172 resultados para Pressure recommended
Resumo:
Each year, there is an increase in pesticide consumption and in its importance of use in the large-scale agricultural production, being fundamental the knowledge of application technology to the activity success. The objective of the present study was to evaluate the influence of working pressure on the drift generated by different spray nozzles, assessed in wind tunnel. The treatments were composed of two spray nozzles AXI 110015 and AXI 11002 with pressure levels of 276 and 414 kPa. The spray solution was composed by water and NaCl at 10%. The applications were conducted at wind speed of 2.0 m s-1, being the drift collected at 5.0; 10.0 and 15.0 m away from the spray boom and at heights of 0.2; 0.4; 0.6; 0.8 e 1.0 m from the tunnel floor. To both spray nozzles, the greatest drift was collected at the smallest distance to the spray-boom and at the lowest height. The AXI 11002 nozzle gave a smaller drift relative to the AXI 110015 nozzle for the two tested pressures and for all the collection points. Regardless of the nozzle, a rise in the working pressure increases the spray drift percentage at all distances in the wind tunnel.
Resumo:
Henhouse thermal comfort and bird age influence broiler breeder hen productivity; this way, the present research aimed to assess thermal comfort indexes and broiler breeder hen performance during winter in North East semi-arid region from Brazil, using a Cobb Avian 48 broiler strain at the age of 38 and 50 weeks. We measured the following bioclimatic indexes: air temperature and relative humidity, black globe temperature and humidity, CO2 concentration and sound pressure levels at henhouse facility. Data analysis design was complete randomized in a 3 x 3 factorial scheme with three treatments (months) and three replications (week number of collection by month). A number of 25 climatic data were observed. Bioclimatic indexes at the most warm hours throughout the day promoted bird discomfort yet sound pressure and carbon dioxide levels were under the Brazilian standards. Even in thermal comfort zone at some hours, the productivity indexes were in compliance with those recommended by the strain creation guidebook.
Resumo:
ABSTRACT The power consumption and load capacity of agricultural machines have grown and the effects of pressure on the soil by tires have been still little investigated. In concern with sustainable development, the relationship machine-tire-soil must be in balance to give more consistency on the best use of tires for a given load. This study aimed to evaluate four tires of two constructive types, the bias belted tires and radial tires, both with respective rim diameters of 22.5 and 26.5 inches with variables measuring the footprint, elastic deformation, sinkage and resistance to penetration. A hydraulic press with an attachment shaft for tire mounting and a box of soil in which the tire has been imposed on a load of 53.00 kN using nominal pressures recommended by the tire manufacturer. The radial construction tire with rim diameter of 26.5 inches obtained less sinkage and resistance to penetration; however, greater elastic deformation and footprint compared to other tires. The bias-belted tire with 22.5-inch rim presented the highest resistance to penetration and the lowest elastic deformation.
Resumo:
ABSTRACT Microsprinkler non-pressure compensating nozzles usually show water flow variation along the lateral line. This study aimed at adapting microtubes into non-compensating system of microsprinklers previous installed in the field, as a self-compensated nozzle, to improve the flow uniformity along the lateral line. Microtubes were adapted to three types of commercial microsprinklers. Tests were conducted, both in the laboratory and in field, to evaluate the microsprinkler performance at four different flows (40, 50, 60 and 70 L h-1) under pressure head range from 75 to 245 kPa. Nozzles presented coefficient of flow-rate variation (CVq) lower than 5.5% and distribution uniformity (DU) greater than 95%, which are classified as excellent. The original spatial water distribution of the microsprinkler did not change by using microtube as a nozzle. This device adapted to non-pressure compensating microsprinklers are functional and operate effectively with flows ranging up to 70 L h-1. Small variations at microsprinkler flows along the lateral line can occur, however, at random manner, which is common for pressure-compensating nozzles. Therefore, the microtube technique is able to control pressure variation in microsprinklers.
Resumo:
ABSTRACT For drip irrigation design and management, it is necessary to know the relation between flow and pressure acting on emitters. In the case of subsurface drip irrigation, the backpressure phenomenon may change the hydraulic characteristics of emitters. Thus, this study aimed at determining such relationship between flow and pressure of different driplines in surface and subsurface conditions; aiming to find possible differences in hydraulic behavior. We tested four emitter types; two pressure compensating (D5000 and Hydro PCND) and two non-pressure compensating (TalDrip and Jardiline). Emitter flow rates were attained in atmospheric conditions and submerged in water, in which submergence levels represented backpressure. Assays were performed using inlet pressures of 80, 100, 120, and 150 kPa for the Hydro PCND dripline and 25, 50, 100, and 150 kPa for the other ones; the backpressures were of 0.49, 1.47, 2.45, 4.41 and 6.37 kPa with four replications. The emitters had their proportionality constants and discharge exponents changed in submerged applications, representing backpressure effect. Non-pressure compensating emitters had their discharge exponent decreased, while in pressure compensating ones, it was increased. Backpressure reduced emitter flow rates at all evaluated pressures.
