429 resultados para quantificação
Resumo:
Least-squares support vector machines (LS-SVM) were used as an alternative multivariate calibration method for the simultaneous quantification of some common adulterants found in powdered milk samples, using near-infrared spectroscopy. Excellent models were built using LS-SVM for determining R², RMSECV and RMSEP values. LS-SVMs show superior performance for quantifying starch, whey and sucrose in powdered milk samples in relation to PLSR. This study shows that it is possible to determine precisely the amount of one and two common adulterants simultaneously in powdered milk samples using LS-SVM and NIR spectra.
Resumo:
Solid dextrans are thermally stable polysaccharides losing water only at 160ºC. According to IR, X-ray, DTA and DSC data no noticeable changes in dextran configuration occurs at this temperature. The total content of dextrans analyzed in 26 samples of Brazilian sugars and 57 samples of sweetened cachaças ranged from 109.5 to 1840 mg/kg and 1.6 to 11.2 mg/L with medians of 999.8 mg/kg and 5.9 mg/L respectively. Samples of sweeted cachaças have been monitored for turbidity, total soluble dextran content and weight of precipitate formed during 275 days. Precipitate formation is a kinetically controlled process which ends after 275 days when the total concentration of soluble dextrans becomes smaller than 0.25 mg/L.
Resumo:
The solubility of Mn in different fertilizers (MnSO4.H2O-p.a., MnO2-p.a.+MnO-Ind., MnO2-Ind.+MnO-Ind., MnO2-p.a., MnO2-Ind. and MnO-Ind.) was determined using different methodologies: total content and soluble contents in water, 10% H2SO4, citric acid at 20 g L-1, diluted neutral ammonium citrate, (1+9) and DTPA at 0.005 mol L-1. The Mn solubilities in the latter three extractors were assessed after agitation of the sample for one hour and after boiling for 5 minutes. The extraction procedure using neutral ammonium citrate (1+9), at 1:100, with agitation for one hour, was shown to be the most adequate to assess the availability of Mn in fertilizers.
Resumo:
Sunflower oil is one of the vegetable oils most susceptible to oxidative reaction. Therefore the presence of natural (tocopherol) and/or synthetic (TBHQ) antioxidants is a prerequisite to secure the stability of this oil during its shelf life, especially with the increased use of PET packaging. On determining the total tocopherol content in 10 samples of deodorized sunflower oils, high losses in total tocopherol during deodorization were identified. In order to facilitate researche involving oxidative stability of vegetable oils, a method for isolated quantification of TBHQ using the isocratic elution system was developed.
Resumo:
Biological monitoring is very important to guarantee health to workers. This method was developed for simultaneous determination of xylene, toluene, styrene and ethylbenzene metabolites. It involves only dilution and centrifugation of urine samples and improved chromatographic conditions. Analyses show recovery > 95%; r² > 0.99; intermediate precision CV% < 6% and % bias < ±10. Exposed subjects presented at least three metabolites in urine. The method proved to be feasible, reliable and important in biological monitoring, especially in exposure to organic solvent mixtures.
Resumo:
Bupivacaine (S75-R25, NovaBupi®) is an amide type local anesthetic widely used. The present work consists of the development and validation of analytical methodology for evaluation of NovaBupi® content in the poly-lactide-co-glycolide nanospheres (PLGA-NS) by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/phosphate buffer 85:15 v/v as mobile phase and detection at 220 nm. The results obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 10-220.0 g/mL of NovaBupi®. The method was applied to determine the encapsulation efficiency and evaluate the release profile of NovaBupi®, showing good results.
Resumo:
The lack of accuracy of a chromatographic method can be associated with the matrix effect. This effect is observed in pesticide quantification by gas chromatography when the chromatographic signals of standards prepared in solvents are compared with those of the analyte in extracts of complex matrices. In the competition between the matrix components and the pesticides for the active sites of the liner, a larger amount of pesticides is transferred to the column, giving apparent extractions above 100%. In this work, we discuss factors that contribute to the matrix effect and present some attempts to overcome the problem.
