155 resultados para Flame Ionization


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is the development of simple strategies to teach basic concepts of atomic spectrometry. Metals present in samples found in the daily lives of students are determined by flame atomic emission spectrometry (FAES). FAES is an accurate, precise, and inexpensive analytical method often used for determining sodium, potassium, lithium, and calcium. Historical aspects and their contextualization for students are also presented and experiments with samples that do not require pre-treatment are described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid phase extraction (SPE) in C18 disks has been optimized and validated for extraction of 5 organophosphorus (OP) pesticides in water. Extraction has been followed by separation and detection by gas chromatography/flame photometry. Excellent linearity was obtained for all compounds (r greater than 0.99), with CVs between 1.0-6.9%, recoveries between 73-95% and quantification limits between 2.5-5.0 µg L-1. Samples from Furnas dam were analyzed monthly during one year and 10% showed OP pesticide residues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have produced nanocomposite films of Ni:SiO2 by an alternative polymeric precursor route. Films, with thickness of ~ 1000 nm, were characterized by several techniques including X-ray diffraction, scanning electron microscopy, atomic force microscopy, flame absorption atomic spectrometry, and dc magnetization. Results from the microstructural characterizations indicated that metallic Ni-nanoparticles with average diameter of ~ 3 nm are homogeneously distributed in an amorphous SiO2 matrix. Magnetization measurements revealed a blocking temperature T B ~ 7 K for the most diluted sample and the absence of an exchange bias suggesting that Ni nanoparticles are free from an oxide layer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nitrogen content in natural gas was studied in experimental and computational investigations to identify its influence on the emission level of exhaust gases from combustion facilities. Changes in natural gas composition with different N2 concentrations may result from introducing a new source gas into the system. An industrial burner fired at 75 kW, housed in a laboratory-scale furnace, was employed for runs where the natural gas/N2 proportion was varied. The exhaust and in-furnace measurements of temperature and gas concentrations were performed for different combustion scenarios, varying N2 content from 1-10 %v. Results have shown that the contamination of natural gas with nitrogen reduced the peak flame temperature, the concentration of unstable species, the NO X emission level and the heat transfer rate to the furnace walls, resulting from the recombination reactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An overview of the current literature on the chemical processes involved in the ion formation from low molecular weight organic compounds by electrospray ionization mass spectrometry is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novel and quantitative mass spectrometry methods for rapid and accurate enantiomeric excess determination are presented. These methodologies use electrospray ionization (ESI) and mass spectrometry (MS) to detect and analyze, via collision-induced dissociation (CID), mass-selected transition metal complexes that promote enantio especific interactions. The data from CID are conveniently treated by the kinetic method, a sensitive linear free energy method of treating mass spectrometric results. Four different variations of this methodology are described: single ratio method (S R), quotient ratio method (Q R), fixed ligand method (S Rfixed), and quotient ratio method with fixed ligand (Q Rfixed). These individual methods are compared and their main features discussed in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper focuses: (i) the development of a measurement technique for the determination of atmospheric C2-C6 hydrocarbons with sampling in canisters and analysis by gas chromatography/flame ionisation detector (GC/FID), (ii) the improvement of an existent adsorption-sampling technique with Tenax TA tubes for the determination of C6-C11 hydrocarbons and analysis by GC/FID after thermal desorption and cryogenic concentration, (iii) the identification of compounds present in ambient air by gas chromatography/mass spectrometry (GC/MS) for both canister and Tenax samples, (iv) a program of interlaboratorial comparison for quality control of C2-C11 analyses, and (v) the seasonal characterisation of ambient air C2-C11 hydrocarbons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polarizability correlates well with organic ion stabilization in solution and can be defined as a measure of the relative ease of the distortion of the electronic cloud of a dipolar system exposed to an external electric field. The effective atomic polarizability, alphad, has a fundamental influence on chemical reactivity in the gas phase and in solution. In terms of chemical reactivity the charge is generated within the molecule as a positive charge due to protonation, ionization or resulting from the attack of a nucleophilic anion. In this paper, lipoidal diaminedithiol (DADT) perfusion radioligands based on 99Tc m and possessing an alkylamine side chain have been used to check the influence of alphad on their brain uptake. Some new DADT derivatives, respectively DADT-DIPA (diaminedithiol - diisopropylamine), DADT DIBA (diaminedithiol diisobutylamine), DADT-PR (diaminedithiol - branched pyperidine), have been designed to have high nitrogen alkylamine alphad values. In spite of the fact of higher alphad values having been correlated to higher brain uptakes, there isn't a clear mechanism able to trap these radioligands into the brain space.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concentrations of Fe, Mn, Co, Cr, Zn and Cu were determinated using flame atomic absorption spectrometry in nine lichen species of the Sul-Mato-Grossense cerrado. The average metal ion concentrations varied in the following ranges: Fe, 248.41-1568.01; Mn, 98.50-397.33; Co, 10.08-24.81; Cr, 18.24-44.26; Zn, 14.62-34.79 and Cu, 3.23-7.57 mg kg-1. Statistical analysis (Pearson and Cluster) applied to the metal ion concentrations indicated that the accumulation of these ions can be due to several anthropogenic sources including agricultural activities, mineral exploration, biomass burning, soil mineral composition and leather tanning processes by chromium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Butyltin compounds were investigated in surface sediments from 17 stations in Todos os Santos Bay. Analytical conditions for organotin determination in marine sediments were optimized for GC with pulsed flame photometric detection. Detection limits were: 5.4 µg kg-1 for TBT; 0.2 µg kg-1 for DBT; and 2.1 µg kg-1 for MBT, using a 610-nm filter. In general, TBT concentrations were low and in the range of

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The field of application of mass spectrometry (MS) has increased considerably due to the development of ionization techniques. Other factors that have stimulated the use of MS are the tandem mass spectrometry (MS/MS) and sequential mass spectrometry (MSn) techniques. However, the interpretation of the MS/MS and MSn data may lead to speculative conclusions. Thus, various quantum chemical methods have been applied for obtaining high quality thermochemical data in gas phase. In this review, we show some applications of computational quantum chemistry to understand the formation and fragmentation of gaseous ions of organic compounds in a MS analysis.