160 resultados para HEAT-STORAGE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dryers heated by solar energy have been constructed and used in drying whole and half jack fruit almonds. The samples were dried during the day in direct sun and in the conventional solar dryer prepared for this purpose. Another piece of equipment was built for reception and accumulation of sun energy in a body of water, which was used as a heat source for night drying. The drying with the sun energy was compared with artificial drying. The jack fruit almonds were dried whole, half, with pellicle and without it. The storage of solar energy in water was technically viable for use in night drying. The drying by combining solar dryers in the day and night periods were completed in approximately 35 hours, and were equivalent to artificial drying between 40ºC and 70ºC. Almond cut in half and the pellicle removed reduced the drying time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing demand for water resources accentuates the need to reduce water waste through a more appropriate irrigation management. In the particular case of irrigated coffee planting, which in recent years presented growth with the predominance of drip irrigation, the improvement of drip irrigation management techniques is a necessity. The proper management of drip irrigation depends on the knowledge of the spatial pattern of soil moisture distribution inside the wetted strip formed under the irrigation lines. In this study, grids of 24 tensiometers were used to determine the water storage within the wetted strip formed under drippers, with a 3.78 L h-1 discharge, evenly spaced by 0.4 m, subjected to two different management criteria (fixed irrigation interval and 60 kPa tension). Estimates of storage based on a one-dimensional analysis, that only considers depth variations, were compared with two-dimensional estimates. The results indicate that for high-frequency irrigation the one-dimensional analysis is not appropriate. However, under less frequent irrigation, the two-dimensional analysis is dispensable, being the one-dimensional sufficient for calculating the water volume stored in the wetted strip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The existence of a minimum storage capacity of grains as a condition for the maintenance of regulator physical stocks has been used as a strategic factor in the agribusiness expansion. However, in Brazil the storage infrastructure has not followed the growth of the agricultural sector. This fact is evident in the case of soybeans that currently represent 49% of grain production in the country, whose volume production has been increasing significantly over the years. This study aimed to predict the futureneeds of static storage capacity of soybeans from historical data to estimate the investment needed to install storage units in Brazil for the next five years. A statistic analysis of collected data allowed a forecast and identification of the number of storage units that should be installed to meet the storage needs of soybeans in the next five years. It was concluded that by 2015 the soybean storage capacity should be 87 million tons, and to store 49% of soybeans produced, 1,104 storage units should be installed at a cost of R$ 442 million.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper was to observe the use of bedding (wood shavings) in physiological variables that indicate thermal stress in gestating sows. The experiment was conducted in order to evaluate the effect of two types of floor (concrete and wood shavings). Worse microclimatic conditions were observed in bedding systems (P<0.05), with an increase in temperature and enthalpy of 1.14 ºC and 2.37 kJ.kg dry air-1, respectively. The floor temperature at the dirty area was higher in the bedding presence in comparison to its absence. In spite of the worse microclimatic conditions in the bedding, the rectal temperature did not differ significantly (P>0.05) but the skin surface temperature was higher in the bedding systems. The same occurred with the respiratory rates. The physical characteristics of the floor material influenced the rate of heat loss by conductance. Estimated values were 35.04 and 7.99 W m-2 for the conductive heat loss between the animal and floor for treatments with or without bedding, respectively. The use of bedding in sow rearing has a negative impact on microclimatic conditions, what implies in thermoregulatory damages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After hatching, pullets are transported to brooding area and vaccinated. One day old chicks have not already developed thermoregulation ability; thus, brooding temperature variations may affect pullet quality leading to broiler meat production losses. This research aimed to calculate sensible heat loss in one day old pullets in hatching area and vaccination room. Ten one day old pullets were randomly selected from hatching area of a commercial hatchery. Infrared images were used to calculate bird surface temperature. Exposure areas for the two conditions were quantified, and both air temperature and wind speed was recorded. Total sensible heat loss was calculated as heat loss by radiation plus heat loss by convection. It was found that heat transfer occurs in different ways at different bird body parts. Total heat loss found for hatching baskets was equivalent to 0.81 J s-1 while for vaccination room was 1.16 J s-1. Pullet nutrition is based on energy loss from brooding to farm, and the overall pullet heat loss from hatchery to farm accepted is 13.95 J s-1. Thus, "starter feed" has relevant excess of energy input. These findings indicate that less energy can be used in initial feed, once heat loss is lower than assumed nowadays. Improved knowledge on these conditions may enhance broiler farm feeding strategies and economics during first rearing week.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pigs are more sensitive to high environmental temperatures explained by the inability of sweating and panting properly when compared to other species of farmed livestock. The evaporative cooling system might favor the thermal comfort of animals during exposure to extreme environmental heat and reduce the harmful effects of heat stress. The purpose of this study was to assess the sensible heat loss and thermoregulation parameters from lactating sows during summer submitted to two different acclimatization systems: natural and evaporative cooling. The experiment was carried out in a commercial farm with 72 lactating sows. The ambient variables (temperature, relative humidity and air velocity) and sows physiological parameters (rectal temperature, surface temperature and respiratory rate) were monitored and then the sensible heat loss at 21days lactation was calculated. The results of rectal temperature did not differ between treatments. However, the evaporative cooling led to a significant reduction in surface temperature and respiratory rate and a significant increase in the sow's sensible heat loss. It was concluded that the use of evaporative cooling system was essential to increase sensible heat loss; thus, it should reduce the negative effects of heat on the sows' thermoregulation during summer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Given the need to obtain systems to better control broiler production environment, we performed an experiment with broilers from 1 to 21 days, which were submitted to