119 resultados para basic blue 41


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the oxidation of methylene blue textile dye in the presence of hydrogen peroxide, using niobium oxide impregnated with different proportions of tin (1, 5 and 10% in mass) as catalyst was studied. The materials were characterized by TPR, XPS, XRD and FTIR. The oxidation tests monitored by ESI-MS showed that the composite containing the higher amount of tin was the most efficient in the removal of the dye. The XRD, XPS, and TPR data presented evidence of the formation of the tin-niobium oxide composite containing Sn0 and supported SnO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data of methylene blue number and iodine number of activated carbons samples were calibrated against the respective surface area, micropore volume and total pore volume using multiple regression. The models obtained from the calibrations were used in predicting these physical properties of a test group of activated carbon samples produced from several raw materials. In all cases, the predicted values were in good agreement with the expected values. The method allows extracting more information from the methylene blue and iodine adsorption studies than normally obtained with this type of material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iodide potassium incorporated on mesoporous molecular sieves (SBA-15 and MCM-41) was used as heterogeneous catalysts in the transesterification of sunflower oil under different conditions of reaction time and ratio catalyst/oil (w/w). The results have showed that the system supported in SBA-15 has been more active than the supported in MCM-41, promoting a conversion to methyl esters of 84.98%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to synthesize, characterize and evaluate the application of mesoestruturated catalysts MCM-41, 5%MoO3-MCM-41 and 5%NiO-MCM-41 in the hydrolysis of microcrystalline cellulose. XRD results indicate that the phase of mesoporous MCM-41 was obtained and that the introduction of metal oxides did not affect this mesoporous phase. About the heterogeneous hydrolysis reaction, it was observed that the increase in temperature results in a higher concentration of glucose and the catalyst 5%MoO3-MCM-41 provides the highest concentrations of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT We report on the basic properties of zeolite NaY and potassium supported on NaY (K/NaY) assessed by pyrrole-TPD and MBOH transformation. Pyrrole-TPD revealed that impregnation of zeolite NaY with potassium promoted additional adsorption sites for pyrrole compared to parent zeolite. For zeolite with various potassium loadings, pyrrole adsorbed on K/NaY decreased with increased potassium loading. Reduction in pyrrole adsorption could be due to potassium hindering intrinsic basic sites (lattice oxygen), to oxide of potassium occluding in zeolite cavities restricting access for pyrrole, or to K2O reacting with pyrrole to form nondesorbed pyrrolate anions. On MBOH transformation, potassium almost completely suppressed NaY acid sites while K/NaY basicity increased with potassium loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fresh water sponge was used as a silica source for the synthesis of MCM-41 via the hydrothermal process. The silica was extracted from the sponge by washing with nitric acid and piranha solution. Synthesis of MCM-41 was performed at 100 °C for 5 days and the procedure was optimized, with modifications made to the leaching temperature of the silica and the synthesis of mesoporous material, which was characterized by XRD, FT-IR, SEM and adsorption of N2. The optimal result was achieved at a temperature of 135 °C for 3 days, showing ordered mesoporous material with a surface area of 1080 m² g-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride), volume of dispersant (ethanol), volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD) were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-mesoporous hybrid materials of ZSM-12/MCM-41 type with different micro- and mesoporosity contributions were prepared by a procedure that uses the desilication of the zeolite in an alkaline medium, followed by recrystallization onto the mesostructure, where the zeolite is used as the silica source in the formation of mesoporous phase. The materials were characterized by X-ray diffraction, nitrogen adsorption-desorption at 77 K, scanning electron microscopy and thermal analysis. The results showed that the methodology utilized is efficient for obtaining hybrid materials of ZSM-12/MCM-41 type with optimized micro-and mesoporosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nitrate selective electrode was prepared for use in an aggresive medium (high acidic or basic concentration). It is demonstrated that the depending E graph with respect to pNO3- has not a Nernstian response in concentration acidic range upper 0.1 mol/L H2SO4. The observed behaviour is supposed to be due to the formation of a dimeric anion HN2O6-.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid Ln-OHCO3-DMCP compounds, where Ln represents lanthanides (III) and yttrium (III) ions and DMCP is the anion 4-dimethylaminocinnamylidenepyruvate, have been prepared. Thermogravimetry, derivative thermogravimetry (TG, DTG), differential scanning calorimetry (DSC), x-Ray diffraction powder patterns and elemental analysis have been used to characterize the compounds. The thermal stability as well as the thermal decomposition of these compounds were studied using an alumina crucible in an air atmosphere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption kinetics and equilibrium of methylene blue (MB) onto reticulated formic lignin (RFL) from sugar cane bagasse was studied. The adsorption process is pH, temperature and ionic strength (µ) dependent and obeys the Langmuir model. Conditions for higher adsorption rate and capacity were determined. The faster adsorption (12 hours) and higher adsorption capacity (34.20 mg.g-1) were observed at pH = 5.8 (acetic acid-sodium acetate aqueous buffer), 50 ºC and 0.1 ionic strength. Under temperature (50 ºC) control and occasional mechanical stirring it took from 1 to 10 days to reach the equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple spectrophotometric method for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin with variamine blue is presented. The determination is based on the hydrolysis of β-lactam ring of cephalosporins with sodium hydroxide which subsequently reacts with iodate to liberate iodine in acidic medium. The liberated iodine oxidizes variamine blue to violet colored species of maximum absorption at 556 nm. The absorbance is measured within the pH range of 4.0-4.2. Beer's law is obeyed in the range of 0.5-5.8 µg mL-1, 0.2-7.0 µg mL-1, 0.2-5.0 µg mL-1 and 0.5-8.5 µg mL-1 for cefotaxime, ceftriaxone, cefadroxil and cephalexin respectively. The analytical parameters were optimized and the method is successfully applied for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin in pharmaceuticals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Apresentar os resultados do Hospital Israel Pinheiro - IPSEMG em 41 duodenopancreatectomias realizadas para neoplasias. MÉTODO: Foram coletados dados referentes a 41 pacientes submetidos a duodenopancreatectomias entre 1997 e 2004. A principal operação realizada foi a Whipple "clássica" sem preservação do piloro. A anastomose pancreático-jejunal foi realizada por meio de sutura ducto-mucosa. Foram analisadas a mortalidade e as complicações pós-operatórias. Para avaliar se havia diferença de resultados com a maior experiência da equipe, o estudo foi dividido em dois períodos de quatro anos cada: 1997 a 2000 e 2001 a 2004. RESULTADOS: As complicações pós-operatórias ocorreram em 58% dos casos e a mortalidade foi de 22%. As principais complicações foram pneumonia e infecção de ferida operatória. Quatro pacientes (10%) evoluíram com fistulas pancreáticas, porém obteve-se sucesso com o tratamento conservador em todos os casos. A necessidade de hemotransfusão no peroperatório relacionou-se a um pior prognóstico. Observou-se uma redução das taxas de morbi-mortalidade no período de 2001 a 2004, entretanto sem significância estatística. Os pacientes apresentaram sobrevida global em cinco anos de 35% e de 26% quando considerados apenas aqueles com adenocarcinoma de cabeça de pâncreas. CONCLUSÕES: A duodenopancreatectomia é um procedimento cirúrgico complexo, com elevada morbi-mortalidade. Entretanto, com o aumento da experiência das equipes cirúrgica, anestésica e de medicina intensiva, observa-se uma redução nas taxas de complicação.