97 resultados para reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new electroanalytical method coupling TLC-DPV in solid state was developed for quantitative determination of phytoantioxidants with medicinal purpose, e.g. rosmarinic acid (RA) in samples of phytopharmaceuticals, e.g. rosemary (Rosmarinus officinalis L.). The method showed to be feasible, presenting linearity in concentrations ranging from 0.694 x 10-3 to 9.526 x 10-3 mol L-1 (r = 0.9945), good sensibility, selectivity, reproducibility, repeatability, agility and affordable cost. The concentrations of RA in different extracts of rosemary ranged from 0.05 to 0.52 (% w/w), presenting high recovery levels when compared to HPLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infrared spectroscopy is a versatile technique used for qualitative and quantitative determination of all types of molecular species. As far as analysis of confined or flowing gases is concerned, different types of cell can be found in the market, but they are often very expensive. This study describes the construction of a very efficient gas cell with good reproducibility for qualitative infrared analysis of confined or flowing gases, using easily available and low-cost materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the electrolyte influence on deposition and dissolution processes of Cu nanoparticles on boron doped diamond electrodes (BDD). Morphological, structural and electrochemical analysis showed BDD films with good reproducibility, quality and reversible in a specific redox system. Electrodeposition of Cu nanoparticles on DDB electrodes in three different solutions was influenced by pH and ionic strength of the electrolytic medium. Analyzing the process as function of the scan rate, it was verified a better efficiency in 0,5 mol L-1 Na2SO4 solution. Under the influence of the pH and ionic strength, Cu nanoparticles on DDB may be obtained with different morphologies and it was important for defining the desired properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zeolite-encapsulated complexes have been widely applied in hydrocarbon oxidation catalysis. The "ship-in-a-bottle" encapsulation of iron(III) complexes containing piperazine and piperazine-derivative ligands in zeolite-Y is described. The flexible ligand methodology was employed and the efficiency and reproducibility of the procedure was investigated. The catalysts were characterized employing several techniques and the results indicate the presence of coordinated and uncoordinated iron(III) ions inside and outside the zeolitic cage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use and characterization of the first Certified Reference Material (CRM) of Brazilian coal for analytical quality control are presented. All results were determined within the limits of repeatability and reproducibility allowed under the standards. Notable among the characterization parameters was the mineral matter content (45.39%) obtained by an alternative procedure showing a low relative error (-2.1%) compared to the standard technique (low ashing temperature). The possible expanded application of this CRM application in national laboratories, beyond the certificated and reference parameters, has advantages such as lower cost and easy availability, but round robin tests must be performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Difenoconazole residues in strawberry fruit cultivated in pots were estimated using the solid-liquid extraction with low temperature partition (SLE/LTP) method for sample preparation and gas chromatography with electron capture detection (GC/ECD) for analysis. The optimized method presented excellent recovery values from fortified samples and reproducibility (average recovery values ≥ 98%; CV values < 15%). Linearity of response was demonstrated (r = 0.995) with a detection limit of 9 µg kg-1. The method was successfully applied for the determination of difenoconazole residues in strawberries. Based on these results, the fungicide dissipates quickly, but the residual concentration increases after multiple applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper was to revive the accurate determination of the boiling point of organic compounds using the percolator technique developed in the 1960s. Although this method is simple, fast and efficient it is omitted from current textbooks. This method has several advantages over Siwoloboff such as high reproducibility and direct measurement of the boiling point of the sample obtained by observing the temperature of the vapor-liquid equilibrium. The experiments were performed in the organic chemistry laboratory but allow interdisciplinary integration with other disciplines of several academic areas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Precise surface area is needed for accurate characterization of self-assembled monolayers (SAMs) on metallic surfaces. The aim of this manuscript was to emphasize that miscalculation of surface area is the major source of errors in SAM electrochemical characterization. Limitations are discussed and recommendations given for beginners in analyses of SAM functionalized electrodes. The electrochemical measurements and examples were based on bare gold electrode immobilized with dodecanethiol. The degree of compression of the monolayer properties of formation and reproducibility of the electrochemical response depends on roughness factor, with values closer to the unit being better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel sensitive and relatively selective kinetic method is presented for the determination of V(V), based on its catalytic effect on the oxidation reaction of Ponceau Xylydine by potassium bromate in presence of 5-sulfosalicylic acid (SSA) as activator. