112 resultados para Organic compounds -- Synthesis
Resumo:
The aim of this review is to present and discuss the applications of ultrasound in electrochemical systems such as in sonoelectroanalysis and sonoelectrolysis for the electrochemical combustion of organic compounds. Initially, theoretical and experimental aspects are discussed, particularly those related to the enhancement of mass transport and the surface cleaning effects. Some results are included to illustrate alternative geometries for the experimental measurements and the working electrodes used in these systems. In the sequence, the available publications are presented and discussed to demonstrate that ultrasound combined with electrochemical techniques is a powerful set-up for the detection of analytes such as metals and/or organic compounds in hostile media and for the effective destruction of toxic organic substances. At the end, a table summarizes the results already published in the literature.
Resumo:
This work describes novel materials based on pure iron oxide and iron oxide/niobia composite to produce a magnetic adsorbent. These materials were prepared with synthetic iron oxide and characterized by powder XRD, SEM, FTIR, TPR and Mössbauer spectroscopy. Results showed that the main iron oxides formed were goethite (aFeOOH) and maghemite (gFe2O3) with small particle size. The iron oxide and iron oxide/niobia composite showed high adsorption ability for organic compounds. The positive enthalpy indicated an endothermic adsorption process suggesting physical adsorption.
Resumo:
This paper describes the procedures for analysing pollutant gases emitted by engines, such as volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene) by using high resolution gas chromatography (HRGC). For IC engine burning, in a broad sense, the use of the B10 mixture reduces drastically the emissions of aromatic compounds. Especially for benzene the reduction of concentrations occurs at the level of about 24.5%. Although a concentration value below 1 µg mL-1 has been obtained, this reduction is extremely significant since benzene is a carcinogenic compound.
Resumo:
The field of application of mass spectrometry (MS) has increased considerably due to the development of ionization techniques. Other factors that have stimulated the use of MS are the tandem mass spectrometry (MS/MS) and sequential mass spectrometry (MSn) techniques. However, the interpretation of the MS/MS and MSn data may lead to speculative conclusions. Thus, various quantum chemical methods have been applied for obtaining high quality thermochemical data in gas phase. In this review, we show some applications of computational quantum chemistry to understand the formation and fragmentation of gaseous ions of organic compounds in a MS analysis.
Resumo:
This work presents three operationally simple laboratory protocols for monocrystal growth of small-molecule organic compounds, which have been applied with success in the last ten years for the formation of single crystals for X-ray structural studies. In addition, five structure hints were formulated as general guidelines for selecting a small-molecule organic compound as a candidate for monocrystal growth: molecular weight >200 D, melting point >100 ºC, two or more aromatic rings in the structure, at least two sites for intermolecular hydrogen bond formation, and a halogen or other heavy atom in the structure.
Resumo:
This work describes the use of clinoptilolite for removal of ammonium ions present in waters produced at the Campos' Basin. Samples were previously treated in order to remove organic compounds and metals. Experiments were run in fixed- and fluidized-bed systems, at room temperature. The fluidized-bed systems did not remove efficiently the ammonium ion. The best operational conditions were obtained with clinoptilolite particle size in the range 0.30-0.50 mm, under ascendant flow (3 mL min-1), in a fixed-bed system. The best zeolite performance was found when it was pretreated with 0.5 mol L-1 NaOH. Na+ was the most important interfering ion due to its high concentration in the water. Clinoptilolite lost partially its capacity to retain ammonium ions after several regeneration cycles with NaOH.
Resumo:
Plastic packaging materials intended for use in food packaging is an area of great interest from the scientific and economic point of view due to the irreversible internationalization and globalization process of food products. Nevertheless, a debate related to food safety aspects has emerged within the scientific community. Therefore, the development of analytical methods that allow identifying and quantifying chemical substances of toxicological potential in the packaging is considered essential. This article focuses on the main analytical methods, including validation parameters, as well as extraction and quantification techniques for determination of volatile organic compounds from food packaging materials.
