130 resultados para Remaining flow
Resumo:
The remaining phosphorus (Prem) has been used for estimating the phosphorus buffer capacity (PBC) of soils of some Brazilian regions. Furthermore, the remaining phosphorus can also be used for estimating P, S and Zn soil critical levels determined with PBC-sensible extractants and for defining P and S levels to be used not only in P and S adsorption studies but also for the establishment of P and S response curves. The objective of this work was to evaluate the effects of soil clay content and clay mineralogy on Prem and its relationship with pH values measured in saturated NaF solution (pH NaF). Ammonium-oxalate-extractable aluminum exerts the major impacts on both Prem and pH NaF, which, in turn, are less dependent on soil clay content. Although Prem and pH NaF have consistent correlation, the former has a soil-PBC discriminatory capacity much greater than pH NaF.
Resumo:
This study was carried out to assess the genetic variability of ten "cagaita" tree (Eugenia dysenterica) populations in Southeastern Goiás. Fifty-four randomly amplified polymorphic DNA (RAPD) loci were used to characterize the population genetic variability, using the analysis of molecular variance (AMOVA). A phiST value of 0.2703 was obtained, showing that 27.03% and 72.97% of the genetic variability is present among and within populations, respectively. The Pearson correlation coefficient (r) among the genetic distances matrix (1 - Jaccard similarity index) and the geographic distances were estimated, and a strong positive correlation was detected. Results suggest that these populations are differentiating through a stochastic process, with restricted and geographic distribution dependent gene flow.
Resumo:
The aim of this work was to evaluate the association between milk flow, teat morphological measurements and subclinical mastitis prevalence in Gir cows. Eighty cows in the 2nd and 3rd lactations, with 90 to 200 days of lactation, were divided according to milk flow during milking into fast or slow groups. Teat morphometry was assessed by ultrasound scanning of the right anterior teat and external measurements. Milk samples were collected for somatic cells count (SCC) and microbiological culture. The effect of milk flow during milking was evaluated by analysis of variance of milk yield, SCC, morphometry and external measurements. The association of morphometry and external measurements of the teats with the SCC and microorganisms found in milk were analysed. Milk flow was significantly correlated to milk production. Gir cows with slower milk flow had longer teat canal and greater milk yield, in comparison to cows with fast milk flow. Teat-end to floor distance influenced SCC of Gir cows. Prevalence of subclinical mastitis and the type of mastitis-causing pathogens were not affected by milk flow during milking
Resumo:
Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.
Is there any influence of breastfeeding on the cerebral blood flow? A review of 256 healthy newborns
Resumo:
OBJECTIVE: To investigate whether breastfeeding influence the cerebral blood-flow velocity. MATERIALS AND METHODS: The present study included 256 healthy term neonates, all of them with appropriate weight for gestational age, 50.8% being female. Pulsatility index, resistance index and mean velocity were measured during breastfeeding or resting in the anterior cerebral artery, in the left middle cerebral artery, and in the right middle cerebral artery of the neonates between their first 10 and 48 hours of life. The data were analyzed by means of a paired t-test, Brieger's f-test for analysis of variance and linear regression, with p < 0.01 being accepted as statistically significant. RESULTS: Mean resistance index decreased as the mean velocity increased significantly during breastfeeding. Pulsatility index values decreased as much as the resistance index, but in the right middle cerebral artery it was not statistically significant. CONCLUSION: Breastfeeding influences the cerebral blood flow velocities.
Resumo:
Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001). As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.
Resumo:
Objective To evaluate the association of Doppler of uterine artery and flow-mediated dilation of brachial artery (FMD) in the assessment of placental perfusion and endothelial function to predict preeclampsia. Materials and Methods A total of 91 patients considered as at risk for developing preeclampsia were recruited at the prenatal unit of the authors' institution. All the patients underwent FMD and Doppler of uterine arteries between their 24th and 28th gestational weeks. Calculations of sensitivity and specificity for both isolated and associated methods were performed. Results Nineteen out of the 91 patients developed preeclampsia, while the rest remained normotensive. Doppler flowmetry of uterine arteries with presence of bilateral protodiastolic notch had sensitivity of 63.1% and specificity of 87.5% for the prediction of preeclampsia. Considering a cutoff value of 6.5%, FMD showed sensitivity of 84.2% and specificity of 73.6%. In a parallel analysis, as the two methods were associated, sensitivity was 94.2% and specificity, 64.4%. Conclusion The association of Doppler study of uterine arteries and FMD has proved to be an interesting clinical strategy for the prediction of preeclampsia, which may represent a positive impact on prenatal care of patients considered as at high-risk for developing such a condition.
