71 resultados para Estructura atòmica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric materials are widely used in the chemical industry and are part of our daily lives. Inorganic species may be added to them as additives, anti-oxidizing agents, stabilizers, plasticizers, colorants and catalysts and may be present in a wide range of concentrations. Their determination demands the development of analytical methods considering different kinds of polymeric materials, their composition and the final use of the material. Although many different analytical techniques may be used, this review emphasizes those based on atomic absorption and emission spectrometry. Solid sampling techniques and digestion methods are described and discussed and compared considering published results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper present an overview of way covered for the spectrometry of atomic absorption (AAS), tracing a line of the historical events in its development and its establishment as a multielement technique. Additionally, the efforts carried by through several researchers in the search for the instrumental evolution, the advances, advantages, limitations, and trends of this approach are related. Several works focusing its analytical applications are cited employing simultaneous multielement determination by flame (FAAS) and/or graphite furnace (GF AAS), and fast sequential multielement determination using FAAS are reported in the present review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with paint decomposition methods for major, minor and trace elements determination. Three methods were investigated: (1) decomposition in closed quartz vessel and heating in microwave oven; (2) decomposition in open vessel using HNO3 and ashing, following the ASTM D 3335-85a method; and (3) decomposition in open vessel using HNO3 + HF and ashing. Paints of different types and colours were analyzed, in which several elements were determined using inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was observed that method (1) is appropriate for trace, minor and major elements determination, while method (3) is appropriate for Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microcystins are non-ribosomal peptides that must be detected for its health concern. Here, microcystin LR and its specific antibody were respectively tethered to the substrate and to the tip of an atomic force microscope, after surface functionalization using 3-aminopropyltriethoxysilane and glutaraldehyde. Functionalization was confirmed comparing topographic images taken on bare and modified tips. Force versus distance curves were successfully used to measure the specific antibody-antigen interactions comparing with a control in which microcystin was initially blocked by incubation with free antibodies. The results showed unequivocally the specific recognition of MLR, suggesting that this method could be useful for biosensor development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chicken meat is largely consumed in human nutrition and it is produced in extremely large scale in some countries, including Brazil. In this work graphite furnace atomic absorption spectrometry was used for determination of arsenic in chicken and chicken production-related samples. These samples were digested employing a microwave-assisted procedure in closed vessels using a 7 mol L-1 nitric acid solution plus concentrated hydrogen peroxide. The concentration range of total As determined in chicken production-related samples varied from 1.30 to 29.8 mg kg-1 of As. The detection and quantification limits reached were 0.055 and 0.182 mg kg-1, respectively (n = 15).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levels of Ca, Mg, Fe, Zn, Cu and Mn were determinated by FAAS in the tea and dry matter from senescent leaf from Montrichardia linifera, plant used in folk medicine Amazon. The content of these metals that are transferred of the leaf to the infusions have presented significant reductions, however, the Mn values in the infusion may exceed the tolerable daily intake (11 mg) if consumption of this tea is greater than 1.0 L per day. So the tea of senescent leaves of M. linifera may be considered as a toxic beverage and thus its use is not advised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of methods for the determination of Pb and Mn in fishes by GF AAS after solubilization with tetramethylamonium hidroxide. The optimization of the operational conditions and the choice of modifier were made using multivariated optimization. Analytical Figures of Merit were adequately to propose. The Limit of Quantification obtained were 150 and 18.5 µg kg-1 to Mn and Pb, respectively. No significant difference was found between the slope values obtained for the aqueous and standard addition calibration curves. The D.P.R. was always lower than 12% and the analysis of the SRM NRCC TORT2 showed 80-120% of recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of methods in micro-scale for the determination of K, Mg, Na and Zn in meat by atomic spectrometry techniques. The limits of detection (LOD) for K and Na by microdigestion were 0.18 and 0.20 mg g-1, respectively whereas LOD for Mg and Zn by microsolubilization with TMAH were 2.40 and 18.4 µg g-1, respectively. The RSD values were lower than 6.0% and the CRMs analyzed showed values with 95% agreement. The proposed methods are simple, fast and use small amounts of sample (around 10 mg) yet do not require special equipment for sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.