103 resultados para Digital radiology
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
Objective To construct a Portuguese language index of information on the practice of diagnostic radiology in order to improve the standardization of the medical language and terminology. Materials and Methods A total of 61,461 definitive reports were collected from the database of the Radiology Information System at Hospital das Clínicas – Faculdade de Medicina de Ribeirão Preto (RIS/HCFMRP) as follows: 30,000 chest x-ray reports; 27,000 mammography reports; and 4,461 thyroid ultrasonography reports. The text mining technique was applied for the selection of terms, and the ANSI/NISO Z39.19-2005 standard was utilized to construct the index based on a thesaurus structure. The system was created in *html. Results The text mining resulted in a set of 358,236 (n = 100%) words. Out of this total, 76,347 (n = 21%) terms were selected to form the index. Such terms refer to anatomical pathology description, imaging techniques, equipment, type of study and some other composite terms. The index system was developed with 78,538 *html web pages. Conclusion The utilization of text mining on a radiological reports database has allowed the construction of a lexical system in Portuguese language consistent with the clinical practice in Radiology.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57%) patients. Such individuals presented with a total of 29 (41.43%) carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50) of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001) was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.
Resumo:
Objective To investigate the process of learning on human resource management in the radiology residency program at Escola Paulista de Medicina – Universidade Federal de São Paulo, aiming at improving radiologists' education. Materials and Methods Exploratory study with a quantitative and qualitative approach developed with the faculty staff, preceptors and residents of the program, utilizing a Likert questionnaire (46), taped interviews (18), and categorization based on thematic analysis. Results According to 71% of the participants, residents have clarity about their role in the development of their activities, and 48% said that residents have no opportunity to learn how to manage their work in a multidisciplinary team. Conclusion Isolation at medical records room, little interactivity between sectors with diversified and fixed activities, absence of a previous culture and lack of a training program on human resources management may interfere in the development of skills for the residents' practice. There is a need to review objectives of the medical residency in the field of radiology, incorporating, whenever possible, the commitment to the training of skills related to human resources management thus widening the scope of abilities of the future radiologists.
Resumo:
AbstractObjective:The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services.Materials and Methods:Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares.Results:In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others.Conclusion:Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies.
Resumo:
Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.
Resumo:
This work describes the evolution of temperature measurement in the last four centuries using thermometers based on the thermal expansion of liquids such as ethyl alcohol and mercury. The concept of temperature was strongly dependent on the researcher and there was no systematic temperature scale for universal use. The precursor of the common thermometer was the thermoscope, probably invented at the end of the XVIth century. In the XVIIIth century the instrument was greatly improved and several thermometric scales were proposed some of which have been in use until now. These scales were based on arbitrary points. Mercury and ethyl alcohol were the most employed thermometric fluids. In the XIXth century, the concept of absolute zero was a great advance in this field. The most important contribution during the XXth century was the establishment of international temperature scales. The design of the thermometer has been essentially the same along the last 300 years, but many models were proposed for industrial and research purposes. Its association with the densimeter was of great importance for control of industrial chemical processes and also for teaching purposes in the past. Nowadays, there is a clear tendency to replace mercury-based thermometers by electronic digital models. Thermochemistry is the natural relationship between temperature and chemistry.
Resumo:
This work describes the establishment of the concept of pH and the evolution of its measurement. The origin of the pH definition can be found in the development of the chemistry of aqueous solutions during the XIXth century. The electrolytic dissociation theory by Svante Arrhenius played a central role. After the proposal of the pH scale by Sörensen, many years were necessary for the acceptance of this new parameter among chemists in general. Its importance was first recognized in biochemistry and related areas. Twenty years after, its importance had been recognized in many industrial and laboratorial practices. The previous methods were based on colorimetric and electrometric methods, but both suffered from many problems. Acceptance of pH in Chemistry was only possible after the development of experimental trustable measurements. The invention of the pH meter was the primordial step.
Resumo:
A utilização de matéria-prima de origem florestal aumentou significativamente nas últimas décadas. A busca por alta produtividade concretizou-se com a introdução de espécies exóticas, principalmente Eucalyptus sp. e Pinus sp. Neste trabalho avaliou-se a precisão da classificação digital obtida no levantamento de povoamentos florestais implantados e naturais da área da carta de Cachoeira do Sul - RS, utilizando técnicas de geoprocessamento, sensoriamento remoto, SIG (sistema de informação geográfica) e GPS (sistema de posicionamento global). Verificou-se que a área é ocupada por vegetação natural (35,54%), Pinus sp. (1,89%) e Eucalyptus sp. (0,77%), cuja precisão na classificação supervisionada digital foi: Exatidão global (85,23%), Kappa (84,90%) e Tau (77,74%). Concluiu-se que os três índices de acurácia podem ser utilizados, apesar de os índices Kappa e Tau mostrarem-se mais consistentes.