Resumo:
AbstractObjective:Longitudinal study with B-mode ultrasonography and Doppler ultrasonography of maternal kidneys and liver in low-risk pregnancy, to establish and quantify normality parameters, correlating them with physiological changes.Materials and Methods:Twenty-five pregnant women were assessed and selected to participate in the study, each of them undergoing four examinations at the first, second, third trimesters and postpartum.Results:Findings during pregnancy were the following: increased renal volume, pyelocaliceal dilatation with incidence of 45.4% in the right kidney, and 9% in the left kidney; nephrolithiasis, 18.1% in the right kidney, 13.6% in the left kidney. With pyelocaliceal dilatation, mean values for resistivity index were: 0.68 for renal arteries; 0.66 for segmental arteries; 0.64 for interlobar arteries; 0.64 for arcuate arteries. Without pyelocaliceal dilatation, 0.67 for renal arteries; 0.64 for segmental arteries; 0.63 for interlobar arteries; and 0.61 for arcuate arteries. Portal vein flow velocities presented higher values in pregnancy, with mean value for maximum velocity of 28.9 cm/s, and 22.6 cm/s postpartum. The waveform pattern of the right hepatic vein presented changes persisting in the postpartum period in 31.8% of the patients. Cholelithiasis was observed in 18.1% of the patients.Conclusion:Alterations in renal volume, pyelocaliceal dilatation, nephrolithiasis, cholelithiasis, changes in portal vein flow velocity, alterations in waveform pattern of the right hepatic vein, proved to be significant.
Resumo:
Abstract Objective: To determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and Methods: We evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm2, three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (N0) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: Low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment-induced salivary hypofunction in patients with head and neck cancer.
Resumo:
The aquatic humic substances (AHS) investigated in this study were conventionally isolated from Rio Negro waters - Amazonas State/Brazil by means of the collector XAD 8. A special five-stage tangential-flow ultrafiltration device was used for analytical fractionation of AHS. The fractionation patterns (6 fractions each) showed that metal traces remaining in AHS after their XAD 8 isolation have different size distributions. For instance, the major percentage of traces of Ni, Cu, Zn, Cd and Pb (determined using ICP-AES) was preferably complexed by molecules with relatively high molecular size (30-100 kDa) and the following complexation order was characterized: F2 >> F1 = F4 = F5 > F3 > F6. Moreover, the species formed between AHS and metals prepared by spiking, showed distribution patterns changing as a function of the complexation time (ageing process), indicating a slow transformation process and an inner rearrangements in the binding sites within the AHS molecules.
Resumo:
The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.
Resumo:
A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.
Resumo:
The modern stopped-flow reaction analyzer has shown high efficiency and flexibility, which provides outstanding sample economy with a dead-time of less than 1 ms. However the cost of the equipment imposes a serious restriction to many Brazilian scientists and teachers. In this work we describe the construction of a low-cost stopped-flow system coupled to a UV-Vis spectrophotometer. The performance of the system was checked by monitoring the kinetics of two reactions: the fading of phenolphthalein in aqueous alkaline solution and the chlorophyll a demetallation in acid medium. The apparatus showed reasonable efficiency with a dead-time of 0.3 to 0.5 s. The very good results obtained in these two illustrative processes show that the system is satisfactory for determining rate constants with mean reaction times ranging from seconds to minutes.
Resumo:
An evaluation of the performance of a continuous flow hydride generator-nebulizer for flame atomic absorption spectrometry was carried out. Optimization of nebulizer gas flow rate, sample acid concentration, sample and tetrahydroborate uptake rates and reductant concentration, on the As and Se absorbance signals was carried out. A hydrogen-argon flame was used. An improvement of the analytical sensitivity relative to the conventional bead nebulizer used in flame AA was obtained (2 (As) and 4.8 (Se) µg L-1). Detection limits (3σb) of 1 (As) and 1.3 (Se) µg L-1 were obtained. Accuracy of the method was checked by analyzing an oyster tissue reference material.
Resumo:
In the present work, the development of a method based on the coupling of flow analysis (FA), hydride generation (HG), and derivative molecular absorption spectrophotometry (D-EAM) in gas phase (GP), is described in order to determine total antimony in antileishmanial products. Second derivative order (D²224nm) of the absorption spectrum (190 - 300 nm) is utilized as measurement criterion. Each one of the parameters involved in the development of the proposed method was examined and optimized. The utilization of the EAM in GP as detection system in a continuous mode instead of atomic absorption spectrometry represents the great potential of the analytic proposal.