75 resultados para hydrophobic chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d.) using a mobile phase (methanol and water , 90:10, v/v) containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eight bufadienolides were successfully isolated and purified from ChanSu by high-speed counter-current chromatography (HSCCC) combined with preparative HPLC (prep-HPLC). First, a stepwise elution mode of HSCCC with the solvent system composed of petroleum ether - ethyl acetate - methanol - water (4:6:4:6, 4:6:5:5, v/v) was employed and four bufadienolides, two partially purified fractions were obtained from 200 mg of crude extract. The partially purified fractions III and VI were then further separated by prep-HPLC, respectively, and another four bufadienolides were recovered. Their structures were confirmed by ESI-MS and ¹H-NMR spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of pH-zone-refining counter-current chromatography was successfully applied to preparatively separate three C19-diterpenoid alkaloids from the crude extracts of Aconitum carmichaelii for the first time using a two-phase solvent system of petroleum ether-ethyl acetate-methanol-water (5:5:1:9, v/v/v/v). Mesaconitine (I), hypaconitine (II), and deoxyaconitine (III) were obtained from 2.5 g of the crude alkaloids in a one-step separation; the yields were 4.16%, 16.96%, and 5.05%, respectively. The purities of compounds I, II, and III were 93.0%, 95%, and 96%, respectively, as determined by HPLC. The chemical structures of the three compounds were identified by electrospray ionization mass spectrometry (ESI-MS) and NMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separations using supercritical fluid chromatography (SFC) with packed columns have been re-discovered and explored in recent years. SFC enables fast and efficient separations and, in some cases, gives better results than high performance liquid chromatography (HPLC). This paper provides an overview of recent advances in SFC separations using packed columns for both achiral and chiral separations. The most important types of stationary phases used in SFC are discussed as well as the most critical parameters involved in the separations and some recent applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An effective method for the rapid separation and purification of three stilbenes from the radix of Polygonum cillinerve (Nakai) Ohwl by macroporous resin column chromatography combined with high-speed counter-current chromatography (HSCCC) was successfully established. In the present study, a two-phase solvent system composed of chloroform-n-butanol-methanol-water (4:1:4:2, v/v/v/v) was used for HSCCC separation. A one-step separation in 4 h from 150 mg of crude extract produced 26.3 mg of trans-resveratrol-3-O-glucoside, 42.0 mg of pieceid-2"-O-gallate, and 17.9 mg of trans-resveratrol with purities of 99.1%, 97.8%, and 99.4%, respectively, as determined by high-performance liquid chromatography (HPLC). The chemical structures of these compounds were identified by nuclear magnetic resonance (NMR) spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilex paraguariensis (yerba-mate) is used as a beverage, and its extract requires adequate quality control methods in order to guarantee quality and safe use. Strategies to develop and optimize a chromatographic method to quantify theobromine, caffeine, and chlorogenic acid in I. paraguariensis extracts were evaluated by applying a quality by design (QbD) model and ultra high-performance liquid chromatography (UHPLC). The presence of these three phytochemical markers in the extracts was evaluated using UHPLC-MS and was confirmed by the chromatographic bands in the total ion current traces (m/z of 181.1 [M+H]+, 195.0 [M+H]+, and 353.0 [M−H]−, respectively). The developed method was then transferred to a high-performance liquid chromatography (HPLC) platform, and the three phytochemical markers were used as external standards in the validation of a method for analyses of these compounds in extracts using a diode array detector (DAD). The validated method was applied to quantify the chlorogenic acid, caffeine, and theobromine in the samples. HPLC-DAD chromatographic fingerprinting was also used in a multivariate approach to process the entire data and to separate the I. paraguariensis extracts into two groups. The developed method is very useful for qualifying and quantifying I. paraguariensis extracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3alpha-O-beta-glucopyranoside and (-)-lyoniresinol 3alpha-O-beta-glucopyranoside, being reported for the first time in Rubiaceae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Total Ammoniacal Nitrogen - TAN (NH3 + NH4+) in wastewaters cause environmental degradation concerns due to their negative impacts on air, soil and water. Several technologies are available for TAN removal from the wastewaters. One emerging technology is the use of hydrophobic membrane as non-destructive NH3 extraction. In this paper the authors discuss the uses of gas permeable membrane (GPM) and its physicochemical characteristics that influence gas mass transfer rate, diffusion and recovery mechanisms of NH3 from liquid sources (e.g. animal wastewater). Several aspects of NH3 extraction from liquid manure and other TAN generation sources using GPM technology as well as its applicability for NH3 mitigation from liquid effluents and possible recovery as a nutrient for plant growth are also discussed in this review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Billings and Guarapiranga Reservoirs were deeply affected by environmental disturbances, which more evident consequence are the cyanobacterial blooms. Microcystins are the most common cyanotoxin in freshwaters and