55 resultados para on-line sample preparation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes CE preconcentration strategies based on the effect of manipulation of the disperse/secondary velocity. Introduced by Terabe et al. in 1984, micellar electrokinetic chromatography is a powerful separation approach that increases the usage of electrokinetic phenomena for the separation of nonionic compounds. The main disadvantage of MEKC is the low concentration sensitivity associated with the limited optical path length for on-capillary photometric detection and the limited volume of sample solution that can be injected. This paper compiles on-line concentration strategies for neutral analytes by sample stacking and sweeping in micellar electrokinetic chromatography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high performance liquid chromatographic-diode array detection method for the determination of busulfan in plasma was developed and validated. Sample preparation consisted of protein precipitation followed by derivatization with sodium diethyldithiocarbamate and liquid-liquid extraction with methyl-tert-butyl ether. Chromatograms were monitored at 277 nm. Separation was carried out on a Lichrospher RP 18 column (5 µm, 250 x 4 mm). The mobile phase consisted of water and acetonitrile (20:80, v/v). The method presented adequate specificity, linearity, precision and accuracy and allowed reliable determination of busulfan in clinical plasma samples, being applied to three patients submitted to bone marrow transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drugs of abuse are commonly used outside medical or legal settings where their production, marketing and consumption are subject to legal summons and/or intervention. Classified as emerging contaminants, these substances have been recently detected in samples of environmental concern, such as waters and wastewaters. This review presents the state-of-the-art on the methodological approaches used in sample preparation, the main techniques applied in analytical determination at trace levels, as well as the use of information related to the drug or its metabolite concentration in sewage samples to empirically estimate the consumption of drugs of abuse in a city or region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method based on pyrohydrolysis was proposed for cement sample preparation and further chloride determination by spectrophotometry using flow injection analysis. Analytical parameters were evaluated and, under the selected conditions, the calibration curve was linear in the range of 0.2 to 10.0 µg mL-1 with r2 = 0.998. The limit of detection was5 µg g-1 of chloride and the relative standard deviation was less than 7%. The proposed pyrohydrolysis method is relatively simple and can be used for sample preparation for further spectrophotometric determination of low concentrations of chloride in cement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Difenoconazole residues in strawberry fruit cultivated in pots were estimated using the solid-liquid extraction with low temperature partition (SLE/LTP) method for sample preparation and gas chromatography with electron capture detection (GC/ECD) for analysis. The optimized method presented excellent recovery values from fortified samples and reproducibility (average recovery values ≥ 98%; CV values < 15%). Linearity of response was demonstrated (r = 0.995) with a detection limit of 9 µg kg-1. The method was successfully applied for the determination of difenoconazole residues in strawberries. Based on these results, the fungicide dissipates quickly, but the residual concentration increases after multiple applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 ºC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractThe aim of this study was to analyze the impact that heat treatment with salts and freezing processes on the sensory, instrumental, and physico-chemical characteristics of fried potatoes of the Monalisa cultivar. The potatoes were blanched in distilled water (P); sodium chloride solution (B1); calcium chloride solution (B2), and a solution with both of these salts (B3). They were then pre-cooked and frozen for 24 hours and for 30 days. After frying, sensory characteristics were analyzed (color, texture, flavor, oiliness), along with overall preference and instrumental determinations of texture, color, and oil content. Further tests were conducted on the sample with the best results in the sensory analysis (B1), along with sample P as a control, to determine granule microstructure, carbohydrate fractions, glycemic index, and glycemic load. Blanching B3, despite reducing oil absorption and providing less oiliness, obtained lesser overall preference. Freezing for 30 days increased the lightness, except for when sodium chloride was used, which intensified the color yellow. The use of sodium chloride did not interfere with the type of starch granules, nor with the formation of resistant starch; however, longer freezing time reduced the glycemic index and concentrated the dietary fiber content. All samples exhibited low glycemic index and moderate glycemic loads.