The aim of this work is the production and characterization of plasma polymerized acetaldehyde thin films. These films show highly polar species, are hydrophilic, organophilic and easily adsorb organic reactants with CO radicals but only allow permeation of reactants with OH radicals. The good step coverage of films deposited on aluminum trenches is useful for sensor development. Films deposited on hydrophobic substrates may result in a discontinued layer, which allows the use of preconcentration in sample pretreatment. Deposition on microchannels showed the possibility of chromatographic columns and/or retention system production to selectively detect or remove organic compounds from gas flows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the development of a method based on the coupling of flow analysis (FA), hydride generation (HG), and derivative molecular absorption spectrophotometry (D-EAM) in gas phase (GP), is described in order to determine total antimony in antileishmanial products. Second derivative order (D²224nm) of the absorption spectrum (190 - 300 nm) is utilized as measurement criterion. Each one of the parameters involved in the development of the proposed method was examined and optimized. The utilization of the EAM in GP as detection system in a continuous mode instead of atomic absorption spectrometry represents the great potential of the analytic proposal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different methods to determine total fat (TF) and fatty acids (FA), including trans fatty acids (TFA), in diverse foodstuffs were evaluated, incorporating gravimetric methods and gas chromatography with flame ionization detector (GC/FID), in accordance with a modified AOAC 996.06 method. Concentrations of TF and FA obtained through these different procedures diverged (p< 0.05) and TFA concentrations varied beyond 20 % of the reference values. The modified AOAC 996.06 method satisfied both accuracy and precision, was fast and employed small amounts of low toxicity solvents. Therefore, the results showed that this methodology is viable to be adopted in Brazil for nutritional labeling purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas-phase SiCl3+ ions undergo sequential solvolysis type reactions with water, methanol, ammonia, methylamine and propylene. Studies carried out in a Fourier Transform mass spectrometer reveal that these reactions are facile at 10-8 Torr and give rise to substituted chlorosilyl cations. Ab initio and DFT calculations reveal that these reactions proceed by addition of the silyl cation to the oxygen or nitrogen lone pair followed by a 1,3-H migration in the transition state. These transition states are calculated to lie below the energy of the reactants. By comparison, hydrolysis of gaseous CCl3+ is calculated to involve a substantial positive energy barrier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This technical note describes the construction of a low-cost optical detector. This device is composed by a high-sensitive linear light sensor (model ILX554) and a microcontroller. The performance of the detector was demonstrated by the detection of emission and Raman spectra of the several atomic systems and the results reproduce those found in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC) the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical chemical sensor for the determination of nitrite based on incorporating methyltrioctylammonium chloride as an anionic exchanger on the triacetylcellulose polymer has been reported. The response of the sensor is based on the redox reaction between nitrite in aqueous solution and iodide adsorbed on sensing membrane using anion exchange phenomena. The sensing membrane reversibly responses to nitrite ion over the range of 6.52×10-6 - 8.70×10-5 mol L-1 with a detection limit of 6.05×10-7 mol L-1 (0.03 µg mL-1) and response time of 6 min. The relative standard deviation for eight replicate measurements of 8.70×10-6 and 4.34×10-5 mol L-1 of nitrite was 4.4 and 2.5 %, respectively. The sensor was successfully applied for determination of nitrite in food, saliva and water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry was used for the identification of forty doping agents. The improvement in the specificity was remarkable, allowing the resolution of analytes that could not be done by one-dimensional chromatographic systems. The sensitivity observed for different classes of prohibited substances was clearly below the value required by the World Anti-Doping Agency. In addition time-of-flight mass spectrometry gives full spectrum for all analytes without any interference from the matrix, resulting in selectivity improvements. These results could support the implementation of an exhaustive monitoring approach for hundreds of doping agents in a single injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nuclear magnetic resonance (NMR) is one of the most versatile analytical techniques for chemical, biochemical and medical applications. Despite this great success, NMR is seldom used as a tool in industrial applications. The