143 resultados para Plaletet-Rich Plasma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic diversity displayed by Plasmodium falciparum, the most deadly Plasmodium species, is a significant obstacle for effective malaria vaccine development. In this study, we identified genetic polymorphisms in P. falciparum glutamate-rich protein (GLURP), which is currently being tested in clinical trials as a malaria vaccine candidate, from isolates found circulating in the Brazilian Amazon at variable transmission levels. The study was performed using samples collected in 1993 and 2008 from rural villages situated near Porto Velho, in the state of Rondônia. DNA was extracted from 126 P. falciparum-positive thick blood smears using the phenol-chloroform method and subjected to a nested polymerase chain reaction protocol with specific primers against two immunodominant regions of GLURP, R0 and R2. Only one R0 fragment and four variants of the R2 fragment were detected. No differences were observed between the two time points with regard to the frequencies of the fragment variants. Mixed infections were uncommon. Our results demonstrate conservation of GLURP-R0 and limited polymorphic variation of GLURP-R2 in P. falciparum isolates from individuals living in Porto Velho. This is an important finding, as genetic polymorphisms in B and T-cell epitopes could have implications for the immunological properties of the antigen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram analisadas a composição e sazonalidade da comunidade de lepidópteros visitantes florais de S. cayennensis na Estação Ambiental de Peti. Registrou-se a visita de 445 lepidópteros pertencentes a 98 espécies, distribuídos em 6 famílias: Hesperiidae (81,8%), Pieridae (10,8%), Lycaenidae (3,6%), Nymphalidae (2,2%), Papilionidae (1,3%) e Sesiidae (0,3%). Os hesperídeos também apresentaram a maior riqueza, com 70 espécies amostradas. Das espécies amostradas, apenas quatro tiveram abundância relativa acima de 5% (Pyrgus orcus (Stoll, 1780), Pompeius pompeius (Latreille, [1824]), Urbanus dorantes dorantes (Stoll, 1790) e Corticea corticea (Plötz, 1882)). De acordo com a classificação de Palma, duas espécies foram comuns, 12 intermediárias e 84 foram consideradas raras. Os valores de diversidade e uniformidade foram altos (H'= 3,98 e E = 0,87). Existe nítida diferença na composição e abundância das espécies ao longo do ano, onde foi observado que a maior riqueza de espécies e número de indivíduos estiveram concentrados na estação chuvosa. A similaridade entre as duas estações foi relativamente baixa, 25 ocorreram na estação seca, 93 na chuvosa e apenas 18 ocorreram nas duas estações. Os lepidópteros apresentaram maior atividade de forrageamento em temperaturas entre 23 e 32 ºC, sendo a maior abundância registradas por volta das 10:00 horas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maghemite (γFe2O3) from tuffite is exceptionally rich in Mg, relatively to most of those reportedly found in other mafic lithosystems. To investigate in detail the compositional and structural variabilities of this natural magnetic iron oxide, sets of crystals were isolated from samples collected at different positions in a tuffite weathering mantle. These sets of crystal were individually powdered and studied by X-ray diffractometry, Mössbauer spectroscopy, magnetization measurements and chemical analysis. Lattice parameter of the cubic cell (a0) was found to vary from 0.834(1) to 0.8412(1) nm. Lower a0-values are characteristic of maghemite whereas higher ones are related to a magnetite precursor. FeO content ranges up to 17 mass % and spontaneous magnetization ranges from 8 to 32 J T-1 kg-1. Zero-field room temperature Mössbauer spectra are rather complex, indicating that the hyperfine field distributions due to Fe3+ and mixed valence Fe3+/2+ overlap. The structural variabilities of the (Mg, Ti)-rich iron oxide spinels is essentially related to the range of chemical composition of its precursor (Mg, Ti)-rich magnetite, and probably to the extent to which it has been oxidized during transformation in soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para aumentar a precisão nas análises químicas