90 resultados para Controller medications


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract OBJECTIVE To identify the factors associated with involuntary hospital admissions of technology-dependent children, in the municipality of Ribeirão Preto, São Paulo State, Brazil. METHOD A cross-sectional study, with a quantitative approach. After an active search, 124 children who qualified under the inclusion criteria, that is to say, children from birth to age 12, were identified. Data was collected in home visits to mothers or the people responsible for the children, through the application of a questionnaire. Analysis of the data followed the assumptions of the Generalized Linear Models technique. RESULTS 102 technology-dependent children aged between 6 months and 12 years participated in the study, of whom 57% were male. The average number of involuntary hospital admissions in the previous year among the children studied was 0.71 (±1.29). In the final model the following variables were significantly associated with the outcome: age (OR=0.991; CI95%=0.985-0.997), and the number of devices (OR=0.387; CI95%=0.219-0.684), which were characterized as factors of protection and quantity of medications (OR=1.532; CI95%=1.297-1.810), representing a risk factor for involuntary hospital admissions in technology-dependent children. CONCLUSION The results constitute input data for consideration of the process of care for technology-dependent children by supplying an explanatory model for involuntary hospital admissions for this client group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the early 1990s numerous clinical trials with antileukotriene drugs confirmed the hypothesis that cysteinyl leukotrienes are important bronchoconstrictor agents in asthma. Newly released"antiasthmatic medications include antileukotriene agents which function either by blocking the interaction of leukotrienes with receptors or by inhibiting leukotriene synthesis. Representatives of cysteinyl leukotriene receptors antagonists are zafirlukast (7), montelukast (8) and pranlukast (9). The bronchodilator efficacy and antiinflammatory property of antileukotriene drugs provided the main impetus behind their introduction as the first novel class of asthma therapy in more than 20 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A microcontrolled, portable and inexpensive photometer is described. It uses six light-emitting diodes (LEDs) as radiation sources and a phototransistor as detector, as well as a microcontroller (PIC - Programmable Controller of Interruption). This device provided total autonomy to the proposed photometer, which was successfully applied to determination of Fe2+ in ferrous syrups and of seven clinical biochemical parameters. As the components are cheap (~U$30.00) and easy to find, the proposed photometer is an economical alternative for routine chemical analyses in small laboratories, for research and teaching. Being portable and microcontrolled, it allows doing field chemical analyses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two methods for the determination of Ivermectin in veterinarian medications were developed and compared. One of the methods was based on UV spectrometry and the other on HPLC-UV. The former method was shown to be positively biased regarding the nominal concentrations of Ivermectin in different medications. The method of standard addition was unable to correct this bias, indicating significant matrix effects. The HPLC-UV method showed good linearity, throughput, recovery and limits of detection and quantitation adequate for its application in the evaluation of Ivermectin in medications. Several medications were evaluated and good agreement between our results and their nominal concentrations was found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fuzzy logic admits infinite intermediate logical values between false and true. With this principle, it developed in this study a system based on fuzzy rules, which indicates the body mass index of ruminant animals in order to obtain the best time to slaughter. The controller developed has as input the variables weight and height, and as output a new body mass index, called Fuzzy Body Mass Index (Fuzzy BMI), which may serve as a detection system at the time of livestock slaughtering, comparing one another by the linguistic variables "Very Low", "Low", "Average ", "High" and "Very High". For demonstrating the use application of this fuzzy system, an analysis was made with 147 Nellore beeves to determine Fuzzy BMI values for each animal and indicate the location of body mass of any herd. The performance validation of the system was based on a statistical analysis using the Pearson correlation coefficient of 0.923, representing a high positive correlation, indicating that the proposed method is appropriate. Thus, this method allows the evaluation of the herd comparing each animal within the group, thus providing a quantitative method of farmer decision. It was concluded that this study established a computational method based on fuzzy logic that mimics part of human reasoning and interprets the body mass index of any bovine species and in any region of the country.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of cold storage chambers contributes largely to the quality and longevity of stored products. In recent years, it has been intensified the study of control strategies in order to decrease the temperature change inside the storage chamber and to reduce the electric power consumption. This study has developed a system for data acquisition and process control, in LabVIEW language, to be applied in the cooling system of a refrigerating chamber of 30m³. The use of instrumentation and the application developed fostered the development of scientific experiments, which aimed to study the dynamic behavior of the refrigeration system, compare the performance of control strategies and the heat engine, even due to the controlled temperature, or to the electricity consumption. This system tested the strategies for on-off control, PID and fuzzy. Regarding power consumption, the fuzzy controller showed the best result, saving 10% when compared with other tested strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to model mathematically and to simulate the dynamic behavior of an auger-type fertilizer applicator (AFA) in order to use the variable-rate application (VRA) and reduce the coefficient of variation (CV) of the application, proposing an angular speed controller θ' for the motor drive shaft. The input model was θ' and the response was the fertilizer mass flow, due to the construction, density of fertilizer, fill factor and the end position of the auger. The model was used to simulate a control system in open loop, with an electric drive for AFA using an armature voltage (V A) controller. By introducing a sinusoidal excitation signal in V A with amplitude and delay phase optimized and varying θ' during an operation cycle, it is obtained a reduction of 29.8% in the CV (constant V A) to 11.4%. The development of the mathematical model was a first step towards the introduction of electric drive systems and closed loop control for the implementation of AFA with low CV in VRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to the importance of the environment on animal production and thus environmental control, the study aims to build a system for monitoring and control the meteorological variables, temperature and relative humidity, low cost, which can be associated with an evaporative cooling system (ECS). The system development included all the stages of assembly, test and laboratory calibration, and later the validation of the equipment carried in the field. The validation step showed results which allowed concluding that the system can be safely used in the monitoring of these variables. The controller was efficient in management of the microclimate in the waiting corral and allowed the maintenance of the air temperature within the comfort range for dairy cattle in pre-milking with averaged 25.09 ºC during the afternoon. The equipment showed the lower cost (R$ 325.76) when compared to other middle market (R$ 450.00).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study shows the development, simulation and actual implementation of a closed-loop controller based on fuzzy logic that is able to regulate and standardize the mass flow of a helical fertilizer applicator. The control algorithm was developed using MATLAB's Fuzzy Logic Toolbox. Both open and closed-loop simulations of the controller were performed in MATLAB's Simulink environment. The instantaneous deviation of the mass flow from the set point (SP), its derivative, the equipment´s translation velocity and acceleration were all used as input signals for the controller, whereas the voltage of the applicator's DC electric motor (DCEM) was driven by the controller as output signal. Calibration and validation of the rules and membership functions of the fuzzy logic were accomplished in the computer simulation phase, taking into account the system's response to SP changes. The mass flow variation coefficient, measured in experimental tests, ranged from 6.32 to 13.18%. The steady state error fell between -0.72 and 0.13g s-1 and the recorded average rise time of the system was 0.38 s. The implemented controller was able to both damp the oscillations in mass flow that are characteristic of helical fertilizer applicators, and to effectively respond to SP variations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case of gastrocolic fistula(GCF) in a patient with duodenal stenosis who had previously undergone gastroenteric anastomosis is reported. The patient went through hemigastrectomy, partial colectomy and segmental enterectomy with bloc resection. Reconstruction was carried out through Billroth II gastrojejunostomy, jejunojejunostomy and end-to-end anastomosis of the colon. The patient had good post-operative evolution and was discharged from hospital seven days after surgery. GCF should be suspected in patients presenting weight loss, diarrhea and fecal vomiting, mainly with history of peptic ulcer surgery, gastric or colonic malignancy and use of steroidal and nonsteroidal antiinflamatory drugs. Barium enema is the choice test for diagnosis, however, the benign or malignant nature of the lesion should always be evaluated through high digestive endoscopy. Clinical treatment with oral H2-antagonists and discontinuing ulcerogenic medications might be indicated in some cases; surgical treatment is indicated in cases of malignant disease and might be indicated in cases of peptic disease as it treats GCF and also the baseline disease. Some advise upwards colostomy at first. The most used technique is bloc resection, including the fistulous tract, hemigastrectomy and partial colectomy. Gastrectomy, fistulous tract excision and colon suturing may be performed in some cases. The mortality rate is related to metabolic disorders and the recurrence with the use of antiinflammatory drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the effects of topical policresulen and cinchocaine in the postoperative pain behavior of open hemorrhoidectomy.METHODS: We conducted a prospective, double-blinded, controlled study. The control group received the usual guidelines with oral medications. The topical treatment group received, in addition, the application of the ointment and was comprised of two subgroups (policresulen + cinchocaine, and placebo). Pain intensity was recorded with the visual analogue scale.RESULTS: 43 patients were operated on: control group - n = 13, one excluded; placebo - n = 15; and policresulen + cinchocaine - n = 15. The mean age was 45.98 years and 37.2% were men. The average pain intensity was 4.09 (immediate postoperative), 3.22 (hospital discharge), 5.73 (day 1) , 5.77 (day 2), 5.74 (day 3), 5.65 (day 7), 5.11 (day 10), 2.75 (day 15) and 7.70 (first bowel movement), with no difference between groups in all periods.CONCLUSION: This study showed no reduction in pain after hemorrhoidectomy with the use of topical policresulen and cinchocaine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Higher travel speeds of rail vehicles will be possible by developing sophisticated top performance bogies having creep-controlled wheelsets. In this case the torque transmission between the right and the left wheel is realized by an actively controlled creep coupling. To investigate hunting stability and curving capability the linear equations of motion are written in state space notation. Simulation results are obtained with realistic system parameters from industry and various controller gains. The advantage of the „creep-controlled wheelset" is discussed by comparison the simulation results with the dynamic behaviour of the special cases „solid-axle wheelset" and „loose wheelset" (independent rotation of the wheels). The stability is also investigated with a root-locus analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increasing complexity of controller systems, applied in modern passenger cars, requires adequate simulation tools. The toolset FASIM_C++, described in the following, uses complex vehicle models in three-dimensional vehicle dynamics simulation. The structure of the implemented dynamic models and the generation of the equations of motion applying the method of kinematic differentials is explained briefly. After a short introduction in methods of event handling, several vehicle models and applications like controller development, roll-over simulation and real-time-simulation are explained. Finally some simulation results are presented.