166 resultados para Aqueous Extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A RP-HPLC procedure for the simultaneous determination of cisplatin and the complex cis,cis,trans-diamminedichlorodihydroxo-platinum(IV), was development. The developed procedure was validated in terms of linearity, accuracy, precision, limits of detection (LOD), limits of quantification (LOQ) and specificity. The limits of detection (LOD) were 0.47 x 10-4 and 0.53 x 10-4 mol L-1 and the limits of quantification (LOQ) were 1.57 x 10-4 and 1.75 x 10-4 mol L-1, for cisplatin and cis,cis,trans-diamminedichlorodihydroxopla-tinum(IV), respectively. The average recoveries of cisplatin and cis,cis,trans-diamminedichlorodihydroxoplatinum(IV) was 100.6% ± 1.4 and 101.2% ± 1.1, respectively. Intermediate (inter-day) precision, repeatability and specificity of the procedure for hydrolysis products of cisplatin were studied. The results of the study showed that the proposed RP-HPLC procedure is simple, rapid, precise, accurate and specific.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extraction of divalent metals (Mn2+, Ni2+, Co2+ and Cu2+) in the system MSO4 - H2SO4 - H2O - D2EHPA in isoparaffin (17/21) was studied by a thermodynamic model based on chemical equilibria with mass and charge balance equations. The activity coefficients of all solutes in the aqueous phase were calculated by Davies equation. By applying this model, the equilibrium concentrations of solutes were calculated from de concentration of divalent metals and pH. The predicted distribution coefficients for the divalents metals were in good agreement with experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supercritical fluid extraction was used to extract active compounds from the Chinese traditional medicinal D. dasycarpus under the pressure of 30 MPa and temperature of 45 ºC. Further separation and purification was established by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (1:0.8:1.3:0.9, volume ratio). The separation yielded a total of 47 mg of dictamnine, 24 mg of obacunone and 83 mg of fraxinellone from 1.0 g of the crude extract in one step separation with the purity of 99.2, 98.4 and 99.0%, respectively, as determined by HPLC. The chemical structures of these compounds were identified by ESI-MS, IR, ¹H-NMR and 13C-NMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using HPTLC for quantitation of nifedipine in serum was developed and validated. It includes a liquid-liquid extraction, and carbamazepine as internal standard. Chloroform: ethyl acetate: cyclohexane (19:2:2, v/v/v) was the mobile phase. The method showed good relationship (r = 0.996) (2.00 to 25.00 ng/band, corresponding to 0.02 and 0.25 ng/µL in serum). The % RSD of intra-assay and inter-assay, were between 0.57 and 3.56 and 1.16 to 3.60, respectively. LOD and LOQ were 0.72 and 0.86 ng/band, respectively. The recovery values were between 93 and 102%. Rf for nifedipine and carbamazepine were 0.31 and 0.10, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new sensitive and selective procedure for speciation of trace dissolved Fe(III) and Fe(II), using modified octadecyl silica membrane disks and determination by flame atomic absorption spectrometry was developed. A ML3 complex is formed between the ligand and Fe(III) responsible for extraction of metal ion on the disk. Various factors influencing the separation of iron were investigated and the optimized operation conditions were established. Under optimum conditions, an enrichment factor of 166 was obtained for Fe3+ ions. The calibration graph using the preconcentration system for Fe3+ was linear between 40.0 and 1000.0 μg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyclosporine-A-loaded PLGA implants were developed intended for ocular route. Implants were prepared using solvent extraction/evaporation technique followed by casting of the cake into rods in a heated surface. XRD patterns showed that cyclosporine-A was completely incorporated into PLGA. FTIR and DSC results indicated alterations on drug molecular conformation aiming to reach the most stable thermodynamic conformation at polymer/drug interface. Implants provided controlled/sustained in vitro release of the drug. During the first 7 weeks, the drug release was controlled by the diffusion of the cyclosporine-A; and between 7-23 week period, the drug diffusion and degradation of PLGA controlled the drug release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 1µs Molecular Dynamic simulation was performed with a realistic model system of Sodium Dodecyl Sulfate (SDS) micelles in aqueous solution, comprising of 360 DS-, 360 Na+ and 90000 water particles. After 300 ns three different micellar shapes and sizes 41, 68 and 95 monomers, were observed. The process led to stabilization in the total number of SDS clusters and an increase in the micellar radius to 2.23 nm, in agreement with experimental results. An important conclusion, is be aware that simulations employed in one aggregate, should be considered as a constraint. Size and shape distribution must be analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and efficient method has been developed and validated for the determination of fipronil in bovine plasma. Samples were subjected to solid-phase extraction (SPE) followed by reversed phase liquid chromatography (LC) separation, using acetonitrile/water (60:40 v/v) as the mobile phase with a flow rate of 1.0 mL/min and ultraviolet (UV) detection at 210 nm. Ethiprole was used as the internal standard (IS). The method was found to be linear over the range 5-500 ng/mL (r = 0.999). The limit of quantitation (LOQ) was validated at 5 ng/mL. The method was successfully applied to monitor plasma concentrations following subcutaneous administration of fipronil in cattle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new cloud point extraction (CPE) method was developed for the separation and preconcentration of copper (II) prior to spectrophotometric analysis. For this purpose, 1-(2,4-dimethylphenyl) azonapthalen-2-ol (Sudan II) was used as a chelating agent and the solution pH was adjusted to 10.0 with borate buffer. Polyethylene glycol tert-octylphenyl ether (Triton X-114) was used as an extracting agent in the presence of sodium dodecylsulphate (SDS). After phase separation, based on the cloud point of the mixture, the surfactant-rich phase was diluted with acetone, and the enriched analyte was spectrophotometrically determined at 537 nm. The variables affecting CPE efficiency were optimized. The calibration curve was linear within the range 0.285-20 µg L-1 with a detection limit of 0.085 µg L-1. The method was successfully applied to the quantification of copper in different beverage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the use of potentiometric measurements for kinetic studies of biosorption of Cd2+ ions from aqueous solutions on Eichhornia crassipes roots. The open circuit potential of the Cd/Cd2+ electrode of the first kind was measured during the bioadsorption process. The amount of Cd2+ ions accumulated was determined in real time. The data were fit to different models, with the pseudo-second-order model proving to be the best in describing the data. The advantages and limitations of the methodology proposed relative to the traditional method are discussed.