168 resultados para Plasma Heating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d.) using a mobile phase (methanol and water , 90:10, v/v) containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the validation of a method for analyzing the uranium (U) concentration in human urine samples by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) was conducted. PROCORAD (the Association for the Promotion of Quality Control in Radiotoxicological Analysis) provided two urine samples spiked with unknown contents of U (Sample A = 33.6 ± 1.0 µg/L and Sample B = 3.3 ± 0.1 µg/L) and one unspiked sample as a blank. The analyses were directly performed on the diluted urine samples (dilution factor = 1:20) in 5% v/v HNO3. The results obtained by ICP-SFMS corresponded well with the reference values, and the limits of detection were 235U = 0.049 × 10-3 µg/L and 238U = 7.37 × 10-3 µg/L. The ICP-SFMS technique has been shown to be successful in the analysis of the U concentration in human urine samples and for the quantification of isotopic ratios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impacts derived from the emission of volatile organic compounds (VOC) into the atmosphere can have harmful consequences for human health and the environment. In this regard, the present paper proposes the construction of a low-cost cold plasma reactor for the treatment of these compounds. Tests with the prototype were performed to confirm the efficiency for BTEX (benzene, toluene and xylene) samples. Degradation efficiency was confirmed by the gas chromatography method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for ultrasound-assisted extraction and colorimetric determination of iron in soil samples was developed. The iron concentration in the analyzed samples was determined by the colorimetric method and the results compared with inductively coupled plasma mass spectrometry (ICP-MS). Fifteen soil samples were analyzed and the iron concentration results compared with those obtained by ICP-MS using microwave-assisted sample digestion. The proposed procedure showed good efficiency for iron extraction and the results obtained by colorimetric determination exhibited good agreement with ICP-MS. Moreover, ultrasound-assisted extraction and colorimetric determination is a simple, fast and low-cost procedure for application in routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioorganic and biological chemistry have been found to be highly motivating to undergraduate students and in this context, biochemical blood parameter analysis emerges as highly attractive content. In this proposal, several aspects related to analyses of glucose, cholesterol and triglycerides using the enzymatic colorimetric method were involved, and the findings have at least two relevant implications: i) introducing students to connections between organic chemistry and biology based on enzymatic processes, including reactivity and mechanistic aspects; ii) performing a micro scale bioassay analysis. The proposal requires two theoretical classes (2 h per class) and one practical class (4 h).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The air dry-bulb temperature (t db),as well as the black globe humidity index (BGHI), exert great influence on the development of broiler chickens during their heating phase. Therefore, the aim of this study was to analyze the structure and the magnitude of the t db and BGHI spatial variability, using geostatistics tools such as semivariogram analysis and also producing kriging maps. The experiment was conducted in the west mesoregion of the states of Minas Gerais in 2010, in a commercial broiler house with heating system consisting of two furnaces that heat the air indirectly, in the firsts 14 days of the birds' life. The data were registered at intervals of five minutes in the period from 8 a.m. to 10 a.m. The variables were evaluated by variograms fitted by residual maximum likelihood (REML) testing the Spherical and Exponential models. Kriging maps were generated based on the best model used to fit the variogram. It was possible to characterize the variability of the t db and BGHI, which allowed observing the spatial dependence by using geostatistics techniques. In addition, the use of geostatistics and distribution maps made possible to identify problems in the heating system in regions inside the broiler house that may harm the development of chicks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to evaluate and compare the behavior of the heating inside poultry shed through gas hood and underfloor heating. The experiment was conducted in poultry shed belonging to the Federal Institute of Education, Science and Technology of Triângulo Mineiro Region, Uberlândia city – state of Minas Gerais (MG), Brazil. The dimensions of the shed are 24 meters long and 9.6 meters wide and with a ceiling height of 3.2 meters. The temperature was measured with an optical thermometer of Minipa brand, MT 350 model. It was used, to the analysis of temperature behavior, the public domain software FEMM 4.2, which uses finite elements techniques, with data collected from two lots. Underfloor heating is made using hot water flowing through a serpentine type system, which is installed below the bed; this hot water is from solar heaters. An energetic and economic assessment of the warming shed for raising chickens was realized. From the results obtained with the simulations, it may observe that the heating through the floor provides a more homogeneous distribution of temperature when compared with the hood heating. The flow of heat is upwards supplying, thus, the greatest need of heating of the bird, which is the pectoral part.