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Ponceau Xylydine at 640 nm between 0.5 to 7 min (the fixed time method) in H3PO4 medium at 25ºC. The effect of various parameters such as concentrations of H3PO4, SSA, bromate and Ponceau Xylydine, temperature and ionic strength on the rate of net reaction were studied. The method is free from most interferences, especially from large amounts of V(IV). The decrease in absorbance is proportional to the concentration of V(V) over the entire concentration range tested (1-15 ng mL−1) with a detection limit of 0.46 ng mL-1 (according to statistical 3Sblank/k criterion) and a coefficient of variation (CV) of 1.8% (for ten replicate measurement at 95% confidence level). The proposed method suffers few interferences such as Cr(VI) and Hg(II) ions. The method was successfully applied to the determination of V(V) in tap water, drinking water, bottled mineral water samples and a certified standard reference material such as SRM-1640 with satisfactory results. The vanadium contents of water samples were also determined by FAAS for a comparison. The recovery of spiked vanadium(V) was found to be quantitative and the reproducibility was satisfactory. It was observed that the results of the SRM 1640 were in good agreement with the certified value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine anatomical and functional pelvic floor measurements performed with three-dimensional (3-D) endovaginal ultrasonography in asymptomatic nulliparous women without dysfunctions detected in previous dynamic 3-D anorectal ultrasonography (echo defecography) and to demonstrate the interobserver reliability of these measurements. METHODS: Asymptomatic nulliparous volunteers were submitted to echo defecography to identify dynamic dysfunctions, including anatomical (rectocele, intussusceptions, entero/sigmoidocele and perineal descent) and functional changes (non-relaxation or paradoxical contraction of the puborectalis muscle) in the posterior compartment and assessed with regard to the biometric index of levator hiatus, pubovisceral muscle thickness, urethral length, anorectal angle, anorectal junction position and bladder neck position with the 3-D endovaginal ultrasonography. All measurements were compared at rest and during the Valsalva maneuver, and perineal and bladder neck descent was determined. The level of interobserver agreement was evaluated for all measurements. RESULTS: A total of 34 volunteers were assessed by echo defecography and by 3-D endovaginal ultrasonography. Out of these, 20 subjects met the inclusion criteria. The 14 excluded subjects were found to have posterior dynamic dysfunctions. During the Valsalva maneuver, the hiatal area was significantly larger, the urethra was significantly shorter and the anorectal angle was greater. Measurements at rest and during the Valsalva maneuver differed significantly with regard to anorectal junction and bladder neck position. The mean values for normal perineal descent and bladder neck descent were 0.6 cm and 0.5 cm above the symphysis pubis, respectively. The intraclass correlation coefficient ranged from 0.62-0.93. CONCLUSIONS: Functional biometric indexes, normal perineal descent and bladder neck descent values were determined for young asymptomatic nulliparous women with the 3-D endovaginal ultrasonography. The method was found to be reliable to measure pelvic floor structures at rest and during Valsalva, and might therefore be suitable for identifying dysfunctions in symptomatic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ocelot (Leopardus pardalis) is included in list of wild felid species protected by CITES and is part of conservation strategies that necessarily involve the use of assisted reproduction techniques, which requires practical and minimally invasive techniques of high reproducibility that permit the study of animal reproductive physiology. The objective of this study was to compare and validate two commercial assays: ImmuChem Double Antibody Corticosterone 125I RIA from ICN Biomedicals, Costa Mesa, CA, USA; and Coat-a-Count Cortisol 125I RIA from DPC, Los Angeles, CA, USA, for assessment of fecal glucocorticoid metabolites in ocelots submitted to ACTH (adrenocorticotropic hormone) challenge. Fecal samples were collected from five ocelots kept at the Brazilian Center of Neotropical Felines, Associação Mata Ciliar, São Paulo, Brazil, and one of the animals was chosen as a negative control. The experiment was conducted over a period of 9 days. On day 0, a total dose of 100 IU ACTH was administered intramuscularly. Immediately after collection the samples were stored at 20C in labeled plastic bags. The hormone metabolites were subsequently extracted and assayed using the two commercial kits. Previously it was performed a trial with the DPC kit to check the best extraction method for hormones metabolites. Data were analyzed with the SAS program for Windows V8 and reported as means ± SEM. The Schwarzenberger extraction method was slightly better when compared with the Wasser extraction method (103,334.56 ± 19,010.37ng/g of wet feces and 59,223.61 ± 12,725.36ng/g of wet feces respectively; P=0,0657). The ICN kit detected an increase in glucocorticoid metabolite concentrations in a more reliable manner. Metabolite concentrations (ng/g wet feces) on day 0 and day 1 were 66,956.28 ± 36,786.93 and 92,991.19 ± 28,555.63 for the DPC kit, and 205,483.32 ± 83,811.32 and 814,578.75 ± 292,150.47 for the ICN kit, respectively. The limit of detection for the ICN kit was 7.7 ng/mL for 100% B/Bo (25ng/mL for 88%B/Bo) and for the DPC kit it was 0.2ug/dL for 90.95% B/Bo (1ug/dL for 81.27% B/Bo). In conclusion it was confirmed that the Schwarzenberger extraction method and the ICN kit are superior for extracting and measuring fecal glucocorticoid metabolites in ocelot fecal samples.