117 resultados para Liquid chromatography-diode array detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, RP-HPLC method was established for determining moxifloxacin and ketorolac in pharmaceutical formulations. Moxifloxacin, ketorolac and their degradation products were separated using C8 column with methanol and phosphate buffer pH 3.0 (55:45 v/v) as the mobile phase. Detection was performed at 243 nm using a diode array detector. The method was validated using ICH guidelines and was linear in the range 20-140 µg mL-1 for both analytes. Good separation of both the analytes and their degradation products was achieved using this method. The developed method can be applied successfully for the determination of moxifloxacin and ketorolac.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quantitative chemical analysis of the Brazilian sugar cane spirit distilled from glass column packaged with copper, stainless steel, aluminum sponge, or porcelain balls is described. The main chemical compounds determined by gas chromatography coupled with flame ionization (FID) and flame photometric (FPD) detectors and liquid chromatography coupled with diode array detector are aldehydes, ketones, carboxylic acids, alcohols, esters and dimethylsulfite (DMS). The spirits produced either in columns filled with copper or aluminum pot still exhibits the lowest DMS contents but the higher sulfate and methanol contents, whereas spirits produced in stainless steel or porcelain showed higher DMS concentration and lower teors of sulfate ion and methanol. These observations are coherent with DMS oxidation to sulfate, with methanol as by product, in the presence of either copper or aluminum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for quantifying urinary 2,5-hexanedione was optimized and validated. Urine samples were hydrolyzed and derivatized with 2,4-dinitrophenylhydrazine. The analyte was separated in a high performance liquid chromatography system with a diode array detector, using a C18 column (150 x 4.6 mm, p.d. 5 µm) and a mobile phase composed of phosphate buffer pH 2.3:acetonitrile (40:60, v/v), at a flow rate of 1 mL/min. The chromatograms were monitored at 334 nm. Retention time was 7.3 minutes. Main validation parameters were: coefficient of determination: 0.9994, accuracy: 96 to 107%; intra-assay precision (RSD): 3.08 to 6.72%; inter-assay precision (RSD): 2.54 to 8.17% and limit of quantitation of 0.19 µg/mL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chemical stability of enalapril drug substance and tablets was studied by a stability-indicating liquid chromatographic method. Stress testing was performed on drug substance under various conditions. Accelerated stability testing was carried out for different formulations of enalapril tablets. Chromatographic separation was achieved on a RP-18 column, using a mobile phase of methanol phosphate buffer at 1.0 mL min"1 and UV detection. Degradation of the drug substance was greater under hydrolytic conditions. After 180 days of accelerated stability testing most enalapril tablets showed more than 10% of degradation. Enalapril drug substance and tablets showed instability under stress and accelerated testing respectively, with possible implications on the therapeutic activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phenylpropanoid glycoside verbascoside was isolated and identified from the ethyl acetate fraction of the aerial parts of Buddleja stachyoides Cham. & Schltdl. by 1H-NMR. A method using high-performance liquid chromatography has been developed and validated for determination of verbascoside in alcoholic crude extract of the aerial parts of B. stachyoides. Analysis was performed on a Phenomenex® Gemini-NX C18 analytical column (250 mm × 4.6 mm; 5 µm) using a mobile phase (pump A - aqueous solution containing H2SO4 (0.01 M), H3PO4 (0.4%), and (C2H5)2NH (0.4%); pump B - methanol:aqueous (95:5) solution containing H2SO4 (0.05 M), H3PO4 (2%), and (C2H5)2NH (0.2%); pump C - acetonitrile:aqueous (90:10) solution containing H2SO4 (0.05 M) and H3PO4 (2%)) and a diode array detector at 325 nm. The method was validated in accordance with ANVISA guidelines and may be applied to quality control of herbal medicine with aerial parts of B. stachyoides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple procedure based on stir bar sorptive extraction and high-performance liquid chromatography-ultraviolet/photodiode array detection (SBSE/LC-UV/PAD) to determine intermediates and by-products of esfenvalerate is described. The influence of organic modifier, ionic strength, extraction time, temperature and pH were simultaneously evaluated by using a factorial experimental design. The utilization of different organic solvents and desorption times were also investigated to establish the optimal conditions for SBSE liquid desorption. Among the ten different peaks (intermediates and by-products) detected after degradation of esfenvalerate, eight (including 3-phenoxybenzoic acid and 3-phenoxybenzaldehyde) were successfully extracted by SBSE under the optimized conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the reductive degradation of acetamiprid (5 mg L-1) in aqueous medium (at pH 2.0) induced by zero-valent iron (50 mg). The process was monitored using high-performance liquid chromatography (HPLC) to determine the degradation rate as a function of reaction time, and direct infusion electrospray ionization mass spectrometry (DI-ESI-MS) to search for (and potentially characterize) any possible byproducts formed during degradation. The results obtained via HPLC showed that after 60 min, the degradation of the substrate reached nearly 100% in an acidic medium, whereas the mineralization