106 resultados para Graphite furnace atomic absorption spectrometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni) in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a) evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b) optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS) and by Electrothermal Atomic Absorption (ETAAS) in vegetable samples and (c) determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The NaCl- KCl system as fused-salt solvent for leaching has shown to have some advantages over traditional solvents. In this work the solubility of copper, nickel and cobalt oxide in this system, as impurities in manganese concentrate, was studied. The euthetic mixture of NaCl - KCl at 700ºC was used at several fusion times and the dissolved metals were determined by Atomic Absorption Spectrometry. The results have shown that in these conditions only copper was solubilized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

'Cachaça' is the Brazilian name for the spirit obtained from sugarcane. According to Brazilian regulations, it may be sold raw or with addition of sugar and may contain up to 5 mg/L of copper. Copper in "cachaça" was determined by titration with EDTA, using a homemade copper membrane electrode for end-point detection. It was found a pooled standard deviation of 0,057 mg/L and there was no significant difference between the results obtained by the potentiometric method and by flame atomic absorption spectrometry with standard addition. Among the 21 'cachaça' samples from 16 different brands analyzed, three overpassed the legal copper limit. For its characteristics of accuracy, precision, and speed, the potentiometric method may be employed advantageously in routine analysis, specially when low cost is a major concern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a system for electrochemical hydride generation using flow-injection and atomic absorption spectrometry to determine selenium in biological materials. The electrolytic cell was constructed by assembling two reservoirs, one for the sample and the other for the electrolytic solution separated by a Nafion membrane. Each compartment had a Pt electrode. The sample and electrolyte flow-rates, acidic media, and applied current were adjusted to attain the best analytical performance and ensure the membrane lifetime. The atomisation system used a T quartz tube in an air-LPG flame. The composition of the flame, the observation height, and the argon flow rate used to carry the hydrides were critically investigated. The system allowed to perform thirty determinations per hour with a detection limit of 10 mug L-1 of Se. Relative standard deviations were in general lower than 1.5% for a solution containing 20.0 and 34.0 mug L-1 of Se in a typical sample digest. Accuracy was assessed analysing the certified materials: rice flour (NIST-1568) from National Institute of Standard and Technology and dried fish (MA-A-2), whole animal blood (A-2/1974) from the International Atomic Energy Agency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the combination of low- and high-pressure flow systems for the determination of Magnesium, Calcium and Strontium by flame atomic absorption spectrometry (FAAS). In the low-pressure system a short C-18 RP column (length 0,5 cm) was utilized for the preconcentration/matrix separation step, xylenol orange was used as chelating agent and tetrabutylamonium acetate for ion pair formation. The hydraulic high pressure nebulization (HHPN) was used for sample transport and sample introduction in the high pressure system. The repeatabilities and detection limits for Mg, Ca and Sr were determined and compared with those obtained by pneumatic nebulization (PN). The results show that the detection limits obtained using the HHPN for Mg, Ca and Sr are between 1.5 to 2 times better than those obtained by PN when the signal transient was measured in area. The system presented a sampling frequency of 130 h-1 for direct determination of Mg, Ca or Sr in samples of saturated sodium chloride used in the production of chlorine and sodium hydroxide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review presents an updated overview of the trace element speciation by gas chromatography coupled with atomic absorption spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was evaluated the applicability of Langmuir, Freundlich and Temkin models to copper adsorption in three classes of soils. Fractions of each soil were added to test tubes containing growing concentrations of the metal in solution. The tubes were shaken and the copper concentrations were determined in the extracts by atomic absorption spectrometry (AAS). The models offered a good fit for the experimental data indicating that presence of silicated clay had high influence on copper sorption. The Langmuir isotherm showed high influence of the organic matter in the absorption phenomenon. It was evidenced the importance of further studies related to Temkin model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 mL of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to demonstrate the feasibility of slurry sampling for environmental studies, different methodologies were developed for Cu and Zn in antarctic limpets and Ni in river sediment with FAAS detection. Studies focusing particle size, acid concentration, slurry stability, selectivity, among others were carried out in order to define the better conditions for slurry analysis. A study related to the depth profile for Ni in the Atibaia River sediment was made after optimization conditions for this element. For accuracy check, certified reference material was used as well as decomposition with microwave oven.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nickel nanoparticles supported on amorphous silica ceramic matrix were synthesized by the polymeric precursor method. The nanostructure was characterized by NMR, BET, XRD, SEM, TEM, and flame atomic absorption spectrometry techniques. It was observed a dependence of the crystallite size on the thermal annealing, under a N2 atmosphere. The materials presented a high catalytic activity and selectivity upon the beta-pinene hydrogenation reaction. The magnetic hystereses were also correlated with the morphology of the processed material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a review on internal standardization in atomic absorption spectrometry with emphasis to the systematic and random errors in atomic absorption spectrometry and applications of internal standardization in flame atomic absorption spectrometry and electrothermal atomic absorption spectrometry. The rules for selecting an element as internal standard, limitations of the method, and some comments about the application of internal standardization in atomic absorption spectrometry and the future of this compensation strategy are critically discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The toxicity of the major As species present in the environment justifies the effort for quantifying the element in environmental organic samples, which can vary from animal and vegetal tissues to coal and industrial residues. This paper comments about the applicability of the O2 bomb digestion, as a general procedure for all environmental organic materials. A rapid and straightforward method is suggested, which consists in burning the sample in the bomb at high O2 pressure, dissolving the vapours in diluted HNO3 and determining As in the resulting solution by atomic absorption spectrometry with electrothermal atomization. The method was applied to certified materials and plant samples.