153 resultados para SPE-HLLME-GS-MS
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.
Resumo:
A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.
Resumo:
The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.
Resumo:
The word gas was coined by the "chemical philosopher" Joan Baptista Van Helmont (1579 -- 1644) to name a very broad concept in his chemico-medical system. Eventually, some physicians who followed Helmontian ideas adopted the concept. The present paper aims to analyze the reception of the original idea of gas by an English Helmontian physician, George Thomson (1619 -- 1677). Thomson wrote that the "material cause" of the plague was a gas, and compared it to the "Gas of sulphur". He also related the human archeus to a gas, and explained some observations in the laboratory in terms of production of gases. We observe, however, that Thomson was not as interested as Van Helmont in discussing details about the structure of the matter. Thus, gas did not have the same relevance in Thomson's work as it had in Van Helmont's.
Resumo:
The main purpose of this work was the qualitative study of organic compounds in landfill leachate. The samples were collected from a sanitary landfill located at Gravataí, a southern Brazilian city, that receive both, industrial and domestic refuse. The samples were submitted to solid phase extraction (SPE) with XAD-4 resin as the stationary phase. The instrumental analysis was performed by Gas Chromatography with a Mass Spectrometry Detector (GC/MSD). The compounds achieved in the SPE extracts were tentatively identified by the GC/MS library. It was found several oxygen and nitrogen compounds like carboxylic acids, ketones, amines and amides. Sulfur compounds and phthalate esters are also identified.
Resumo:
Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.
Resumo:
This paper focuses on the early interpretations of the concept of gas, originally created by J. B. Van Helmont (1579 ¾ 1644). Our main interest is on the ideas of English physicians and chemical philosophers of the seventeenth century. Gas was usually associated with the material cause of diseases, with the vital spirit, or with a volatile spirit produced in some kinds of material transformations. As a general trend, however, the authors who did not want to embrace the details of the medico-chemical system proposed by Van Helmont preferred to use more well-known words (such as vapours, exhalations, effluvia, odours, spirits), avoiding the use of the neologism.
Resumo:
This note has as objective to present the advantages of the use of syringe-type pumps for the feeding of liquid reactants, together with mass flow controllers for gases, instead of the saturators, as it is generally accomplished. Among the advantages, the system with syringe pumps presents a greater flexibility in flow control as well as in composition compared with the system that uses saturator. In addition, the flow of the liquid reactants is known with precision in the syringe pump system.
Resumo:
A new extraction method for sterols was tested in fruits of Ottonia martiana Miq., a shrub belonging to the family Piperaceae, popularly known as "anestésica" due to the use of its roots and aerial parts, in alcoholic preparations, in treatment of odontological problems. For this purpose, a portable extraction equipment was developed, to operate with liquified gases, which showed to be practical, fast and effective, besides being economical and ecological. In the chromatographic analysis of the extracts obtained in this equipment, it was demonstrated the presence of two sterols, isomers of b-sitosterol and stigmasterol.
Resumo:
Solid phase extraction (SPE) in C18 disks has been optimized and validated for extraction of 5 organophosphorus (OP) pesticides in water. Extraction has been followed by separation and detection by gas chromatography/flame photometry. Excellent linearity was obtained for all compounds (r greater than 0.99), with CVs between 1.0-6.9%, recoveries between 73-95% and quantification limits between 2.5-5.0 µg L-1. Samples from Furnas dam were analyzed monthly during one year and 10% showed OP pesticide residues.
Resumo:
Nitrogen content in natural gas was studied in experimental and computational investigations to identify its influence on the emission level of exhaust gases from combustion facilities. Changes in natural gas composition with different N2 concentrations may result from introducing a new source gas into the system. An industrial burner fired at 75 kW, housed in a laboratory-scale furnace, was employed for runs where the natural gas/N2 proportion was varied. The exhaust and in-furnace measurements of temperature and gas concentrations were performed for different combustion scenarios, varying N2 content from 1-10 %v. Results have shown that the contamination of natural gas with nitrogen reduced the peak flame temperature, the concentration of unstable species, the NO X emission level and the heat transfer rate to the furnace walls, resulting from the recombination reactions.
Resumo:
LaNiO3 perovskite was modified by partial substitution of nickel by cobalt in order to increase the stability and resistance to carbon deposition during the methane CO2 reforming. The results showed that a suitable combination of precipitation and calcination steps resulted in oxides with the desired structure and with important properties for application in heterogeneous catalysis. The partial substitution of Ni by Co resulted in lower rates of conversion of both the reactants, but the catalyst stability was highly increased. The LaNi0.3Co0.7O3 catalyst, calcined at 800 ºC, was the most active under the reaction conditions.
Resumo:
Increasing natural gas use in Brazil triggered a discussion of its role as a Hg source. We show that Hg emissions to the atmosphere from fossil fuel combustion for power generation in Brazil contribute with 6.2% (4.2 t yr-1) to the total anthropogenic Hg atmospheric emissions, with coal combustion and biomass burning as major sources. Natural gas contributes with 0.04 t yr-1, mostly from electricity generation (88%) and industrial uses (7.6%). Preliminary results on Hg concentrations in natural gas suggest that a large fraction of it is trapped during refining and transport, which may create Hg point sources between extraction and consumption.
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) are a great environmental concern mainly because of their toxic, mutagenic and carcinogenic potential. This paper reports utilization of the solid-phase extraction (SPE) technique to determine PAHs in environmental aqueous matrices. The recovery from environmental aqueous matrices fortified with PAHs varied from 63.7 to 93.1% for atmospheric liquid precipitation, from 38.3 to 95.1% for superficial river water, and from 71.0 to 95.5% for marine water. No negative matrix effect was observed for the recovery of PAHs from atmospheric liquid precipitation and marine water, but was observed for superficial river water, particularly for PAHs possessing 5 and 6 aromatic rings.