103 resultados para STATIONARY SECTORIAL SAMPLER
Resumo:
The present work reviews recent advances in the preparation of new reversed phase packing materials such as sterically protected, bidentate, hybrid organic-inorganic and monolithic phases and phases containing embedded polar groups. The bonding chemistry involved in the preparation of these phases as well as their advantages over conventional C8 and C18 reversed phases are discussed. Understanding the reasons behind the development of these newer column packings helps analysts select the best stationary phase for a given application.
Comparação de duas metodologias de amostragem atmosférica com ferramenta estatística não paramétrica
Resumo:
In atmospheric aerosol sampling, it is inevitable that the air that carries particles is in motion, as a result of both externally driven wind and the sucking action of the sampler itself. High or low air flow sampling speeds may lead to significant particle size bias. The objective of this work is the validation of measurements enabling the comparison of species concentration from both air flow sampling techniques. The presence of several outliers and increase of residuals with concentration becomes obvious, requiring non-parametric methods, recommended for the handling of data which may not be normally distributed. This way, conversion factors are obtained for each of the various species under study using Kendall regression.
Resumo:
The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.
Resumo:
A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.
Resumo:
Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.
Resumo:
A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.
Resumo:
There is great interest nowadays in the use of preparative liquid chromatography as an effective tool for the production of enantiomerically pure, or enriched, compounds for the pharmaceutical industry. To make the chromatographic process economically attractive, attention is now focused on the choice of the chromatographic operating mode to minimize eluent consumption and to maximize productivity. Among the alternatives to the traditional batch chromatography, attention is now shifting towards simulated moving bed (SMB) technologies and a review covering the latest developments in this area seems timely. Several aspects of this important analytical technique are presented and details concerning the SMB technology for process optimization are outlined.
Resumo:
Based on a specially created mass spectral database utilizing 23 tetradecenyl and 22 hexadecenyl acetate standards along with Kóvats retention indices obtained on a very polar stationary phase [poly (biscyanopropyl siloxane)] (SP 2340), (Z)-9-hexadecenyl acetate, (Z)-11-hexadecenyl acetate and (E)-8-hexadecenyl acetate were identified in active pheromone extracts of Elasmopalpus lignosellus. This identification was more efficient than our previous study using gas chromatography/mass spectrometry with a dimethyl disulfide derivative where we could only identify the first two acetates. The acetate composition of the pheromone gland differed from region to region in Brazil and from that from the Tifton (GA, USA) population, suggesting polymorphism or a different sub-species.
Resumo:
An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.
Resumo:
Chromatography is a means of separating mixtures into their several components. TLC, mainly a liquid/solid process, is one of the separation techniques most often used. It is indispensable in laboratories dealing with natural products, organic and analytical chemistry. Commercial chromatography plates are offered at relatively high cost. In this work the construction of a hand-operated plate coater of stationary phases of low cost and good reproducibility is described to be used in teaching laboratories and research.
Resumo:
This paper presents a simple and practical thermogravimetric method for determining the layer thickness of immobilized polymer stationary phases used in reversed-phase high-performance liquid chromatography. In this method, the weight loss of different polysiloxanes immobilized onto chromatographic supports, determined over the temperature range 150-650 ºC, demonstrated excellent agreement with the sum of carbon and hydrogen content obtained by elemental analysis. The results presented here suggest that the thermogravimetric procedure is an accurate and precise method to determine the polymeric material content on polymer-coated stationary phases.
Resumo:
The assembly of a photochemical reactor with six fluorescent lamps, used for photopolymerizations is described. This chamber presents a mobile support, allowing the placement of samples at different heights and a safety lock that interrupts the radiation, if it is opened during operation. The mirrored internal walls avoid the dispersion and non-uniform distribution of light. There is no high heating because the own character of the used lamps. All parts could be purchased in commerce with less than U$ 150,00. This reactor was successfully used for monolithic stationary phase photopolymerization.
Resumo:
In this work the separation of the chiral anesthetic compounds ketamine and bupivacaine was development using two chiral stationary phases (CSP). Ketamine enantiomers were well separate in the polysaccharide-based CSP (microcrystalline cellulose triacetate - MCTA) while bupivacaine in the tartardiamide-based CSP (Kromasil CHI-TBB). In both cases, the effect of temperature was investigated under analytical conditions. An improvement in the separation performance with temperature was observed. Thermodynamic parameters were evaluated by the van't Hoff plot. We concluded that enthalpic effects controlled the retention in these chiral columns. The enantiomers of ketamine and bupivacaine were separated under overloaded conditions with a good performance.
Resumo:
Aerosol size distributions from 6 to 700 nm were measured simultaneously at an urban background site and a roadside station in Oporto. The particle number concentration was higher at the traffic exposed site, where up to 90% of the size spectrum was dominated by the nucleation mode. Larger aerosol mode diameters were observed in the urban background site possibly due to the coagulation processes or uptake of gases during transport. Factor analysis has shown that road traffic and the neighbour stationary sources localised upwind affect the urban area thought intra-regional pollutant transport.
Resumo:
The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.