Resumo:
A novel solventless sample preparation, stir-bar sorptive extraction (SBSE), for extraction, and sample enrichment of organic compounds from biological fluids, is described in this manuscript from principle to applications. The SBSE is based on sorptive extraction, whereby the compounds are extracted into a polymer coating, polydimethylsiloxane (PDMS), on a magnetic stirring rod. The extraction is controlled by the partitioning coefficient of drugs between the PDMS and sample matrix, and upon the sample-extraction medium phase ratio. The SBSE technique has been applied successfully, with high sensitivities, to biomedical analysis of volatiles and for semi-volatiles drugs from biological sample, including urine, plasma, and saliva. SBSE combined with in situ derivatization, drugs quite more polar (e.g. metabolites) also can be analyzed.
Resumo:
High copper content is of great concern among producers of sugar-cane spirits who frequently use filters instead of cleaning the stills. This study compared the efficiency of activated carbon, ion-exchange-polymeric resin, and activated-carbon/iron-oxide magnetic composite for copper reduction without removing excessive organic compounds that are important for the beverage's quality. Resin was the most efficient copper adsorbent, removing fewer organic compounds. The composite also removed copper; however, it also removed large amounts of organic compounds. Activated carbon didn't remove sufficient copper to reduce its concentration to less than 5 g L-1, and it removed large amounts of higher alcohols and esters.
Resumo:
This work aimed to quantify some organic compounds in "cachaças" (sugar cane spirit). The ethyl alcohol was quantified by densimetry, after distillation. The acetic acid, methyl alcohol, n-propyl alcohol, n-butyl alcohol, isobutyl alcohol, isoamyl alcohol (mixture of 2-methyl-butyl and 3-methyl-butyl), ethyl acetate and acetaldehyde were determined by gas chromatography; and the furfural, 5-hydroxy-methylfurfural and acrolein by high efficiency liquid chromatography. From the 30 samples analyzed, 63.3% showed non-conformity with national legislation regarding at least one of the analyzed components.
Resumo:
This article proposes an experimental procedure to determine the enthalpy (and entropy) of vaporization of organic liquid compounds, by the Smith-Menzies (isoteniscope) method. The values of vapor pressure at different temperatures were obtained and ΔvH (and ΔvS) were graphically determined, using the Clausius-Clapeyron equation. The results for diethyl-ether, propanone, ethanol and n-hexane are in very good agreement with those from literature. A historical and thermodynamic discussion on equations that correlates vapor pressures and temperature precedes the experimental proposition.
Resumo:
This work shows results on the characterization, by liquid chromatography coupled to high resolution tandem mass spectrometry (LC-IT-TOF-MS) with electrospray ionization, of organic compounds present in raw and treated effluents from a combined sewage treatment systems (upflow anaerobic sludge blanket-trickling filter). The sewage samples were prepared by C18 solid phase extraction and the spectra obtained from the various extracts were submitted to principal component analysis to evaluate their pattern and identify the major deprotonated species. Some target compounds were submitted to semiquantitative analysis, using phenolphtalein as internal standard. The results showed the anaerobic step had little impact on the removal of anionic surfactants (LAS), fatty acids, and some contaminantes such as bisphenol A and bezafibrate, whereas the aerobic post-treatment was very efficient in removing these organics.
Resumo:
Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 μg/m³), NO2 (40.3 μg/m³), VOCs (10.3 μg/m³), formaldehyde (1.03 μg/m³) and bioaerosols (1634 CFU/m³), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.
Resumo:
Silver nanoparticles (AgNPs) were prepared by means of the polyol method in the absence of stabilizing polymers. To accomplish this objective, AgNO3 was added to ethylene glycol in the presence of NaOH (1 mol.L-1), the suspension formed was irradiated with a microwave source for 60 seconds at a power of 465 watts. It was found that under these conditions AgNPs of sizes between 4-18 nm are formed. Also the results indicate that part of the ethylene glycol is oxidized to carbonyl compounds that reduce the Ag+. These organic compounds are adsorbed on the surfaces of AgNPs, forming a protective film that prevents their aggregation.
Resumo:
The objective of this work was to evaluate the presence of benzo(a)pyrene (BaP), ethyl carbamate (EC) and methanol in 61 samples of cachaça. The quantification of BaP was carried out using HPLC with fluorescence detection, EC concentrations was determined by GC/MS and that of methanol, by GC/FID. In all samples, the concentration of methanol remained below 5 mg 100 mL-1 absolute alcohol. The results of BaP varied from <0.03 to 0.86 μg L-1; the values of EC exceeded the limit established by Brazilian legislation (150 μg L-1) in 53% of the samples.