773 resultados para Determinação direta
Resumo:
One of the difficulties reported for the suspension polymerization is control the size and granulometry of beads. The purpose of this work was to evaluate the use of cellulose nanowhiskers and mesoporous silica as stabilizers to reduce the size and the particle distribution. To monitor polymerization process was used FTIR-ATR spectroscopy. The morphology was analyzed by scanning electron microscopy. The particle size distribution was characterised using a CILAS granulometer. Thermal stability was studied by thermogravimetric analysis. The results indicated that cellulose nanowhiskers may provide stabilization and increase the thermal stability of the beads in contrast to mesoporous silica.
Resumo:
This work describes the evaluation of the effect of saponification process in the carotenoid's content of three species of passion fruit. The results indicated the saponification of the extract was necessary to obtain cis-violaxanthin, trans-violaxanthin and β-cryptoxanthin hydrolyzed. These compounds were found in fruits of commercial P. edulis and yellow wild P. edulis. However, the extract saponification did not permitted to obtain free carotenes in fruits of wild purple P. edulis and P. setacea, and to trans-violaxanthin of P. cincinnata, therefore saponification was not indicated in the carotenoid analysis of these three accessions of passion fruit.
Resumo:
This paper presents a practical and rapid method which was validated for simultaneous quantification and confirmation of 29 pesticides in fruits and vegetables using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The samples were extracted following the method known as QuEChERS. Using the developed chromatographic conditions, the pesticides can be separated in less than 9 min. Two multiple reaction monitoring (MRM) assays were used for each pesticide. Four representative matrices (lettuce, tomato, apple and grapes) were selected to investigate the effect in recoveries and precision. Typical recoveries ranged from 70-120%, with relative standard deviation (RSDs) lower than 20%.
Resumo:
This paper describes an analytical method for analyzing polychlorinated biphenyls in corn samples using solid phase extraction (SPE) followed by determination by GC-MS. All calibration curves proved linear (r> 0.99). Recoveries ranged between 74.1 and 110.6% with relative standard deviation lower than 20% for all compounds. The limits of quantitation for the method were between 0.025 and 0.1 ng g-1. Of the 51 samples analyzed, PCB 180 showed the highest frequency, being detected in more than 39%, followed by PCB 138, detected in more than 33% of samples.
Resumo:
Corals incorporate major and trace elements in their tissues and skeletons, acting as good proxies for contaminant inputs over time. This incorporation occurs by a variety of mechanisms and depends on the bioavailability of elements. Corals are very susceptible to metal contamination during sample collection. As such, pre-treatment procedures need to include a decontamination step. The high Na and Ca concentrations in the matrix make the determination of trace metals an analytical challenge. The present paper reviews all the information published on coral sample pretreatments, metal determinations in corals, and also discusses the use of coral to monitor metal contamination.
Resumo:
A method based on enzymatic activities was developed using three enzymes (glycerokinase, glycerol-3-phosphate oxidase and peroxidase) and colorimetric detection for the determination of glycerol in biodiesel. The enzymatic conversion of glycerol produces H2O2 that is eliminated by the action of peroxidase, an oxygen acceptor and 4- aminoantipirine, producing water and a colored compound, which was analyzed. This method showed good linear correlation coefficient (r = 0.9937) in the concentration range of 4.95 x 10-5 to 3.96 x 10-4% (w/w) and had experimental limits of detection and quantitation of 7.10 x 10-6 and 2.10 x 10-5% (w/w), respectively.
Resumo:
Two methods for the determination of Ivermectin in veterinarian medications were developed and compared. One of the methods was based on UV spectrometry and the other on HPLC-UV. The former method was shown to be positively biased regarding the nominal concentrations of Ivermectin in different medications. The method of standard addition was unable to correct this bias, indicating significant matrix effects. The HPLC-UV method showed good linearity, throughput, recovery and limits of detection and quantitation adequate for its application in the evaluation of Ivermectin in medications. Several medications were evaluated and good agreement between our results and their nominal concentrations was found.
Resumo:
Simple, sensitive and accurate spectrophotometric derivative methods were developed for the simultaneous determination of olanzapine and fluoxetine hydrochloride in pharmaceutical formulations by derivative spectrophotometry. On all orders of derivative studied, the linear response range was 10 to 60 mg L-1, with limit of quantitation (LoQ) ranging from 0.73 to 1.49 mg L-1 for fluoxetine hydrochloride and from 0.18 to 0.96 mg L-1 for olanzapine. The best orders for derivative analyses showed recoveries ranging from 99 to 103% and from 98 to 100%, and inter-day accuracy < 2.1% and < 2.8%, for fluoxetine hydrochloride and olanzapine, respectively.
Resumo:
Sulfasalazine is a prodrug used in the treatment of the Chron's disease and rheumatoid arthritis. Two analytical methods for analysis of sulfasalazine in oral suspension were validated using Spectrophotometric and HPLC. There is not any pharmacopoeic method to assay sulfasalazine in oral suspension. The methods are insurance and fast execution for the quality control. Both, suspension and tablets 500 mg (Azulfin®) had been analyzed by methods using UV/VIS and HPLC and the results were satisfactory.
Resumo:
This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.
Resumo:
A simple, fast and inexpensive method was developed to determine essential elements in pellets of rice samples using energy dispersive X-ray fluorescence spectrometry (EDXRF). The accuracy and precision were evaluated using Standard Reference Material (rice flour NIST 1568a), and yielding relative standard deviation below 5%. The paired t-test showed good agreement within 95% confidence values. The detection limits (3σ) of Mn and Zn were 5.1 and 2.2 mg kg-1, respectively. The proposed method proved to be effective when used to determine Mn and Zn in commercial samples of rice without go by stage of decomposition.
Resumo:
A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.
Resumo:
The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).
Resumo:
The QuEChERS extraction method followed by quantification using HPLC/UV-FL was evaluated for deoxynivalenol (DON) and zearalenone (ZEA) determination in natural and parboiled rice and their fractions (bran and husk). The comparison between QuEChERS and partition with acetonitrile extraction showed that the first one was better. It presented higher recovery (91% for DON, 105% for ZEA) wih precision ranging from 1.5 to 18.6%. The limits of quantification were 22.2 µg kg-1 for DON and 4.3 µg kg-1 for ZEA. DON and ZEA showed higher levels in endosperm of parboiled rice (8 e 111.7 µg kg-1, respectively) when compared to natural rice.
Resumo:
The performance of inductively-coupled plasma optical emission spectrometers with axial and radial views for determination of iodine in table salt was evaluated. Interference and memory effects in nitric acid and water-soluble tertiary amines (CFA-C) media were studied. Based on a factorial experiment, one optimum instrument operational condition for axial configuration, and two optima conditions for radial configuration was established. The ICP OES with axial view was 5-fold more sensitive than the radial view. Both matrix matching and standard addition methods were used for iodine quantification and for most samples, both strategies of calibration led to similar results. Recoveries ranged from 104 to 114%.