different intensities and air temperature durations in conditioned wind tunnels and the results were used for validation of afuzzy model. The model was developed using as input variables: duration of heat stress (days), dry bulb air temperature (°C) and as output variable: feed intake (g) weight gain (g) and feed conversion (g.g-1). The inference method used was Mamdani, 20 rules have been prepared and the defuzzification technique used was the Center of Gravity. A satisfactory efficiency in determining productive responses is evidenced in the results obtained in the model simulation, when compared with the experimental data, where R2 values ​​calculated for feed intake, weight gain and feed conversion were 0.998, 0.981 and 0.980, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT A portable flow board system was developed in the present study with the aim to facilitate lab-scale experiments of controlled atmosphere (CA) with fruits and vegetables. This sturdy flow board combines ease fabrication, low cost and gas economy. Its functionality is provided by manifolds and gas mixers. Each gaseous component is supplied by a gas cylinder through a differential valve of adjusted pressure control, generally at 6 kPa, and forced through 13 standardized restrictors coupled to each manifold output. Controlled atmospheres are then formed with one, two or three gases in 13 gas mixers affixed to the flow board base, which are further conducted through flexible tubes to storage mini-chambers that can also be used to study metabolic consumption and production of gaseous components. The restrictors used in the flow gaseous components were manufactured from microhematocrit test-type capillary glass tubes following the hot forming method under continuous air flow. The portable flow board showed to be low cost and simple post-harvest equipment that allows preparing controlled atmospheres in open systems with stable composition and flow, in a manner similar to traditional flow boards with control of gas escape by barostats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Global warming increases the occurrence of events such as extreme heat waves. Research on thermal and air conditions affecting broiler-rearing environment are important to evaluate the animal welfare under extreme heat aiming mitigation measures. This study aimed at evaluating the effect of a simulated heat wave, in a climatic chamber, on the thermal and air environment of 42-day-old broilers. One hundred and sixty broilers were housed and reared for 42 days in a climatic chamber; the animals were divided into eight pens. Heat wave simulation was performed on the 42nd day, the period of great impact and data sampling. The analyzed variables were room and litter temperatures, relative humidity, concentrations of oxygen, carbon monoxide and ammonia at each pen. These variables were assessed each two hours, starting at 8 am, simulating a day heating up to 4 pm, when it is reached the maximum temperature. By the results, we concluded that increasing room temperatures promoted a proportional raise in litter temperatures, contributing to ammonia volatilization. In addition, oxygen concentrations decreased with increasing temperatures; and the carbon monoxide was only observed at temperatures above 27.0 °C, relative humidity higher than 88.4% and litter temperatures superior to 30.3 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study was to evaluate whether allergenic extracts of five house dust and storage mite species standardized for humans might be used for the diagnosis of canine atopic dermatitis (CAD). Extracts of Dermatophagoides pteronyssinus (Pyroglyphidae), D. farinae (Pyroglyphidae), Blomia tropicalis (Glycyphagidae), Lepidoglyphus destructor (Glycyphagidae) and Tyrophagus putrescentiae (Acaridae) were evaluated by intradermal testing in 20 healthy dogs (control) and 25 dogs with allergic dermatitis. A significant difference in the response was observed between the two groups (p<0.05). Only one dog (5%) in the control group reacted to the intradermal test, whereas 14 dogs (56%) in the allergic group were positive for at least one extract (odds ratio = 24.2). Most of the positive reactions observed in the allergic group occurred against the extracts of T. putrescentiae or L. destructor, each inducing reactions in 10 dogs (40%). D. farinae, D. pteronyssinus e B. tropicalis extracts induced reactions in 7 (28%), 3 (12%) and 3 (12%) dogs, respectively. The allergenic extracts standardized for humans evaluated in the present study may be used as a tool to complement the diagnosis of the disease, as well as to select potential allergen candidates for allergen-specific immunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: The paired oviducal glands of immature and mature females of Mustelus schmitti were examined macro and microscopically. Findings indicate that these glands possessed the same zonation as in most chondrichthyans from anterior to posterior: club, papillary, baffle and terminal zones. The whole gland is composed by simple tubular glands that connect with transverse grooves all along the organ. The club zone presents a typical indian club shape with a simple columnar and ciliated epithelium including secretory cells PAS (+) and AB (+). The papillary zone is characterized by lamella forming small and long cones in numbers of three. The epithelium of this zone contains ciliated cells with apical nuclei and secretory cells with basal nuclei that stain AB (+)The baffle zone consists of apically flattened lamellae alternating with spinnerets which are small projections disposed by both sides of the plateau. This whole structure is present in number of 8 or 9 units. A simple columnar ciliated epithelium covers the plateau and spinnerets and no AB or PAS staining is observed. The epithelium of the terminal zone is PAS (-) and AB (+), and elongated tubules, that run adjacent to the baffle zone are the site where groups of spermatozoa are clearly observed in the lumen. The epithelium of the sperm storage tubules do not stain with any of the dyes tested. Sperm was also observed in the baffle zone, presumably in its way to the fecundation in the oviduct because it displays no aggregation pattern and was between the folds of the epithelium. By scanning electron microscopy sperm was observed in the club and baffle zones in a gland which belonged to a pregnant female.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work studies the forced convection problem in internal flow between concentric annular ducts, with radial fins at the internal tube surface. The finned surface heat transfer is analyzed by two different approaches. In the first one, it is assumed one-dimensional heat conduction along the internal tube wall and fins, with the convection heat transfer coefficient being a known parameter, determined by an uncoupled solution. In the other way, named conjugated approach, the mathematical model (continuity, momentum, energy and K-epsilon equations) applied to tube annuli problem was numerically solved using finite element technique in a coupled formulation. At first time, a comparison was made between results obtained for the conjugated problem and experimental data, showing good agreement. Then, the temperature profiles under these two approaches were compared to each other to analyze the validity of the one-dimensional classical formulation that has been utilized in the heat exchanger design.