Resumo:
This article describes an experiment designed to teach quantitative determination in gas chromatography (GC) in Organic and Analytical Chemistry practical classes. The experiment consisted of extracting and analyzing eugenol from clove seeds to perform a quantitative approach aimed at comparing results obtained by external and internal calibration procedures. Therefore, this experiment proved to be very effective tool to enhance students awareness on the need to understand different types of calibration in GC and on how to avoid common experimental errors, and to find the best ways to eliminate their interference during the quantitative analysis phase.
Resumo:
This paper reports the use of Raman and infrared techniques for the qualitative and quantitative analysis of plasticizers in polyvinylchloride (PVC) commercial films. FT-Raman marker bands were indentified for di-2-ethyl-hexyl adipate (DEHA) and di-2-ethyl-hexyl phthalate (DEHP), allowing for the rapid identification of these species in the commercial film. Quantitative analysis by FT-IR resulted in plasticizers concentrations ranging from 11 to 27% (w/w). Considering the little sample preparation and the low cost of the techniques, FT-IR and FT-Raman are viable techniques for a first assessment of plasticizers in commercial samples.
Resumo:
A phenolic fraction was obtained from of the acetone-water-acetic acid extract of Inga edulis leaves, by liquid-liquid partition and SPE-C18 cartridges. This method provided an increase of 108, 66, 51, 50 and 36% of flavonols, proanthocyanidins, total polyphenols, gallotannins and flavanols, respectively. The major phenolics in purified fraction were procyanidin B2, catechin and myricetin-3-O-α-L-rhamnopyranoside, which achieved increases of 111, 47 and 45%, respectively, after SPE. Acid hydrolysis confirmed the presence of procyanidins, prodelphinidins and glycosylated flavonoids.
Resumo:
In this work was studied composts and their humic acids (HA) to evaluate the use of EPR in the monitoring of the humification. It was observed increase in the concentration of organic free radical (OFR) in all the composts, but in L1 the increase was more significant than L2 and L3. Research more detailed of L1 showed that the lignin is main source of OFR. Then determination of these radicals in material in nature that contains high amount of lignin isn't a good indicator to monitor the humification process in the composting and yes the fraction HA of the composts.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.
Resumo:
Pulp hemicelluloses can be extracted with NaOH and quantified by colorimetric and gravimetric techniques. However the most usual methods to measure eucalyptus pulp hemicelluloses have been through the pentosan method or through xylan analyses by GC or HPLC techniques. In this study a comparison was made between the more traditional methods and indirect method of NaOH 5% extraction followed by colorimetric analyses. It was observed that the content of NaOH 5% extract correlates very well with pulp xylan content and reasonably well with the pentosan content. It is concluded that the 5% NaOH solubility method can be used in replacement of the other two, since it is faster, simpler and less costly to carry out than the others.
Resumo:
The measurement uncertainty is useful to estimate the confidence of analytical results. Nowadays, a result without the uncertainty statement cannot be considered reliable, but the scientific literature still lacks examples of the estimate of the measurement uncertainty. This paper presents a practical and reliable description of the measurement uncertainty estimation of the analytical determination of ethyl carbamate in cachaça by GC-IDMS. The isotope dilution technique (ID) associated with GC-MS was used to improve the accuracy. The uncertainty estimated corresponds to 10% of the mass fraction of ethyl carbamate (115 ± 11) ng/g, which is in agreement with ppb level.
Validação de método espectrofotométrico na região do UV para quantificação de famotidina em cápsulas
Resumo:
This work describes the validation of a method for quantification of famotidine in capsules by UV spectrophotometry using as solvents buffer solution at pH 2.5 and buffer solution at pH 4.5. The results show that the method is practical, selective, accurate, precise and linear from 10.0 to 25.0 µg/mL of famotidine in both solvents. However, a variance analysis showed a lower mean percentage of famotidine when buffer at pH 2.5 is used. This effect was attributed to the instability of famotidine in acidic media. Therefore, the use of pH 4.5 buffer was considered suitable for analysis of famotidine in capsules.