357 resultados para cloreto de itérbio
Resumo:
RESUMO Objetivou-se com este estudo avaliar revestimentos comestíveis à base de goma xantana e glicerol, combinada a cloreto de cálcio, ácido oleico e/ou óleo essencial de hortelã-pimenta na conservação de morangos cv. Festival. Os morangos foram selecionados, lavados, sanitizados e, a seguir, submetidos a diferentes tratamentos de revestimentos à base de goma xantana acrescidos de glicerol, cloreto de cálcio, ácido oleico e/ou óleo essencial de hortelã-pimenta. Os frutos foram secos sob ventilação forçada a 4 ºC, por 15 h, e, posteriormente, embalados em bandejas com tampa de Polietileno Tereftalato (PET) e armazenados a 4 ºC, durante 12 dias. Foram realizadas análises de perda de massa, firmeza, luminosidade, tonalidade, pH, acidez, sólidos solúveis totais, antocianinas e a incidência de deterioração fúngica. Os diferentes revestimentos utilizados foram eficientes na conservação dos morangos. O tratamento com goma xantana e glicerol apresentou os melhores resultados, pois a influência do ácido oleico ou do óleo essencial de hortelãpimenta, assim como do cloreto de cálcio, não foi significativa. O revestimento de goma xantana proporcionou redução da perda de massa, manutenção da firmeza, cor, pH, acidez, sólidos solúveis totais, antocianinas e não estimulou o crescimento fúngico. Desta forma, esta goma apresenta potencial para aplicação como revestimento em morangos, visando a maximizar a vida útil deste produto.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
The effects of chloride and nitrate anions and their respective concentrations, as well as urea presence, on solid phase morphologies were investigated. Zinc hydroxide carbonate was prepared by aging diluted zinc salt solution in presence of urea at 90ºC. Samples were identified by X-ray powder diffractograms showing the characteristic patterns of hydrozincite. The crystallinity was correlated with the concentrations of reagents. Spherulitic-type aggregates and single acicular particles were obtained from diluted chloride and nitrate solutions while porous aggregates of uniform size were formed from solutions with high chloride and urea concentrations.
Resumo:
Chloride poisoning is known as having an inhibitor effect in the activity of metal catalysis. In this work in situ infrared spectroscopy (FTIR) of adsorbed carbon monoxide and x-ray photoelectron spectroscopy (XPS) were used to investigate the effect of chloride presence in the electronic metal density in the d subshell of palladium dispersed on alumina. The chloride poisoning effect was interpreted as an electronic effect since a weak back-bonded Pd-CO was formed due to the decrease in the electronic density of the d subshell of palladium, which could be also detected by the higher Pd 3d5/2 binding energy in the chloride presence. A similar poisoning effect was also observed for chloride free Pd/Al2O3 reduced at 500 ºC, and it was interpreted based on the interaction of metal with the alumina surface. The use of molybdena/alumina binary system as support, yield a contrary effect due to the metal-support interaction.
Resumo:
The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.
Resumo:
A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.
Resumo:
The aromatic six-membered heterocycles having three nitrogen atoms are denominated triazines. Among these heterocycles, isocyanuric chloride and cyanuric chloride are inexpensive and readily available 1,3,5-triazine derivatives, which have been attracting significant attention of organic chemists due to their different kinds of applications, which vary from pharmaceuticals to explosives. This short overview explores their uses in synthetic methods, as chlorinating and oxidating agents and some procedures for their preparation.
Resumo:
In this work, we describe a new method for obtaining [Fe(CO)2[(eta5-C5H5)Cl] employing simple techniques and low-cost reagents. It is worth mentioning that this method is faster than others reported in the literature. It was applied in laboratory classes for undergraduate students, exploring different concepts in organometallic chemistry and discussing the steps involved in the synthetic route.
Resumo:
This experiment, where very common materials and equipments are used, conducts to good and interesting results related to the ionic radii of sodium and chloride ions. It also offers an excellent opportunity to discuss the crystalline arrangement of solids and to apply simple mathematical tools for calculations. Other important concepts such as density, solubility and saturated solution are also used. The simplicity of the experiment creates an excellent opportunity for reasoning with the students about the technique.
Resumo:
The aim of this study was to verify the influence of the apparent molecular size of aquatic humic substances on the effectiveness of coagulation with ferric chloride. Coagulation-filtration tests using jar test and bench-scale sand filters were carried out on samples of water with true color of approximately 100 Hazen units, prepared with aquatic humic substances of different molecular sizes (F1: < 0.45 µm, F2: 100 kDa - 0.45 µm, F3: 30 - 100 kDa and F4': < 30 kDa). For the water samples with lower apparent molecular size fractions, greater dosages of coagulant was needed to remove the color around 5.0 Hanzen units, mainly because these water samples contain higher concentrations of fulvic acids, which exhibited a larger number of negatively-charged groups.
Resumo:
Samplings of atmospheric particulate matter (PM) were carried out between the months of March and April of 2007, simultaneously in two areas of Londrina, an urban (Historical Museum) and other rural (Farm School-UEL). PM was collected using the cascade impactor consisting of four impaction stages (0.25 to 10 μm). The results indicated that the fine fraction (PM2.5) represented a significant portion of the mass of PM10 (70 and 67% in the urban and rural places, respectively). Cl-, NO3- and SO4(2-) were determined by ion chromatography and the size distribution is presented. Natural and anthropogenic sources were suggested to the ionic components in the fine and coarse mode of PM.
Resumo:
Binary mixture phase diagrams are normally obtained from thermal analysis involving freezing point curves. However, that approach is not always reliable and easy to follow to all kinds of mixtures in any proportion. In fact, even for a simple system, such as NaCl-H2O, this freezing methodology gives mixed results when one starts from a solid-solution system, due mostly to the formation of the NaCl.2H2O, which has an incongruent melting point, and the dependence of its solubility with the temperature. In this work we report a trustworthy, simple and cheap method involving heating curves to drawn the NaCl-H2O phase diagram.
Resumo:
The quaternary chitosan was synthesized by reaction of chitosan with glycidyl trimethylammonium chloride. it was characterized by infrared spectra and conductometric titration. Adsorption of reactive blue 4 (RB4) and reactive red 120 (RR120) by quaternary chitosan was studied from aqueous medium. Two kinetic adsorption models were tested: pseudo first-order and pseudo second-order. The experimental data best fitted the pseudo second-order model. The Langmuir isotherm model provided the best fit to the equilibrium data in the concentration range investigated and the maximum adsorption capacity determined was 415 mg (RR120) and 637 mg (RB4) of reactive dye per gram of adsorbent.
Resumo:
Interlaboratorial comparison of the determination of hardness and chloride in water had been performed by 38 and 37 laboratories, respectively. In all cases the participating laboratories used its routine methods. Homogeneity and stability testing were performed on the samples sent to the laboratories. The codified results are graphically reported and compared to assigned value, determined by the consensus of the laboratories. Satisfactory results were obtained for 71 and 73% of the laboratories, considering hardness and chloride determination, respectively.
Resumo:
A method based on pyrohydrolysis was proposed for cement sample preparation and further chloride determination by spectrophotometry using flow injection analysis. Analytical parameters were evaluated and, under the selected conditions, the calibration curve was linear in the range of 0.2 to 10.0 µg mL-1 with r2 = 0.998. The limit of detection was5 µg g-1 of chloride and the relative standard deviation was less than 7%. The proposed pyrohydrolysis method is relatively simple and can be used for sample preparation for further spectrophotometric determination of low concentrations of chloride in cement.