more than 70 types are known. Different methods for microcystins analysis in water can be used, among which ELISA and HPLC are the most frequently employed. However, less sophisticated and more economic methods can also be used. This is the case of planar chromatography (thin-layer chromatography) method previously used in cyanotoxins purification but gradually replaced by others. Posterior optimization of the microcystin chromatography conditions and because of its simplicity, rapidity, efficiency and low cost, this method is again considered an option for the analysis of microcystins and nodularins. Considering the importance of Billings and Guarapiranga Reservoirs for drinking water supplies and the few scientific data about cyanobacteria and cyanotoxins in these water bodies, the aims of this work are to analyze the biodiversity of cyanobacteria in the Billings and Guarapiranga Reservoirs and the detection of dissolved microcystins in the water. It was possible to identify 17 species of cyanobacteria, 9 of them being potentially toxic. In Billings Reservoir Microcystis aeruginosa (Kützing) Kützing and Cylindrospermopsis raciborskii (Woloszynska) Seenayya & Subba Raju are the most common species, while in Guarapiranga Reservoir only M. aeruginosa was considered as a common species. Microcystins were detected in all Billings Reservoir samples and in only one sample from Guarapiranga Reservoir.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large volumes of plasma can be fractionated by the method of Cohn at low cost. However, liquid chromatography is superior in terms of the quality of the product obtained. In order to combine the advantages of each method, we developed an integrated method for the production of human albumin and immunoglobulin G (IgG). The cryoprecipitate was first removed from plasma for the production of factor VIII and the supernatant of the cryoprecipitate was fractionated by the method of Cohn. The first precipitate, containing fractions (F)-I + II + III, was used for the production of IgG by the chromatographic method (see Tanaka K et al. (1998) Brazilian Journal of Medical and Biological Research, 31: 1375-1381). The supernatant of F-I + II + III was submitted to a second precipitation and F-IV was obtained and discarded. Albumin was obtained from the supernatant of the precipitate F-IV by liquid chromatography, ion-exchange on DEAE-Sepharose FF, filtration through Sephacryl S-200 HR and introduction of heat treatment for fatty acid precipitation. Viral inactivation was performed by pasteurization at 60ºC for 10 h. The albumin product obtained by the proposed procedure was more than 99% pure for the 15 lots of albumin produced, with a mean yield of 25.0 ± 0.5 g/l plasma, containing 99.0 to 99.3% monomer, 0.7 to 1.0% dimers, and no polymers. Prekallikrein activator levels were <=5 IU/ml. This product satisfies the requirements of the 1997 Pharmacopée Européenne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain intravenous immunoglobulin G (iv IgG) of high quality from F-I+II+III or F-II+III pastes prepared by the Cohn method, we developed a chromatography process using ion exchange gels, Q-Sepharose FF and CM-Sepharose FF, and Sephacryl S-300 gel filtration. Viral inactivation was performed by incubating the preparation with pepsin at pH 4.0 at 35oC for 18 h. The characteristics of 28 batches produced by us were: yield 4.3 ± 0.2 g/l plasma, i.e., a recovery of 39.1 ± 1.8%; IgG subclasses distribution: IgG1 = 58.4%, IgG2 = 34.8%, IgG3 = 4.5% and IgG4 = 2.3%; IgG size distribution was 98.4% monomers, 1.2% dimers and 0.4% polymers and protein aggregates; anticomplement activity was less than 0.5 CH50/mg IgG, and prekallikrein activator activity (PKA) was less than 5 IU/ml. These characteristics satisfied the requirements of the European Pharmacopoea edition, and the regulations of the Brazilian Health Ministry (M.S. Portaria No. 2, 30/10/1998).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a new simple, selective and sensitive micromethod based on HPLC and fluorescence detection to measure debrisoquine (D) and 4-hydroxydebrisoquine (4-OHD) in urine for the investigation of xenobiotic metabolism by debrisoquine hydroxylase (CYP2D6). Four hundred µl of urine was required for the analysis of D and 4-OHD. Peaks were eluted at 8.3 min (4-OHD), 14.0 min (D) and 16.6 min for the internal standard, metoprolol (20 µg/ml). The 5-µm CN-reverse-phase column (Shimpack, 250 x 4.6 mm) was eluted with a mobile phase consisting of 0.25 M acetate buffer, pH 5.0, and acetonitrile (9:1, v/v) at 0.7 ml/min with detection at lexcitation = 210 nm and lemission = 290 nm. The method, validated on the basis of measurements of spiked urine, presented 3 ng/ml (D) and 6 ng/ml (4-OHD) sensitivity, 390-6240 ng/ml (D) and 750-12000 ng/ml (4-OHD) linearity, and 5.7/8.2% (D) and 5.3/8.2% (4-OHD) intra/interassay precision. The method was validated using urine of a healthy Caucasian volunteer who received one 10-mg tablet of Declinax®, po, in the morning after an overnight fast. Urine samples (diuresis of 4 or 6 h) were collected from zero to 24 h. The urinary excretion of D and 4-OHD, Fel (0-24 h), i.e., fraction of dose administered and excreted into urine, was 6.4% and 31.9%, respectively. The hydroxylation capacity index reported as metabolic ratio was 0.18 (D/4-OHD) for the person investigated and can be compared to reference limits of >12.5 for poor metabolizers (PM) and <12.5 for extensive metabolizers (EM). In parallel, the recovery ratio (RR), another hydroxylation capacity index, was 0.85 (4-OHD: SD + 4-OHD) versus reference limits of RR <0.12 for PM and RR >0.12 for EM. The healthy volunteer was considered to be an extensive metabolizer on the basis of the debrisoquine test.