87 resultados para 671402 Medical instrumentation
Resumo:
OBJECTIVE: to compare the knowledge of medical students between those who are members of the Trauma League (TL) and those from a non-Trauma League (NTL) group of the Federal University of Espírito Santo (UFES).METHODS: cross-sectional, analytical and descriptive study. Two knowledge tests, with 30 questions each, were applied to students from 3rd to 12th period, randomly selecting five students per period, with 50 students in the TL group and 50 in NTL. The questionnaire topics were: pre-hospital care, the mnemonic ABCDE trauma sequence, advanced trauma and imaging. The students' performances were evaluated by graduation-period group: basic (3rd-5th period), intermediary/clinical (6th-8th) and internship (9th-12th).RESULTS: in the first test the average accuracy of the TL group was 20.64 ± 3.17, while for the NTL group, it was 14.76 ± 5.28 (p<0.005). In the second test the average accuracy for the TL group was 21.52 ± 3.64, while for the NTL group, the average was 15.36 ± 29.5 (p<0.005). When divided into graduation periods, it was observed that the TL group showed a higher average across all three groups (p<0.05) in both tests.CONCLUSION: the students who attended the academic league activities have greater knowledge of the issues that are considered relevant to patient trauma care. In all periods of undergraduate academic training, the TL group had greater knowledge of the subject than the NTL group.
Resumo:
Medical students must have domain of basic surgery skills before starting more advanced stages of surgical learning. The authors present a practical and reproducible system of operative techniques circuit, idealized and often applied to the fourth year medical students of a private educational institution. This method has enabled accurate assessment of students' skills, improving their performance and preparing them for more advanced stages of the surgical learning.
Resumo:
Standard techniques for radioautography used in biological and medical research can be classified into three categories, i.e., macroscopic radioautography, light microscopic radioautography and electron microscopic radioautography. The routine techniques used in these three procedures are described. With regard to macroscopic radioautography, whole body radioautography is a standard technique which employs freezing and cryosectioning and can demonstrate organ distributions of both soluble and insoluble compounds. In contrast, in light and electron microscopic radioautography, soluble and insoluble techniques are separated. In order to demonstrate insoluble labeled compounds, conventional chemical fixations such as formalin for light microscopy or buffered glutaraldehyde and osmium tetroxide for both light and electron microscopy followed by dehydration, embedding and wet-mounting applications of radioautographic emulsions can be used. For the demonstration of soluble labeled compounds, however, cryotechniques such as cryofixation, cryosectioning, freeze-drying, freeze-substitution followed by dry-sectioning and dry-mounting radioautography should be employed both for light and electron microscopy. The outlines of these techniques, which should be utilized in various fields of biological and medical research, are described in detail
Resumo:
A new concept in the therapy of both neoplastic and non-neoplastic diseases is discussed in this article. Photodynamic therapy (PDT) involves light activation, in the presence of molecular oxygen, of certain dyes that are taken up by the target tissue. These dyes are termed photosensitizers. The mechanism of interaction of the photosensitizers and light is discussed, along with the effects produced in the target tissue. The present status of clinical PDT is discussed along with the newer photosensitizers being used and their clinical roles. Despite the promising results from earlier clinical trials of PDT, considerable additional work is needed to bring this new modality of treatment into modern clinical practice. Improvements in the area of light source delivery, light dosimetry and the computation of models of treatment are necessary to standardize treatments and ensure proper treatment delivery. Finally, quality assurance issues in the treatment process should be introduced.
Resumo:
The sleep-wake cycle of students is characterized by delayed onset, partial sleep deprivation and poor sleep quality. Like other circadian rhythms, the sleep-wake cycle is influenced by endogenous and environmental factors. The aim of the present study was to determine the effects of different class starting times on the sleep-wake pattern of 27 medical students. The data were collected during two medical school semesters having different class starting times. All subjects answered the Portuguese version of the Horne and Östberg Morningness/Eveningness Questionnaire, the Pittsburgh Sleep Quality Index (PSQI) and kept a sleep diary for two weeks during each semester. Better sleep quality (PSQI = 5.3 vs 3.4), delayed sleep onset (23:59 vs 0:54 h) and longer sleep duration (6 h and 55 min vs 7 h and 25 min) were observed with the late schedule. We also found reduced sleep durations during weekdays and extended sleep durations during weekends. This pattern was more pronounced during the semester with the early class schedule, indicating that the students were more sleep deprived when their classes began earlier in the morning. These results require further investigation regarding the temporal organization of our institutions.
Resumo:
In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia) and higher order aberrations (coma, spherical aberration, etc.). We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS) sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE) of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.
Resumo:
Shape memory alloys (SMA) are materials that have the ability to return to a former shape when subjected to an appropriate thermomechanical procedure. Pseudoelastic and shape memory effects are some of the behaviors presented by these alloys. The unique properties concerning these alloys have encouraged many investigators to look for applications of SMA in different fields of human knowledge. The purpose of this review article is to present a brief discussion of the thermomechanical behavior of SMA and to describe their most promising applications in the biomedical area. These include cardiovascular and orthopedic uses, and surgical instruments.
Resumo:
Today, the quality of a scientific article depends on the periodical in which it is published and on the number of times the article is cited in the literature. In Brazil, the criteria for the evaluation of this scientific production are improving. However, there is still some resistance, with authors arguing that Brazilian publications must be preferentially addressed to the national readers and, therefore, they should ideally be written in Portuguese. In order to determine the kind of scientific journals cited in the reference lists of articles published in medical periodicals edited in Brazil, in the present study we determine the rate of Portuguese/English citations. Three issues of 43 periodicals (19 indexed in SciELO, 10 in PubMed, 10 in LILACS, and 4 in the ISI-Thompson base) of different medical specialties were analyzed, and the number of both Portuguese and English citations in the reference list of each article was recorded. The results showed that in Brazilian-edited journals the mean number of citations/article was 20.9 ± 6.9 and the percentage of citations of international non-Brazilian periodicals was 86.0 ± 11.2%. Of the latter, 94.4 ± 7.0 are indexed by ISI-Thompson. Therefore, we conclude that Brazilian medical scientists cite the international non-Brazilian periodicals more than the national journals, and most of the cited papers are indexed by ISI-Thompson.
Resumo:
The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.