Resumo:
OBJECTIVE: To evaluate the combined treatment of ear lobe keloids. METHODS: We studied 46 consecutive patients with 81 ear lobe keloids. Patients underwent local infiltration of triamcinolone acetonide (TCN) at concentrations of 40mg/ml (Group 1), 20 mg/ml (Group 2) and 10mg/ml (Group 3). The volume of TCN infiltrate varied according to the size of the lesion. Treatment consisted of three monthly injections before surgery, excision of keloid in the fourth month and perioperative infiltration, followed by two more leaks TCN within two months. Patients used earrings pressure on the scar after operation for four months. The pressure exerted by earrings in the ear lobe was measured electronically. Post-treatment follow-up of patients was 24 months. RESULTS: TCN at concentrations of 20mg/ml and 40mg/ml were effective for the treatment of keloids, no difference between the groups (p = 0.58). However, patients in which TCN was infiltrated the 10mg/ml had poor involution of keloid and the study of this group was stopped. CONCLUSION: the combination of infiltration TCN month to 20 mg/mL (1.2mg to 2.0mg per mm3 TCN injury), surgical excision and pressure application device is effective for treatment of keloid ear lobe.
Resumo:
This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.
Resumo:
The purpose of this study was to establish reference values for selected ophthalmic diagnostic tests in New Zealand rabbits (Oryctolagus cuniculus). A total of 22 adult male rabbits were used. The ophthalmic tests included evaluation of tear production with Schirmer tear test 1(STT1) and Endodontic absorbent paper point tear test (EAPPTT) using two different commercial brand materials. Applanation tonometry, Culture of the conjunctival bacterial flora, , conjunctival cytology and conjunctival histology were also performed. Mean (±SD) for STT1, EAPPTTa, EAPPTTb and IOP was 7.27±2.51mm/min, 12.43±1.69mm/min, 15.24±2.07mm/min, 12.89±2.80mm Hg, respectively. Staphylococcus epidermidis, Staphylococcus sp. and Bacillus sp. were predominant. The cytological evaluation revealed the presence columnar epithelial cells, superficial squamous keratinized cells, lymphocytes, heterophils, red blood cells, mucus and bacteria. The histological analysis revealed a stratified epithelium, characterized by the presence of columnar epithelial cells with a large number of goblet cells. The reported data can be used for therapeutic or experimental purposes.
Resumo:
The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.
Resumo:
Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.
Resumo:
An experimental investigation is performed in a turbulent flow in a seven wire-wrapped rod bundle, mounted in an open air facility. Static pressure distributions are measured on central and peripheral rods. By using a Preston tube, the wall shear stress profiles are experimentally obtained along the perimeter of the rods. The geometric parameters of the test section are P/D=1.20 and H/D=15. The measuring section is located at L/D=40 from the air inlet. It is observed that the dimensionless static pressure and wall shear stress profiles are nearly independent of the Reynolds number and strongly dependent of the wire-spacer position, with abrupt variations of the parameters in the neighborhood of the wires.
Resumo:
Fuel elements of PWR type nuclear reactors consist of rod bundles, arranged in a square array, and held by spacer grids. The coolant flows, mainly, axially along the rods. Although such elements are laterally open, experiments are performed in closed type test sections, originating the appearance of subchannels with different geometries. In the present work, utilizing a test section of two bundles of 4x4 pins each, experiments were performed to determine the friction and the grid drag coefficients for the different subchannels and to observe the effect of the grids in the crossflow, in cases of inlet flow maldistribution.
Resumo:
An experimental apparatus for the study of core annular flows of heavy oil and water at room temperature has been set up and tested at laboratory scale. The test section consists of a 2.75 cm ID galvanized steel pipe. Tap water and a heavy oil (17.6 Pa.s; 963 kg/m³) were used. Pressure drop in a vertical upward test section was accurately measured for oil flow rates in the range 0.297 - 1.045 l/s and water flow rates ranging from 0.063 to 0.315 l/s. The oil-water input ratio was in the range 1-14. The measured pressure drop comprises gravitational and frictional parts. The gravitational pressure drop was expressed in terms of the volumetric fraction of the core, which was determined from a correlation developed by Bannwart (1998b). The existence of an optimum water-oil input ratio for each oil flow rate was observed in the range 0.07 - 0.5. The frictional pressure drop was modeled to account for both hydrodynamic and net buoyancy effects on the core. The model was adjusted to fit our data and shows excellent agreement with data from another source (Bai, 1995).
Resumo:
The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut für Kerntechnik und zertörungsfreie Prüfverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezoresistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow us to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB.
Resumo:
The maintenance of arterial pressure at levels adequate to perfuse the tissues is a basic requirement for the constancy of the internal environment and survival. The objective of the present review was to provide information about the basic reflex mechanisms that are responsible for the moment-to-moment regulation of the cardiovascular system. We demonstrate that this control is largely provided by the action of arterial and non-arterial reflexes that detect and correct changes in arterial pressure (baroreflex), blood volume or chemical composition (mechano- and chemosensitive cardiopulmonary reflexes), and changes in blood-gas composition (chemoreceptor reflex). The importance of the integration of these cardiovascular reflexes is well understood and it is clear that processing mainly occurs in the nucleus tractus solitarii, although the mechanism is poorly understood. There are several indications that the interactions of baroreflex, chemoreflex and Bezold-Jarisch reflex inputs, and the central nervous system control the activity of autonomic preganglionic neurons through parallel afferent and efferent pathways to achieve cardiovascular homeostasis. It is surprising that so little appears in the literature about the integration of these neural reflexes in cardiovascular function. Thus, our purpose was to review the interplay between peripheral neural reflex mechanisms of arterial blood pressure and blood volume regulation in physiological and pathophysiological states. Special emphasis is placed on the experimental model of arterial hypertension induced by N-nitro-L-arginine methyl ester (L-NAME) in which the interplay of these three reflexes is demonstrable