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy consumption in the world has been growing every year. The industrial sector represents 27.32% of the world energy demand. Heating systems that use solar energy may contribute with a percentage of the total energy required by industries. This work aimed to study the use of vacuum solar collectors for water pre-heating in boilers. We used four collectors installed according to NBR 15,569; water flow through the tubes was 0.058 L/s, and temperature in the inlet and outlet pipes was measured. Results showed that instantaneous radiation, and inlet fluid and room temperatures are variables that influence the process, reaching water maximum temperature in the solar collector outlet of 97.9 °C, and efficiency of approximately 65% for most experiments. For the financial viability evaluation, the payback study was applied, which resulted in 4; 7 and 5 years, for the respective sources: firewood, LPG (liquefied petroleum gas), and electricity. Regarding the calculation of the annual contribution to the reduction of greenhouse gases, it was, respectively, 2.162 and 356 kg of CO2 per m² of collector tubes, in comparison with firewood and LPG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estabelecer um método barato e eficiente de preparação do plasma rico em plaquetas e fatores de crescimento para utilização em cirurgia plástica. MÉTODO: Foram realizados 20 testes através de centrifugação de sangue, variando-se a força e o tempo de centrifugação, para determinarmos o melhor método que proporcione uma maior concentração plaquetária e mais 10 testes para comprovar a reprodutibilidade do método. RESULTADOS: A utilização de uma força de centrifugação de 300 g por 10 minutos na 1ª. centrifugação e de 640 g por 10 minutos na 2ª. centrifugação obtiveram as maiores concentrações plaquetárias, superiores a 4,5 vezes a concentração na amostra, e os testes foram reprodutíveis. CONCLUSÕES: Uma alta concentração plaquetária pode ser obtida por este protocolo de obtenção de plasma rico em plaquetas e fatores de crescimento e a formação do gel é possível através da utilização de trombina autóloga, também obtida pelo protocolo descrito, facilitando sua utilização em cirurgia plástica, onde vem mostrando bons resultados na cicatrização de feridas e na integração de enxertos ósseos e cutâneos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Definir qual a melhor potência a ser empregada de forma a atingir a profundidade necessária para ablação com o menor número de sintomas pós-procedimento. MÉTODO: Foram estudados 28 pacientes com esôfago de Barrett, após tratamento cirúrgico do refluxo ou em uso de bloqueadores de bomba de prótons, submetidos à ablação endoscópica, randomizados em dois grupos com potências diferentes - 50 ou 70W. Imediatamente após, foram realizadas biópsias endoscópicas das áreas fulguradas. A sintomatologia foi avaliada por questionário telefônico. RESULTADOS: Não houve diferença entre os grupos quanto a idade, a extensão do esôfago de Barrett, a porcentagem da circunferência esofagiana coagulada e a duração dos sintomas. A dor foi o sintoma predominante e a disfagia ocorreu de forma transitória. Houve correlação negativa moderada entre número de sintomas e potência (potência mais baixa com maior número de sintomas), porém sem diferença significativa. Em 40% dos casos em que se utilizou menor potência obteve-se fragmentos que atingiram apenas a porção superficial da mucosa, o que só ocorreu em 10% dos casos no grupo de 70W. Não foi observada diferença significativa entre a potência utilizada ou o acometimento da muscular da mucosa e o número de sintomas. CONCLUSÕES: A utilização de potência de 70W durante a coagulação do esôfago de Barrett com plasma de argônio sugere associação com menor incidência de metaplasia colunar especializada residual abaixo do epitélio escamoso neoformado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O plasma autólogo começou a ser estudado na década de 90, principalmente por suas propriedades adesivas, de angiogênese e pela presença de fatores de crescimento de origem plaquetária. Na verdade, o plasma pode ser isolado de modo autólogo, a partir do sangue do próprio paciente e obtido nas suas duas porções: uma com alta concentração de plaquetas (plasma rico em plaquetas- PRP) e outra com concentração baixa de plaquetas (plasma pobre em plaquetas- PPP). O presente estudo está em desenvolvimento no Hospital Universitário Clementino Fraga Filho, da Universidade Federal do Rio de Janeiro (HUCFF-UFRJ) e no Hospital Naval Marcílio Dias (HNMD), ambos no Rio de Janeiro. O objetivo é avaliar as propriedades do plasma pobre em plaquetas, principalmente a sua ação adesiva, em pacientes com indicação de dermolipectomia abdominal reparadora, de modo a reduzir as coleções no pós operatório, como hematoma e seroma, duas das principais complicações nesse tipo de cirurgia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar a eficácia da complementação por coagulação com plasma de argônio para reduzir a taxa de neoplasia residual ou recorrente após ressecção endoscópica completa fragmentada de grandes adenomas sésseis colorretais. MÉTODOS: critérios de inclusão: pacientes com grandes adenomas colorretais sésseis, > 20mm, sem sinais morfológicos de infiltração profunda, submetidos à ressecção endoscópica completa fragmentada estudada com cromoendoscopia e magnificação de imagens. Os pacientes foram randomizados em dois grupos: grupo 1 - nenhum procedimento adicional e, grupo 2 - complementação por coagulação com plasma de argônio. O seguimento por colonoscopia foi realizado em três, seis e 12 meses de pós-operatório. Foi avaliada a taxa de neoplasia residual ou recidiva local. RESULTADOS: foram incluídos no estudo um total de 21 lesões. Onze lesões no grupo 1 e dez no grupo 2. Ocorreram duas neoplasias residuais ou recorrências locais em cada grupo, detectadas em três meses de acompanhamento. CONCLUSÃO: a complementação por coagulação com plasma de argônio após uma aparente ressecção endoscópica completa em fragmentos de grandes adenomas sésseis colorretais não parece reduzir a ocorrência de lesão adenomatosa residual ou recidiva local.