192 resultados para Cold plasma
Resumo:
The inhibition of ethylene action by 1-methylcyclopropene (1-MCP) extends shelf and storage life of many climacteric fruits. However, 1-MCP appears to have limited effects on stone fruit depending on specie and cultivar. The effects of 1-MCP on ripening and quality of 'Laetitia' plums were determined during ripening at 23ºC following harvest and cold storage. Japanese plums (Prunus salicina, cv. Laetitia) were harvested at mature pre-climacteric stage, cooled to 2ºC within 36 hours of harvest and then treated with 0, 0.05, 0.10, 0.50 or 1.00 muL L-1 of 1-MCP at 1°C for 24 hours. Following treatment, fruits were either held at 23ºC for 16 days or stored at 1ºC for 50 days. Fruits were removed from cold storage at 10-day intervals and allowed to ripe at 23°C for five days. A delay of climacteric respiration and ethylene production by 1-MCP treatment during ripening following harvest and cold storage was associated to a slow rate of fruit softening. 1-MCP treatment also delayed the loss of titratable acidity and changes of flesh and skin color, whereas it had little or no effect on soluble solids content. 1-MCP effects were concentration- and storage duration-dependent and, generally, a saturation fruit response to 1-MCP occurred between 0.5 and 1.0 muL L-1. During ripening, 1-MCP treated fruits attained quality similar to that of controls. Results indicated that 1-MCP treatment may extend shelf life (23ºC) and storage life (1ºC) of 'Laetitia' plums by approximately six and 20 days, respectively.
Resumo:
Pupae of Trissolcus basalis (Wollaston) and Telenomus podisi Ashmead (Hymenoptera: Scelionidae) were stored at 12ºC and 15ºC for 120-210 days, after different periods of parasitism at 18ºC in order to evaluate adult emergence, longevity and ovipositional capacity. There was no emergence of adults at 12ºC. The rate of emergence of parasitoids transferred to 15ºC at the beginning of the pupal stage was 1.5% and 26.3%, for T. basalis and T. podisi respectively, whereas those parasitoids transferred one day before the expected date of emergence at 18ºC showed 86.4% of emergence for T. basalis and 59.9% for T. podisi. Mean adult longevity was also significantly lower when pupae were transferred to 15ºC at the beginning of the pupal stage. Females emerged after storage and maintained for 120 to 210 days at 15ºC parasitized host eggs after transference to 25ºC; however, fecundity of T. podisi was reduced in about 80% after cold storage.
Resumo:
The objective of this work was to evaluate the effect of photoperiod on luteinizing hormone (LH) plasma levels and gonadal maturation of lambari females. One hundred and twenty adult lambaris, distributed into 12 aquaria of 20 L each, were randomly subjected to three different treatments, in a completely randomized design, and four replicates. Treatments were photoperiods in hours of light (L) and darkness (D): T1, 0 L:24 D; T2, 12 L:12 D; T3, 24 L:0 D. After 40 days, fish were subjected to fasting for 24 hours and, then, anesthetized. Immediately after slaughter, fish were weighed, and their gonads and livers were removed and weighed. Ovaries were weighed and immersed in Bouin's fixative solution for 24 hours and, then, kept in 70% alcohol until processing the material. Subsequently, the oocyte developmental stage was determined. No significant differences were observed between treatments for final weight, ovary weight, gonadosomatic index (GSI), hepatosomatic index (HSI) and LH levels. In all treatments, lambari females showed maturing ovaries with prevalence of vitellogenic oocytes. Photoperiod does not affect the LH levels and ovarian maturation in lambari females.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
A column packed with 5-(4-dimethylaminobenzylidene)rhodanine adsorbed on silica gel was used for the preconcentration of Cd, Ni and Zn at different spiked solutions prior to their determination by inductively coupled plasma atomic emission spectrometry. This column allowed recoveries over than 98% for the above elements and accurate analyses of coastal sea-water certified reference material were also achieved.
Resumo:
A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.
Resumo:
The historical development of atomic spectrometry techniques based on chemical vapor generation by both batch and flow injection sampling formats is presented. Detection via atomic absorption spectrometry (AAS), microwave induced plasma optical emission spectrometry (MIP-OES), inductively coupled plasma optical emission spectrometry (ICP-OES) , inductively coupled plasma mass spectrometry (ICP-MS) and furnace atomic nonthermal excitation spectrometry (FANES) are considered. Hydride generation is separately considered in contrast to other methods of generation of volatile derivatives. Hg ¾ CVAAS (cold vapor atomic absorption spectrometry) is not considered here. The current state-of-the-art, including extension, advantages and limitations of this approach is discussed.
Resumo:
The goal of this study was to evaluate the feasibility of direct introduction of clay slurries in an inductively coupled plasma optical emission spectrometer with axial view configuration. Calibration was performed using a certified reference material with a mean particle size of 13 µm (IPT-42) and the analytical curve was applied for quantification of two others reference materials (IPT-28 and IPT-32) and four samples. It was demonstrated that the analytical curve thus obtained was not completely suitable for IPT-28 and samples due to different mineralogical phases determined by X-ray diffraction. After considering this effect, it was possible for most elements to obtain results in agreement with certified values or with values obtained by a conventional technique at a 95% confidence level. It was demonstrated that the ICP-OES with axial view configuration did not present any incompatibility with the direct introduction of a complex inorganic suspension.
Resumo:
The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.
Resumo:
Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.
Resumo:
Lead absorption is influenced by the species that are formed and the physicochemical characteristics of lead, among others. Lead plasma concentration is < 5% of total blood lead and represents the biologically active fraction able to cross the cell membranes. Health risks mainly depend on a specific metal and its species. Speciation analysis is the analytical activity of identifying and determining different metal species. Chromatographic methods are very useful in the identification of species and the techniques most used to determine metals in biological fluids are ICP OES/MS and AAS. Lead speciation analysis in blood plasma is fundamental for understanding and evaluating the interaction mechanisms between that analyte and its biological targets.
Resumo:
The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.
Resumo:
The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.
Resumo:
In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.
Resumo:
Analysis of diazepam (DZP) and its active metabolite nordiazepam (NDZP) in plasma is commonly performed in clinical medicine to ensure proper therapeutic effects while minimizing the incidence of toxicity. This study aimed to optimize analytical parameters and compare two pre-treatment techniques, liquid-liquid (LLE) and solid phase extraction (SPE), as well as liquid chromatographic conditions to analyze simultaneously DZP and NDZP in plasma from 20 patients treated with a daily dose of 10 mg. Both techniques showed to be well in line with the international criteria for analytical validation, which permitted to quantify DZP (66.2 - 1148.6 ng mL-1) and NDZP (138.5 - 808.6 ng mL -1) in all samples. The correlation coefficients between SPE and LLE were respectively 0.9729 for DZP and 0.9643 for NDZP.