A flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of vancomycin hydrochloride, C66H75Cl2N9O24.HCl (HVCM), based on the reaction with copper (II) ions, is presented. HVCM forms a lilac-blue complex with copper ions at pH≅4.5 in aqueous solutions, with maximum absorption at 555 nm. The detection limit was estimated to be about 8.5×10-5 mol L-1; the quantitation limit is about 2.5×10-4 mol L-1 and about 30 determinations can be performed in an hour. The accuracy of the method was tested through recovery procedures in presence of four different excipients, in the proportion 1:1 w/w. The results were compared with those obtained with the batch spectrophotometric and with the HPLC methods. Statistical comparison was done using the Student's procedure. Complete agreement was found at a 0.95 significance level between the proposed flow injection and the batch spectrophotometric methods, which present similar precision (RSD: 2.1 % vs. 1.9%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of total sulfur in the form of sulfate, precipitated in the form of barium sulfate, is presented. The method was applied to biodiesel, to plant leaves and to natural waters analysis. The analytical signal (S) correlates linearly with sulfate concentration (C) between 20 and 120 ppm, through the equation S=-1.138+0.0934 C (r = 0.9993). The experimentally observed limit of detection is about 10 ppm. The mean R.S.D. is about 3.0 %. Real samples containing sulfate were analyzed and the results obtained by the FI and by the reference batch turbidimetric method using the statistical Student's t-test and F-test were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diesel fuel is used widely in Brazil and worldwide. On the other hand, the growing environmental awareness leads to a greater demand for renewable energy resources. Thus, this study aimed to evaluate the use of different blends of soybean (Glycine max) methyl biodiesel and diesel in an ignition compression engine with direct injection fuel. The tests were performed on an electric eddy current dynamometer, using the blends B10, B50 and B100, with 10; 50 e 100% of biodiesel, respectively, in comparison to the commercial diesel B5, with 5% of biodiesel added to the fossil diesel. The engine performance was analyzed trough the tractor power take off (PTO) for each fuel, and the best results obtained for the power and the specific fuel consumption, respectively, were: B5 (44.62 kW; 234.87 g kW-1 h-1); B10 (44.73 kW; 233.78 g kW-1 h-1); B50 (44.11 kW; 250.40 g kW-1 h-1) e B100 (43.40 kW; 263.63 g kW-1 h-1). The best performance occurred with the use of B5 and B10 fuel, without significant differences between these blends. The B100 fuel showed significant differences compared to the other fuels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the K2O distribution uniformity by surface drip irrigation at Universitat Politecnica de Valencia, Valencia, Spain (39º 29′ N, 0º 23′ W, 20 m). The irrigation was performed by drip lines with not-compensated emitters, spaced 0.3 m. The fertigation was realized using a fertilizer injector pump of electric action with injection of 0.25 h. The experimental design used completely randomized blocks with five treatments and four replications. The treatments consisted of injection in five distances, located at 10; 20; 30; 40; 50 m of the first drip line. Samples were collected in emitters located at the start, at 1/3, at 2/3 and at the end of the drip lines. The nutrient concentration was determined by flame spectrophotometry. The Christiansen's uniformity coefficients (CUC), of distribution (DUC), of statistical (SUC) and of emission (eUC) were estimated. The K2O concentration and distribution decreased linearly with the increase of the injection distance. In all treatments, the CUC, SUC and DUC were described as 'excellent'. The eUC was described as 'recommended' only at smaller injection distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The autors present a case of bilateral vulvar defects after abrasion of malignant skin neoplasm, reconstructed with a gluteal-fold perforator flap, resulting in a successful outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the epidemiological profile and the operative complications of patients undergoing gynecological operations for benign diseases in a tertiary public hospital in the state of Roraima, Brazil. Methods: We conducted a retrospective survey through the analysis of 518 records of patients submitted to gynecological operations between January and June 2012. We included the three major operations during this period (n = 175): hysterectomy, colpoperineoplasty and suburethral sling placement. We excluded 236 cases of tubal ligation and 25 cases where it was not possible to access to medical records. Results: The mean age was 47.6 years; the education level of most patients was completed junior high (36.6%); 77% were from the State capital, 47.4% were in stable relationships and 26.3% were housewives. The majority of patients had given birth three or more times (86.6%), with previous vaginal delivery in 50.2%, and cesarean delivery, 21%. The main diagnostic indications for surgical treatment were uterine myoma (46.3%), urinary incontinence (27.4%) and genital dystopias (17.7%). We found three cases (1.7%) of high-grade intraepithelial lesions on Pap smear. The most common procedure was total hysterectomy (19.8%), 15.5% vaginally. The most common complication was wound infection (2.2%). Conclusion: Women undergoing gynecological operations due to benign disease had a mean age of 47 years, most had levels of basic education, came from the capital, were in stable relationships, predominantly housewives, multiparous and showed low operative complication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dichorionic twin pregnancy with complete hydatidiform mole and coexistent fetus is a rare and challenging situation, whose pathogenesis has not been yet fully understood. We present a case of a 39-year-old woman who underwent intracytoplasmic sperm injection with two embryos transfer. The 12-week gestation ultrasound examination revealed normal fetus and placenta with features of hydatidiform mole, leading to pregnancy termination. Autopsy and histological examinations diagnosed a complete mole coexisting with a normal fetus, and the genetic analysis showed a diploid fetus with biparental genome and molar tissue with paternal diploidy. This case highlighted that complete molar pregnancies may still occur even though pregnancy is achieved after intracytoplasmic sperm injection. A review of the literature was performed by collecting data from the few similar reported cases and by commenting on the pathogenesis of this rare condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An outbreak of salinomycin poisoning in rabbits is described. At least 27 out of 2,000 rabbits reared on a farm died after the coccidiostatic drug sulfaquinoxaline was substituted by salinomycin in the feed. An average of 26.9ppm salinomycin was detected in the ration given to the rabbits. Clinical signs included anorexia, apathy and bradykinesia, which progressed to incoordination and recumbency. Gross lesions consisted of pale areas in the skeletal muscles. The histopathological findings showed severe necrotic degenerative myopathy in association with infiltration of neutrophils and macrophages. One rabbit exhibited similar alterations in the myocardium. Mineralization was observed in the affected skeletal muscles in some cases. In order to verify if the poisoning was due to salinomycin, 20 rabbits were divided into five groups and a ration containing the drug at doses of 10, 25, 50, 75 and 100ppm was given. The administration of doses higher than 50ppm resulted in manifestation of the clinical signs seen in the outbreak of poisoning. It was concluded, that probably an error related to the mixture of salinomycin in the feed was the cause of deaths in the spontaneous outbreak of poisoning on the rabbit farm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of bovine tuberculosis aims to identify the immune response against mycobacterial antigens. Although Single Intradermal Comparative Cervical Tuberculin test (SICCT) is broadly used for first identification of the disease, the performance of ELISAs has been investigated for diagnosis improvement. The present study expected to find out the influence of intradermal skin tests on the results of ELISAs using the recombinant proteins MPB70 and MPB83 as antigens on cows from a naturally infected herd. Results were analyzed by the F-test, Mann-Whitney and Friedman tests Although comparable to both proteins, results showed that positive animals presented a tendency of augment reactivity to MPB70, representing a tendency for a booster effect, but not to MPB83.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract An outbreak of Closantel intoxication in sheep in Uruguay is described. The outbreak occurred in a group of 1300 weaning lambs treated orally with a 10% solution of Closantel. One hundred forty eight lambs showed clinical signs of intoxication and 14 died. The clinical signs included mydriasis, nystagmus, and negative pupillary reflex, bilateral blindness, bump into objects, and lateral movement of the head. No macroscopic lesions were observed. The histological lesions of the retina were cytoplasmic vacuolization in ganglion cells and in cells of the inner and outer nuclear layers with different degrees of atrophy. Vacuolization and axonal degeneration were observed in the optic nerve, with multifocal areas of fibrosis and infiltration by lymphocytes and Gitter cells. To reproduce the intoxication, four sheep were given two, four and 10 times the therapeutic dose of Closantel (0.1g/kg of BW). Only the animals receiving 10 times the recommended dose showed clinical signs. The histological examination of the lesions in experimental sheep showed similar results to those described in the accidental outbreak, except for the absence of optic nerve fibrosis and inflammation, characterizing an acute phase. Axonal myelin sheaths loss, fibroblasts and collagen fibers were observed in the ultrastructural study of the optic nerve of accidental intoxicated animals. The optic nerve of experimentally intoxicated animals had vacuoles that separated the myelin sheaths of axons. To prevent outbreaks it is suggested to weigh the animals before Closantel administration to avoid errors in dose calculation.