first application of NMR in flowing samples was published in 1951. However, only in the last ten years Flow NMR has gained momentum and new and potential applications have been proposed. In this review we present the historical evolution of flow or online NMR spectroscopy and imaging, and current developments for use in the automation of industrial processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, portable and low-cost system for odor detection was developed using a single MOS commercial sensor and a microcontroller. The temperature modulation technique was implemented applying a DC signal pulse to the sensor heater by a bipolar transistor. Two odorant profiles, ethanol and acetic acid vapors, were obtained and distinguished based on their amplitude versus time responses. Response for acetic acid was not reported by the sensor manufacturer. An ethanol vapor calibration curve was also obtained. Experimental data showed a potential behavior according to the theoretical equation of the MOS sensors. Values of logK=0.457 and α=-0.213 for a 95% confidence level were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a discussion on light diffraction by slits and grids as well as the development of an experimental apparatus which provides quantitative observation of the phenomenon. We conducted a brief historical survey on the evolution of the wave theory of light and the role of diffraction in the context of optical spectroscopy. We also reviewed the use of Huygens’ principle to calculate the intensity pattern obtained when light is diffracted by slits and compared the predictions with experimental results obtained using the apparatus developed. Finally, the use of the apparatus in an optical spectroscopy experiment was demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zirconia was prepared by a precipitation method and calcined at 723 K, 1023 K, and 1253 K in order to obtain monoclinic zirconia. The prepared zirconia was characterized by XRD, SEM, EDX, surface area and pore size analyzer, and particle size analyzer. Monoclinic ZrO2 as a catalyst was used for the gas-phase oxidation of isopropanol to acetone in a Pyrex-glass-flow-type reactor with a temperature range of 443 K - 473 K. It was found that monoclinic ZrO2 shows remarkable catalytic activity (68%) and selectivity (100%) for the oxidation of isopropanol to acetone. This kinetic study reveals that the oxidation of isopropanol to acetone follows the L-H mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemically modified electrodes have been studied to obtain new and better electrochemical sensors. Transparent conductive oxides, such as fluorine-doped tin-oxide (FTO), shows electrical conductivity comparable to metals and are potential candidates for new sensors. In this work, FTO was modified by gold electrodeposition from chlorine-auric acid solution using cyclic voltammetry (CV) technique. A set of different materials were produced, varying the scan number. Scanning electron microscopy and electrochemical impedance spectroscopy were performed for the characterization of electrodes surfaces. From this analysis was possible to observe the resistive, capacitive and difusional aspects from all kind of modified electrodes produced, establishing a relationship between this parameters and the scan number. The electrode with 100 scans of CV presented better characteristics for an electrochemical sensor; it has the lowest global impedance and rising of capacitive behavior (related to electrical double layer formation) at lower frequencies. This electrode was tested for paracetamol and caffeine detection. The results showed a high specificity, decreased oxidation potential (0.58 V and 0.97 Vvs. SCE, for paracetamol and caffeine, respectively) and low detection limits (0.82 and 0.052 µmol L-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No presente trabalho, foi desenvolvido um eletrodo de PbO2 eletrodepositado sobre grafite a partir do eletrólito metanosulfonato de chumbo-ácido metanosulfônico contendo o agente tensoativo brometo de cetiltrimetilamônio (BCTA). Foram avaliadas a resposta potenciométrica do eletrodo de PbO2 como sensor à íons Pb2+ e SO4(2-), em pH e força iônica constante. A aplicação deste eletrodo em titulações potenciométricas de precipitação em meio hidro-etanólico também foi investigada. Os resultados demonstraram que o eletrodo de PbO2 eletrodepositado pode ser utilizado como sensor potenciométrico alternativo à íons Pb(II) apresentando uma linearidade na faixa de concentração de 3,98x10-4 a 3,09x10-2 mol L-1 em meio de íons nitrato com limite de detecção de (4,98 ± 0,11)x10-4 mol L-1. Para íons sulfato o eletrodo de PbO2 não responde diretamente porém, estes íons podem ser dosados indiretamente por titulação potenciométrica com solução padrão de Pb(II), em meio ácido, em uma mistura 1:1 (v/v) de etanol-água, com boa definição dos volumes de equivalência. A repetitividade dos potenciais e dos volumes de equivalência obtidos em amostras de concentração milimolar em sulfato, indicam a viabilidade deste eletrodo na dosagem de íons sulfato.