rate (as determined by total organic carbon measurements) was as low as 3%. Data obtained by DI-ESI-MS showed that byproducts were formed mainly by insertions of hydrogen atoms into the nitrile, imine, and pyridine ring moieties, in addition to the observation of chlorine substitution by hydrogen replacement (hydrodechlorination) reactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A better method for determination of shikimate in plant tissues is needed to monitor exposure of plants to the herbicide glyphosate [N-(phosphonomethyl)glycine] and to screen the plant kingdom for high levels of this valuable phytochemical precursor to the pharmaceutical oseltamivir. A simple, rapid, and efficient method using microwave-assisted extraction (MWAE) with water as the extraction solvent was developed for the determination of shikimic acid in plant tissues. High performance liquid chromatography was used for the separation of shikimic acid, and chromatographic data were acquired using photodiode array detection. This MWAE technique was successful in recovering shikimic acid from a series of fortified plant tissues at more than 90% efficiency with an interference-free chromatogram. This allowed the use of lower amounts of reagents and organic solvents, reducing the use of toxic and/or hazardous chemicals, as compared to currently used methodologies. The method was used to determine the level of endogenous shikimic acid in several species of Brachiaria and sugarcane (Saccharum officinarum) and on B. decumbens and soybean (Glycine max) after treatment with glyphosate. The method was sensitive, rapid and reliable in all cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the large amount of pesticides applied in agriculture, mainly herbicides, there is a growing concern about a possible environmental contamination with these products, including water bodies. Given the above, the aim of the present work was to detect and quantify herbicides through multiresidue analysis in water samples collected in semi-artesian wells and springs in a rural area of the city of Jaboticabal (SP). Samples were collected from 32 wells and 13 water springs, in three different seasons: October 2010, February 2011 and May 2011. Additionally, samples at a residence in the urban area were also collected. Analysis using high performance liquid chromatography coupled to mass spectrometry was performed and herbicides ametryn, amicarbazone, clomazone, diclosulan, diuron, hexazinone, imazapic, imazapyr, isoxaflutole, S-metolachlor, sulfentrazone, sulfometuron-methyl, and tebuthiuron were evaluated. In semi-artesian wells, an incresed quantity of herbicides was found in comparison with the water springs. Among the tested herbicides, hexazinone, imazapyr and sulfentrazone were detected in measurable amounts in accordance with the analytical method applied, while clomazone was the most common herbicide being detected in more than 60% of the samples. Ametryn, diuron and amicarbazone herbicides were also detected. Diclosulan, imazapic, isoxaflutole, S-metolachlor, sulfometuron-methyl, and tebuthiuron were not detected in any sample. Inappropriate use of these products without prior knowledge of the behavior of the soil can lead to groundwaters and water springs contamination, thus an ongoing monitoring of this resource becomes very important.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pesticide residues are determined by thin layer chromatography (TLC) using the Hill reaction as a detection method. Tomatoes samples without pesticide were fortified with atrazine, diuron, chloroxuron and metribuzin, and were applyed in silica gel plates with the help of a microsyringe. The pesticides were elued with ethyl acetate. There was no need of cleaning up because no interference was noticed. After the revelation of the plates, the diameters of the spots were measure by using a rule. The range of the determined concentration for all the pesticides was from 0.1 to1.0 ng/muL. The results obtained through TLC can be used for semi-quantitative analysis.The results obtained were compared to gas and liquid chromatography, showing good agreement between both techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The genus Plumbago belongs to the family Plumbaginaceae, order Plumbaginales. Comparative chemical profile of P. scandens (native) and P. auriculata (cultivated) was obtained by normal and reversed-phase high performance liquid chromatography with photodiode array detector. Comparison of the ultraviolet espectra and the retention times for the compounds allowed to find similar metabolic patterns in roots, stems and leaves. Four flavonoids, one phenolic acid or derivative and the naphtoquinone plumbagin were comparatively identified to standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper was to determine the 10-HDA in pure royal jelly and products containing royal jelly, using HPLC methodology. 10-HDA is the natural indicator of the presence of royal jelly in products and also gives the authenticity of pure royal jelly. The chromatographic conditions used were: isocratic system, C18-H column, auto sampler, diode array UV-VIS detector (225 nm), mobile phase with methanol/water (45:55), pH= 2.5 and a-naphtol as internal standard. The results obtained using laboratory samples for pure royal jelly were 2.37%, varying from 0.15% for honey with 10% of royal jelly to 2.10% for honey with 90% of royal jelly respectivelly. For commercial products, the 10-HDA content varied from no detectable to 0.026%. The recovery test presented a minumum of 100.44% The detection limit was 45.92 ng/mL and the quantification limit was 76.53 ng/mL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.