment. The extraction curves of annatto were similar to those obtained in the literature (yield of 3.8% oil). The separators were validated, producing both a 2.5% fraction of fennel seed extract rich in essential oils and another extract fraction composed mainly of oleoresins. The ImageJ software proved to be a low-cost tool for obtaining an initial evaluation of the chemical profile of the extracts.