de fertilidade do solo e dosar simultaneamente vários elementos, alguns laboratórios vêm optando pelo uso da técnica da espectrofotometria de emissão ótica em plasma induzido (ICP), em detrimento da técnica da espectrofotometria de absorção atômica (EAA), hoje comumente utilizada nos laboratórios de análise de solos. Este trabalho, além de comparar as duas técnicas de dosagem quanto à precisão, à reprodutibilidade e à magnitude dos teores dos micronutrientes Fe, Zn, Cu e Mn, extraídos por Mehlich-1, Mehlich-3 e DTPA-TEA, objetivou, também, selecionar os comprimentos de onda que apresentam menores interferências espectrais no ICP. Foram utilizadas 36 amostras (0 a 0,2 m) de solos coletadas nos Estados de Minas Gerais e Bahia, com ampla variação nos teores de micronutrientes, sendo selecionados três solos para definir os comprimentos de onda do ICP e avaliar a precisão e a reprodutibilidade dos métodos de dosagem. Os comprimentos de onda com menores interferências espectrais no ICP foram: 259,939 nm para Fe em Mehlich-1 e DTPA-TEA e 234,349 nm em Mehlich-3; 213,857 nm para Zn e 324,752 nm para Cu nos três extratores; e 259,372 nm para Mn em Mehlich-1 e DTPA-TEA e 260,568 nm em Mehlich-3. Tanto o ICP quanto o EAA foram precisos e reprodutíveis nas dosagens de Fe e Mn, sendo o ICP, em virtude do seu menor limite de detecção, mais preciso e reprodutível nas dosagens de Zn e Cu. Os métodos de dosagem diferiram estatisticamente (p < 0,01) pelo teste de identidade aplicado, para as dosagens de Fe, Zn, Cu e Mn, utilizando Mehlich-1, Mehlich-3 e DTPA-TEA, comprometendo assim a interpretação dos resultados gerados pelo ICP, com base nos níveis críticos gerados a partir do EAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effect of photoperiod on luteinizing hormone (LH) plasma levels and gonadal maturation of lambari females. One hundred and twenty adult lambaris, distributed into 12 aquaria of 20 L each, were randomly subjected to three different treatments, in a completely randomized design, and four replicates. Treatments were photoperiods in hours of light (L) and darkness (D): T1, 0 L:24 D; T2, 12 L:12 D; T3, 24 L:0 D. After 40 days, fish were subjected to fasting for 24 hours and, then, anesthetized. Immediately after slaughter, fish were weighed, and their gonads and livers were removed and weighed. Ovaries were weighed and immersed in Bouin's fixative solution for 24 hours and, then, kept in 70% alcohol until processing the material. Subsequently, the oocyte developmental stage was determined. No significant differences were observed between treatments for final weight, ovary weight, gonadosomatic index (GSI), hepatosomatic index (HSI) and LH levels. In all treatments, lambari females showed maturing ovaries with prevalence of vitellogenic oocytes. Photoperiod does not affect the LH levels and ovarian maturation in lambari females.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A column packed with 5-(4-dimethylaminobenzylidene)rhodanine adsorbed on silica gel was used for the preconcentration of Cd, Ni and Zn at different spiked solutions prior to their determination by inductively coupled plasma atomic emission spectrometry. This column allowed recoveries over than 98% for the above elements and accurate analyses of coastal sea-water certified reference material were also achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead absorption is influenced by the species that are formed and the physicochemical characteristics of lead, among others. Lead plasma concentration is < 5% of total blood lead and represents the biologically active fraction able to cross the cell membranes. Health risks mainly depend on a specific metal and its species. Speciation analysis is the analytical activity of identifying and determining different metal species. Chromatographic methods are very useful in the identification of species and the techniques most used to determine metals in biological fluids are ICP OES/MS and AAS. Lead speciation analysis in blood plasma is fundamental for understanding and evaluating the interaction mechanisms between that analyte and its biological targets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.