Resumo:
Dados de sensoriamento remoto têm sido largamente utilizados para classificação da cobertura e uso da terra, em particular graças à aquisição periódica de imagens de satélite e à generalização dos sistemas de processamento digital de imagens, que oferecem uma variedade de algoritmos de classificação de imagens. Este trabalho teve por objetivo avaliar alguns dos métodos mais comuns de classificações supervisionadas e não supervisionadas para imagens do sensor TM do satélite Landsat-5, em três áreas com diferentes padrões de paisagem em Rondônia: (1) áreas de fazendas de "Médio porte", (2) assentamentos no padrão "Espinha de peixe" e (3) áreas de contato entre floresta e "Cerrado". A comparação com um mapa de referência baseado na estatística Kappa produziu indicadores de desempenho bons ou superiores (melhores resultados - K-médias: k = 0,68; k = 0,77; k = 0,64 e MaxVer: k = 0,71; k = 0,89; k = 0,70, respectivamente nas três áreas citadas), para os algoritmos utilizados. Os resultados indicaram que a escolha de um algoritmo deve considerar tanto a capacidade de discriminar várias assinaturas espectrais em diferentes padrões de paisagem quanto a relação custo/benefício decorrente das várias etapas do trabalho dos operadores que elaboram um mapa de cobertura e uso da terra. Este trabalho apontou a necessidade de esforço mais sistemático de avaliação prévia de várias opções de execução de um projeto específico antes de se iniciar o trabalho de elaboração de um mapa de cobertura e uso da terra.
Resumo:
A análise completa de tronco é bastante aplicada em estudos de crescimento de espécies florestais que apresentam anéis de crescimento distinguíveis. As medições dos anéis são feitas manualmente com régua milimetrada, procedimento estabelecido como convencional. Porém, Rosot et al. (2003) desenvolveram procedimentos para que essas medições sejam feitas por programas de computador, trazendo avanço significativo para a aplicação da técnica. Assim, o objetivo deste trabalho foi comparar as medições manuais com as digitais em análise de tronco de Mimosa scabrella e Pinus taeda. Seis árvores de cada espécie foram utilizadas, e as diferenças entre os dois procedimentos para DAP (cm), altura total (m), área transversal (cm²) e volume (cm³) de cada anel de crescimento foram comparadas com um teste t(0,05)de dados pareados. As diferenças entre as medições manuais e as digitais foram significativas apenas para o volume do P. taeda em algumas idades. Os resultados indicam que a anatro digital é uma boa opção para a anatro convencional, demandando pessoa treinada para utilizar as ferramentas de Sistema de Informações Geográficas (SIG).
Resumo:
A regionalização de vazões tem sido realizada com o objetivo de disponibilizar informações hidrológicas em locais sem dados ou com poucas informações disponíveis, porém a determinação das características físicas das bacias de drenagem para cada local de interesse limita consideravelmente a aplicação dos resultados de um estudo convencional de regionalização de vazões. Uma das soluções para esse problema é a automação do processo de delimitação de bacias, utilizando-se de modelo digital de elevação hidrologicamente consistente (MDEHC). O objetivo principal deste trabalho foi a regionalização de vazões máxima, mínima e média de longo período e da curva de permanência para a bacia hidrográfica do Rio Paraíba do Sul, a montante da cidade de Volta Redonda, com base em um MDEHC. O modelo digital de elevação mostrou-se hidrologicamente consistente, possibilitando, assim, a determinação automática das características físicas da bacia. Foram identificadas quatro regiões hidrologicamente homogêneas e obtidas equações de regressão em que a área de drenagem e o comprimento do curso d'água principal se caracterizaram como as variáveis mais expressivas para a representação das diversas variáveis e funções regionalizadas.
Resumo:
Surface area (SA) of poultry is an important parameter for heat and mass transfer calculations. Optical approaches, such as the moiré technique (MT), are non-destructive, result in accuracy and speed gains, and preserve the object integrity. The objective of this research was to develop and validate a new protocol for estimating the surface area (SA) of broiler chickens based on the MT. Sixty-six Ross breed broiler chickens (twenty-seven male, thirty-nine female, ages spanning all growth phases) were used in this study. The dimensions (length, width and height) and body mass of randomly selected broiler chickens were evaluated in the laboratory. Chickens were illuminated by a light source, and grids were projected onto the chickens to allow their shape to be determined and recorded. Next, the skin and feathers of the chickens were removed to allow SA to be determined by conventional means. These measurements were then used for calibration and validation. The MT for image analysis was a reliable means of evaluating the three-dimensional shape and SA of broiler chickens. This technique, which is neither invasive nor destructive, is a good alternative to the conventional destructive methods.
Resumo:
The aim of this study was to compare the hydrographically conditioned digital elevation models (HCDEMs) generated from data of VNIR (Visible Near Infrared) sensor of ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer), of SRTM (Shuttle Radar Topography Mission) and topographical maps from IBGE in a scale of 1:50,000, processed in the Geographical Information System (GIS), aiming the morphometric characterization of watersheds. It was taken as basis the Sub-basin of São Bartolomeu River, obtaining morphometric characteristics from HCDEMs. Root Mean Square Error (RMSE) and cross validation were the statistics indexes used to evaluate the quality of HCDEMs. The percentage differences in the morphometric parameters obtained from these three different data sets were less than 10%, except for the mean slope (21%). In general, it was observed a good agreement between HCDEMs generated from remote sensing data and IBGE maps. The result of HCDEM ASTER was slightly higher than that from HCDEM SRTM. The HCDEM ASTER was more accurate than the HCDEM SRTM in basins with high altitudes and rugged terrain, by presenting frequency altimetry nearest to HCDEM IBGE, considered standard in this study.